In the field of explosive reactions, there is a type of explosive effect that lacks a sufficient database and reproducible experiments regarding biomechanics. It concerns the primary explosive effect. It is defined as pure shock wave of the explosion. The physical behavior of the shock wave when interacting with different types of tissue and, in particular, the subsequent transitions of the shock wave, have barely been investigated. The transition of the shock wave into other materials is the focus of the research Therefore, the aim of the investigations is the development of a multidisciplinary method to investigate shock wave behavior in various generic tissue simulants under the most reproducible conditions possible with realistic loads in an experimental test series with short set-up times. An autoclave is used to generate the pressure waves. A simplified torso model consisting of ballistic gelatin is used as a simulant.
In this paper, the influence of protective equipment on the pressure load in the tissue simulant is investigated. For this purpose, consecutive test setups are used. First, the behavior of ballistic gelatin as a tissue simulant is investigated. Then, the simplified torso model is covered with typical combat clothing consisting of four layers.
Afterwards a currently used UHMWPE ballistic protective plate is placed in front of the simplified torso model.
Finally, the combat clothing and the protective plate are examined in combination. Three cast-in pressure sensors are used as measuring devices, as well as an acceleration sensor attached to the protective plate.
The experiments show that the maximum overpressure in a model rotected by combat clothing and the protective plate can be reduced by 95%. However, the propagation speed of the shock wave within the simplified torso model increases from 1535.5 m/s to 2204.5 m/s. This shows that even protective equipment, which is not primarily intended to protect against blast, offers a significant reduction in the pressure load in the protected area. On the one hand it is caused by the media transition from air to PE and the resulting higher reflection of the acceleration of the transmitted wave within the simulant. On the other hand, it is also reduced due to the damping and dispersion caused by the clothing layers.
In the field of explosive reactions, there is a type of explosive effect that lacks a sufficient database and reproducible experiments regarding biomechanics. It concerns the primary explosive effect. It is defined as pure shock wave of the explosion. The physical behavior of the shock wave when interacting with different types of tissue and, in particular, the subsequent transitions of the shock wave, have barely been investigated. The transition of the shock wave into other materials is the focus of the research Therefore, the aim of the investigations is the development of a multidisciplinary method to investigate shock wave behavior in various generic tissue simulants under the most reproducible conditions possible with realistic loads in an experimental test series with short set-up times. An autoclave is used to generate the pressure waves. A simplified torso model consisting of ballistic gelatin is used as a simulant. In this paper, the influence of protective equipment on the pressure load in the tissue simulant is investigated. For this purpose, consecutive test setups are used. First, the behavior of ballistic gelatin as a tissue simulant is investigated. Then, the simplified torso model is covered with typical combat clothing consisting of four layers. Afterwards a currently used UHMWPE ballistic protective plate is placed in front of the simplified torso model. Finally, the combat clothing and the protective plate are examined in combination. Three cast-in pressure sensors are used as measuring devices, as well as an acceleration sensor attached to the protective plate. The experiments show that the maximum overpressure in a model protected by combat clothing and the protective plate can be reduced by 95%. However, the propagation speed of the shock wave within the simplified torso model increases from 1535.5 m/s to 2204.5 m/s. This shows that even protective equipment, which is not primarily intended to protect against blast, offers a significant reduction in the pressure load in the protected area. On the one hand it is caused by the media transition from air to PE and the resulting higher reflection of the acceleration of the transmitted wave within the simulant. On the other hand, it is also reduced due to the damping and dispersion caused by the clothing layers.
Explosionsverletzungen gehören zu den häufigsten Verletzungen bei militärischen Einsätzen. Während die Auswirkungen von Splittern, die als sekundäre Explosionsverletzungen eingestuft werden, durch die modernen ballistischen Körperschutzsysteme der Polizei und des Militärs minimiert werden konnten, stellen die Auswirkungen der Stoßwellenausbreitung im Körper als Teil des primären Explosionstraumas nach wie vor eine ernsthafte Bedrohung dar. Zusätzlich zu einzelnen einsatzbedingten Lastfällen liegt ein wissenschaftlicher Fokus auf besonders exponiertem Personal, z.B. aus den Einsatzbereichen „Taktische Zugangstechnik“, „Präzisionsschützenwesen“ oder Steilfeuerwaffen (Mörser). Repetitive mild traumatic brain injury (mTBI) können gesundheitliche Langzeitschädigungen wie und chronic traumatic encephalopathy (CTE) erzeugen.
Um einen Beitrag zur Erforschung der primären Explosionswirkungen zu leisten, hat die Bundeswehr in Zusammenarbeit mit dem Bundeswehrkrankenhaus Berlin und der Bundesanstalt für Materialforschung und -prüfung (BAM) ein interdisziplinäres wehrmedizinisches Sonderforschungsvorhaben eingerichtet. Ziel der geplanten Untersuchung ist die Entwicklung einer multidisziplinären Methode zur Analyse des Stoßwellenverhaltens in verschiedenen generischen Gewebesimulanzien, sowie Schutzmaterialien unter möglichst realitätsnahen und reproduzierbaren Bedingungen.
Für die Erzeugung reproduzierbarer Stoßwellen wurde ein Autoklav
(Druckbehälter) entwickelt, mit dem durch die detonative Umsetzung eines Acetylen-Sauerstoff-Gemisches gut reproduzierbare Druckwellen unter Freifeldbedingungen erzeugt werden können. Vorteile dieser Methode sind unter anderem die kurzen Rüstzeiten zwischen Versuchsdurchgängen, die Minimierung störender Einflüsse im Vergleich zu Stoßwellenrohren und die geringeren Sicherheitsanforderungen im Vergleich zur Anwendung von konventionellen Sprengstoffen. Das generische Torso-Modell besteht in seiner einfachsten Form aus einem mit Druck- und Beschleunigungssensoren instrumentierten Gelatineblock, welcher eine Simulanz für organisches Gewebe darstellt. Zur Untersuchung des Stoßwellenverhaltens wurden verschiedene Medien, wie Hohlkörper, Festkörper und Gewebesimulanzien differenter Dichte in das generische Torso-Modell eingebracht. Einen besonderer Untersuchungsschwerpunkt bildeten die Grenzbereiche zwischen den unterschiedlichen Medien. Des Weiteren wurde analysiert, wie sich verschiedene Schutzmaterialien auf das Stoßwellenverhalten auswirken und mit welchen veränderten Eigenschaften die Stoßwelle anschließend in die Gewebesimulanz einkoppelt.
Experimental Setup for the Reproducible Generation of Pressure Waves in Free Field Conditions
(2023)
The injuries caused by the primary blast are still poorly understood, especially in the torso region. To generate sufficiently large data sets, shock tubes are often used. However, these have some limitations, such as blockage, use of the exit jet, widening cross-sections, and scaling problems with respect to compressive strength and test objects. Therefore, it is appropriate to conduct experiments under free-field conditions, but tests with real explosives are often associated with long preparation and setup times as well as high safety requirements.
Therefore, this paper presents an experimental setup for the reproducible generation of blast waves under free-field conditions. This experimental setup aims to provide a test environment for a sufficiently large specimen to investigate the behaviour of the shock wave within the specimen, especially at the media interfaces. As an example of application, the influence of the primary explosive effect on protective equipment or on tissue simulants for the investigation of blast injuries can be mentioned. An autoclave is used as a shock wave generator. It has a volume of 0.065 m3 and is filled with a stoichiometric acetylene-oxygen gas mixture. The setup and turnaround time is approximately 30 minutes. The following factors have been selected as target variables for the optimization of the shock wave generator: reproducibility of the pressure wave, use-case-relevant positive phase duration and peak overpressure, a pressure curve characteristic corresponding to that of a military explosive under undisturbed free field conditions, and short setup times of the experimental setup. For this purpose, the experimental setup is presented in this paper. Several series of measurements are presented, showing the characteristics of the generated pressure wave. For the generated pressure wave, the classical pressure curve characteristics can be clearly recognized. A peak pressure of 92 kPa is reached at a distance of 1 m from the opening, and the first positive pressure phase lasts 1.17 ms. Furthermore, the pressure wave propagates in a hemispherical shape. The typical characteristics of the blast wave generated by the SWG have been demonstrated using the military explosive PETN. It is shown that the actual load case corresponds to about 70 g of PETN.
Experimental Setup for the Reproducible Generation of Pressure Waves in Free Field Conditions
(2023)
The injuries caused by the primary blast are still poorly understood, especially in the torso region. To generate sufficiently large data sets, shock tubes are often used. However, these have some limitations, such as blockage, use of the exit jet, widening cross-sections, and scaling problems with respect to compressive strength and test objects. Therefore, it is appropriate to conduct experiments under free-field conditions, but tests with real explosives are often associated with long preparation and setup times as well as high safety requirements.
Therefore, this paper presents an experimental setup for the reproducible generation of blast waves under free-field conditions. This experimental setup aims to provide a test environment for a sufficiently large specimen to investigate the behaviour of the shock wave within the specimen, especially at the media interfaces. As an example of application, the influence of the primary explosive effect on protective equipment or on tissue simulants for the investigation of blast injuries can be mentioned. An autoclave is used as a shock wave generator. It has a volume of 0.065 m3 and is filled with a stoichiometric acetylene-oxygen gas mixture. The setup and turnaround time is approximately 30 minutes. The following factors have been selected as target variables for the optimization of the shock wave generator: reproducibility of the pressure wave, use-case-relevant positive phase duration and peak overpressure, a pressure curve characteristic corresponding to that of a military explosive under undisturbed free field conditions, and short setup times of the experimental setup. For this purpose, the experimental setup is presented in this paper. Several series of measurements are presented, showing the characteristics of the generated pressure wave. For the generated pressure wave, the classical pressure curve characteristics can be clearly recognized. A peak pressure of 92 kPa is reached at a distance of 1 m from the opening, and the first positive pressure phase lasts 1.17 ms. Furthermore, the pressure wave propagates in a hemispherical shape. The typical characteristics of the blast wave generated by the SWG have been demonstrated using the military explosive PETN. It is shown that the actual load case corresponds to about 70 g of PETN.
Safety criteria for the transport of hydrogen in permanently mounted composite pressure vessels
(2019)
The recent growing of the net of hydrogen fuelling stations increases the demands to transport compressed hydrogen on road by tube-trailers in composite pressure vessels. As transport regulation the ADR is applicable in Europe and adjoined regions and used for national transport in EU. This regulation provides requirements based on the burst pressure of each individual pressure vessel, regardless the capabilities of the transported hydrogen and relevant consequences resulting from worst case scenarios. In 2012, BAM (German Federal Institute for Materials Research and Testing) introduced consequence-dependent requirements and established them in national requirements concerning the “UN service life checks” etc.) to consider the transported volume and pressure of gases. However, this results in a stringent requirement in case of using large pressure vessels (tubes) on tube-trailers. In the studies presented here, the key safety factors for using hydrogen trailers are identified and reviewed through some safety measures from some countries like Japan, USA and China. Subsequently, the risk, chance, failure consequences of using trailers are evaluated, in addition, the difficulties for approving huge pressure vessels (large tubes) are addressed. There, a maximum acceptable pressure-volume product is defined. Finally, a performance-based criterion for the balance of chance and risk of hydrogen trailers is suggested to add into regulations and consequently into standards for hydrogen trailers.
The presentation starts with the first agreement of making a national attempt for the introduction of a pV-limit for hydrogen transport. It explains aspects of the technical development, provides an impression of catastrophic incidents, and explains the difference between risk control and consequence limitation. Then the process of determining consequences and the result from the discussion at the UN-WG are explained. The next part summarises the approach for counting the number of impacted persons as a function of the model of pressure wave, the pressure peak, the limits of injured persons and the population density. Finally, the latest state of the discussion and the subsequent recommendations for a pV-value and the adequate phrases for explanation are introduced.