Preparation of two synthetic isotope mixtures for the calibration of isotope amount ratio measurements of sulfur

  • Two synthetic isotope mixtures for the calibration of sulfur isotope amount ratio measurements were gravimetrically prepared from high purity Ag2S materials enriched in 32S, 33S, and 34S. The mixtures were made so as to closely resemble the (natural) isotopic composition of the materials to be “calibrated”. This allowed a totally independent evaluation, on the same samples, of the relative combined uncertainty of: (a) the procedure to perform direct measurements of the amount of substance ratios of gas isotopes in the redetermination of the Avogadro constant and (b) the gravimetric preparation procedure. The result of both procedures, mass spectrometry and gravimetry, agree to a relative uncertainty of 3 × 10-4 for sulfur amount ratio measurements of the major abundant isotopes. Thus it seems that a direct measurement of isotopic gas mixtures (e.g. of natural isotopic composition) is now possible for sulfur—and probably also for other gaseous isotopes—without necessarily having to relyTwo synthetic isotope mixtures for the calibration of sulfur isotope amount ratio measurements were gravimetrically prepared from high purity Ag2S materials enriched in 32S, 33S, and 34S. The mixtures were made so as to closely resemble the (natural) isotopic composition of the materials to be “calibrated”. This allowed a totally independent evaluation, on the same samples, of the relative combined uncertainty of: (a) the procedure to perform direct measurements of the amount of substance ratios of gas isotopes in the redetermination of the Avogadro constant and (b) the gravimetric preparation procedure. The result of both procedures, mass spectrometry and gravimetry, agree to a relative uncertainty of 3 × 10-4 for sulfur amount ratio measurements of the major abundant isotopes. Thus it seems that a direct measurement of isotopic gas mixtures (e.g. of natural isotopic composition) is now possible for sulfur—and probably also for other gaseous isotopes—without necessarily having to rely on “calibration” by means of values provided by measurements of gravimetrically prepared isotope mixtures. However, synthetic mixtures may be needed for validation and verification purposes, in particular for quality assurance.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Heinrich Kipphardt, T. Ding, S. Valkiers, C. Quetel, P. De Bièvre, P. Taylor, R. Gonfiantini
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):International Journal of Mass Spectrometry
Jahr der Erstveröffentlichung:2000
Verlag:Elsevier
Verlagsort:Amsterdam
Jahrgang/Band:197
Ausgabe/Heft:1-3
Erste Seite:131
Letzte Seite:137
Freie Schlagwörter:Absolute isotope amount ratio; Mass spectrometry; Sulfur; Sulfur hexafluoride; Synthetic isotope mixtures
DOI:10.1016/S1387-3806(99)00235-3
ISSN:0168-1176
ISSN:0020-7381
ISSN:1387-3806
ISSN:1873-2798
Verfügbarkeit des Dokuments:Weder Datei noch physisches Exemplar vorhanden ("No Access")
Datum der Freischaltung:19.02.2016
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:12.09.2000
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.