A practicable nominal temperature tolerance for TMF-tests

  • The aim of this research was to investigate the influence of nominal temperature errors on test results and to develop the nominal temperature tolerance for TMF-tests. This concept was confirmed with series of specially developed TMF-tests with defined temperature errors, performed on one test material (NIMONIC 90) in a temperature range of 400–850 °C. These tests should show the influence of temperature errors on test results with an emphasis on lifetime in comparison with reference tests. It is shown that with a limited number of specimens and only one test material, it is possible to propose a reasonable general temperature tolerance for TMF-tests, valid for a wide range of materials and test conditions.

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Hans-Joachim Kühn, Ole Kahlcke, Stephen-Peter Brookes
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):International Journal of Fatigue
Jahr der Erstveröffentlichung:2008
Verlag:Elsevier
Verlagsort:Oxford
Jahrgang/Band:30
Ausgabe/Heft:2
Erste Seite:277
Letzte Seite:285
Freie Schlagwörter:Life time; Temperature error; Temperature tolerance; Thermo-mechanical fatigue
DOI:10.1016/j.ijfatigue.2007.01.057
ISSN:0142-1123
Verfügbarkeit des Dokuments:Physisches Exemplar in der Bibliothek der BAM vorhanden ("Hardcopy Access")
Bibliotheksstandort:Sonderstandort: Publica-Schrank
Datum der Freischaltung:19.02.2016
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:12.11.2007
Einverstanden