A practicable nominal temperature tolerance for TMF-tests
- The aim of this research was to investigate the influence of nominal temperature errors on test results and to develop the nominal temperature tolerance for TMF-tests. This concept was confirmed with series of specially developed TMF-tests with defined temperature errors, performed on one test material (NIMONIC 90) in a temperature range of 400850 °C. These tests should show the influence of temperature errors on test results with an emphasis on lifetime in comparison with reference tests. It is shown that with a limited number of specimens and only one test material, it is possible to propose a reasonable general temperature tolerance for TMF-tests, valid for a wide range of materials and test conditions.
Autor*innen: | Hans-Joachim Kühn, Ole Kahlcke, Stephen-Peter Brookes |
---|---|
Dokumenttyp: | Zeitschriftenartikel |
Veröffentlichungsform: | Verlagsliteratur |
Sprache: | Englisch |
Titel des übergeordneten Werkes (Englisch): | International Journal of Fatigue |
Jahr der Erstveröffentlichung: | 2008 |
Verlag: | Elsevier |
Verlagsort: | Oxford |
Jahrgang/Band: | 30 |
Ausgabe/Heft: | 2 |
Erste Seite: | 277 |
Letzte Seite: | 285 |
Freie Schlagwörter: | Life time; Temperature error; Temperature tolerance; Thermo-mechanical fatigue |
DOI: | 10.1016/j.ijfatigue.2007.01.057 |
ISSN: | 0142-1123 |
Verfügbarkeit des Dokuments: | Physisches Exemplar in der Bibliothek der BAM vorhanden ("Hardcopy Access") |
Bibliotheksstandort: | Sonderstandort: Publica-Schrank |
Datum der Freischaltung: | 19.02.2016 |
Referierte Publikation: | Ja |
Datum der Eintragung als referierte Publikation: | 12.11.2007 |