• Treffer 3 von 15
Zurück zur Trefferliste

A comparison of chromatographic methods for the determination of deoxynivalenol in wheat

  • Liquid chromatography coupled with tandem mass spectrometric detection has gained more importance for mycotoxin determination in recent years. In addition to instrumental improvements, the development of LC-MS-MS has also been a consequence of the availability of stable isotope internal standards, e.g., 13C-labelled mycotoxins. Thus, the LC-ESI-MS-MS method using a 13C15-deoxynivalenol internal standard as a state-of-the-art technique was selected as a reference procedure for an in-house method comparison study of the determination of deoxynivalenol (DON) in wheat materials. Alternative methods include LC-diode array detection, which is a frequently used routine procedure for DON-analysis, and gas chromatography after trimethylsilylation. For GC application, an electron capture detector and a negative chemical ionisation mass spectrometry detector were used, which have both been well described in the literature. The method comparison was conducted using t test statistics. Additionally,Liquid chromatography coupled with tandem mass spectrometric detection has gained more importance for mycotoxin determination in recent years. In addition to instrumental improvements, the development of LC-MS-MS has also been a consequence of the availability of stable isotope internal standards, e.g., 13C-labelled mycotoxins. Thus, the LC-ESI-MS-MS method using a 13C15-deoxynivalenol internal standard as a state-of-the-art technique was selected as a reference procedure for an in-house method comparison study of the determination of deoxynivalenol (DON) in wheat materials. Alternative methods include LC-diode array detection, which is a frequently used routine procedure for DON-analysis, and gas chromatography after trimethylsilylation. For GC application, an electron capture detector and a negative chemical ionisation mass spectrometry detector were used, which have both been well described in the literature. The method comparison was conducted using t test statistics. Additionally, this study also calculates important method performance characteristics, including accuracy, linearity, limit of detection, limit of quantification, recovery, and variation coefficient. Furthermore, this is the first report of a GC-MS method for the determination of DON using a fully carbon-labelled 13C15-DON as an IS. The GC-MS using 13C15-DON as an IS has produced comparable results to the 13C-IS-LC-MS-MS reference method with a similar sensitivity. ECD detection was slightly less sensitive, but is also suited for DON analysis in wheat. Due to the high LOQ, the LC-DAD method seems highly applicable to the measurement of highly contaminated samples.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Torsten Neuhof, Natalie Ganzauer, Matthias KochORCiD, Irene Nehls
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Chromatographia
Jahr der Erstveröffentlichung:2009
Verlag:Vieweg
Verlagsort:Wiesbaden
Jahrgang/Band:69
Ausgabe/Heft:11-12
Erste Seite:1457
Letzte Seite:1462
Freie Schlagwörter:Column liquid chromatography-mass spectrometry; Gas chromatography; Mycotoxins; Trichothecenes
DOI:10.1365/s10337-009-1084-1
ISSN:0009-5893
ISSN:1612-1112
Verfügbarkeit des Dokuments:Physisches Exemplar in der Bibliothek der BAM vorhanden ("Hardcopy Access")
Bibliotheksstandort:Sonderstandort: Publica-Schrank
Datum der Freischaltung:19.02.2016
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:09.07.2009
Einverstanden