• Treffer 3 von 96
Zurück zur Trefferliste

The scanning force microscope as a tool for the detection of local mechanical properties within the interphase of fibre reinforced polymers

  • Scanning force microscopy (SFM) has been used to assess the local mechanical properties of fibre-reinforced polymers. Using a sinusoidal displacement modulation (DM) and lock-in technique the method allows to characterize local viscoelastic properties with a high lateral resolution. The simultaneous measurement of the local electrical conductivity is proposed which facilitates the interpretation of the mechanical data. The investigation of cross-sections perpendicular to the axis of carbon fibres embedded in PPS delivers some information about the change in local stiffness within the interfacial region. As a first approach, assuming a single-exponential decrease in local stiffness along a radial line from fibre to polymer we find characteristic decay lengths which are distributed in a range between 20 and 80nm. Further, a modified DM-mode is proposed which is expected to provide a contrast enhancement of the signal which is related to local stiffness. This can be achieved by installingScanning force microscopy (SFM) has been used to assess the local mechanical properties of fibre-reinforced polymers. Using a sinusoidal displacement modulation (DM) and lock-in technique the method allows to characterize local viscoelastic properties with a high lateral resolution. The simultaneous measurement of the local electrical conductivity is proposed which facilitates the interpretation of the mechanical data. The investigation of cross-sections perpendicular to the axis of carbon fibres embedded in PPS delivers some information about the change in local stiffness within the interfacial region. As a first approach, assuming a single-exponential decrease in local stiffness along a radial line from fibre to polymer we find characteristic decay lengths which are distributed in a range between 20 and 80nm. Further, a modified DM-mode is proposed which is expected to provide a contrast enhancement of the signal which is related to local stiffness. This can be achieved by installing an additional feedback loop which keeps constant the amplitude of dynamic indentation (CDI-mode).zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Martin Munz, Heinz SturmORCiD, Eckhard Schulz, G. Hinrichsen
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Composites / A
Jahr der Erstveröffentlichung:1998
Verlag:Elsevier
Verlagsort:Oxford
Jahrgang/Band:29
Erste Seite:1251
Letzte Seite:1259
Freie Schlagwörter:Interface/interphase; Nondestructive testing; Polymer-matrix composites (PMC´s); SFM/AFM; Surface properties
DOI:10.1016/S1359-835X(98)00077-3
ISSN:1359-835X
Verfügbarkeit des Dokuments:Weder Datei noch physisches Exemplar vorhanden ("No Access")
Datum der Freischaltung:19.02.2016
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:21.02.2002
Einverstanden