Modified paramagnetic beads in a microfluidic system for the determination of ethinylestradiol (EE2) in river water samples

  • In this work, we have developed and characterized a novel microfluidic immunoassay methodology for rapid and sensitive quantification of ethinylestradiol (EE2) in river water samples. The detection of EE2 was carried out using a competitive direct immunoassay method based on the use of anti-EE2 polyclonal antibodies immobilized on magnetic microspheres 3-aminopropyl-modified manipulated for an external removable magnet. The EE2 present in the water sample was allowed to compete with EE2-horseradish peroxidase (HPR) conjugated for the immobilized anti-EE2 antibody. The HPR, in the presence of hydrogen peroxide (H2O2) catalyzes the oxidation of catechol (Q) whose back electrochemical reduction was detected on gold electrode at 0.0 V. The response current obtained from the product of enzymatic reaction is inversely proportional to the amount of EE2 in the water sample. The electrochemical detection can be done within 1 min and total assay time was 30 min. The calculated detection limitsIn this work, we have developed and characterized a novel microfluidic immunoassay methodology for rapid and sensitive quantification of ethinylestradiol (EE2) in river water samples. The detection of EE2 was carried out using a competitive direct immunoassay method based on the use of anti-EE2 polyclonal antibodies immobilized on magnetic microspheres 3-aminopropyl-modified manipulated for an external removable magnet. The EE2 present in the water sample was allowed to compete with EE2-horseradish peroxidase (HPR) conjugated for the immobilized anti-EE2 antibody. The HPR, in the presence of hydrogen peroxide (H2O2) catalyzes the oxidation of catechol (Q) whose back electrochemical reduction was detected on gold electrode at 0.0 V. The response current obtained from the product of enzymatic reaction is inversely proportional to the amount of EE2 in the water sample. The electrochemical detection can be done within 1 min and total assay time was 30 min. The calculated detection limits for electrochemical detection and the ELISA procedure are 0.09 and 0.32 ng L-1 respectively and the intra- and inter-assay coefficients of variation were below 5.8%. Our electrochemical immunosensor showed higher sensitivity and lower time consumed than the standard spectrophotometric detection ELISA method, which shows the potential for assessment of EE2 in river water samples.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:N.A. Martínez, Rudolf SchneiderORCiD, G.A. Messina, J. Raba
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Biosensors & bioelectronics
Jahr der Erstveröffentlichung:2010
Verlag:Elsevier
Verlagsort:Barking, Essex, UK
Jahrgang/Band:25
Ausgabe/Heft:6
Erste Seite:1376
Letzte Seite:1381
Freie Schlagwörter:Enzyme immunoassays; Ethinylestradiol; Flow injection analysis; Horseradish peroxidase; Microfluidic; Paramagnetic beads
DOI:10.1016/j.bios.2009.10.031
ISSN:0956-5663
ISSN:1873-4235
Verfügbarkeit des Dokuments:Physisches Exemplar in der Bibliothek der BAM vorhanden ("Hardcopy Access")
Bibliotheksstandort:Sonderstandort: Publica-Schrank
Datum der Freischaltung:19.02.2016
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:28.10.2010
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.