Mobile 3D-X-Ray Tomography for Analysis of Planar Defects in Welds by "Tomocar"

  • Tomographical Computer Aided Radiology (TomoCAR) is based on the mechanical position control of an X-ray tube in front of a welding seam and the application of a planar array detector behind it. Several hundred radiometric projections in small angle steps are acquired. The tomographical reconstruction allows the three-dimensional (3D) representation of the defects. A new radiometric array detector system with a small internal unsharpness and high image contrast is used for the 2- and 3-dimensional visualization and sizing of planar defects with a defect opening of less than 100 µm. This detector is based on a CMOS-flat panel with a direct converting CdTe-single crystal layer. The small design allows the application of the mobile testing equipment for mechanized X-ray inspection in industrial plants. The physical pixel size of the detector amounts to 0,1x0,1 mm². Nevertheless, this system yields a better spatial resolution than indirect converting detectors (e.g. cameras withTomographical Computer Aided Radiology (TomoCAR) is based on the mechanical position control of an X-ray tube in front of a welding seam and the application of a planar array detector behind it. Several hundred radiometric projections in small angle steps are acquired. The tomographical reconstruction allows the three-dimensional (3D) representation of the defects. A new radiometric array detector system with a small internal unsharpness and high image contrast is used for the 2- and 3-dimensional visualization and sizing of planar defects with a defect opening of less than 100 µm. This detector is based on a CMOS-flat panel with a direct converting CdTe-single crystal layer. The small design allows the application of the mobile testing equipment for mechanized X-ray inspection in industrial plants. The physical pixel size of the detector amounts to 0,1x0,1 mm². Nevertheless, this system yields a better spatial resolution than indirect converting detectors (e.g. cameras with fluorescence layers of Gd2O2S). It allows the reliable detection of planar defects with openings far below the detector pixel size by subpixel resolution. 'TomoCAR' is qualified at present in the context with a German pilot study following to the ENIQ guidelines for the employment within the nuclear power industry.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Bernhard Redmer, Uwe Ewert, Christoph Rädel, Uwe ZscherpelORCiD, A.V. Likhatchov, V.V. Pickalov, B. Neundorf
Dokumenttyp:Beitrag zu einem Sammelband
Veröffentlichungsform:Graue Literatur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):16th World Conference on Nondestructive Testing
Jahr der Erstveröffentlichung:2004
Herausgeber (Institution):Canadian Institute for NDE
Verlag:International Committee for Non-Destructive Testing
Verlagsort:Montreal
Erste Seite:8 pages
Freie Schlagwörter:Digitale Radiologie; Laminografie; Mobile Anwendungen; Radiometrie
Veranstaltung:16th World Conference on Nondestructive Testing
Veranstaltungsort:Montreal, Canada
Beginndatum der Veranstaltung:2004-08-30
Enddatum der Veranstaltung:2004-09-03