• Treffer 18 von 18
Zurück zur Trefferliste

Inhibition of Mineralization by a Calcium Zirconium Phosphate Coating

  • Bioactive ceramics used as coating materials combine the conductive properties of a bioceramic with the mechanical stability of the metal implant. We studied a calcium zirconium phosphate-containing coating material, FA-CZP [Ca5(PO4)3F, CaZr4(PO4)6], that is relatively insoluble in the biological milieu. The reaction of bone to this material was investigated histologically and histomorphometrically in an animal trial. Cylindrical Ti6Al4V specimens that had been coated with FA-CZP by plasma spraying were implanted in the femoral condyles of rabbits. The implants were left in place for 2, 4, 6, 12, and 14 weeks. FA-CZP led to impaired mineralization of the newly formed bone at the interface. Noncalcified osteoid was found throughout the whole study period. The layer seemed to become thicker with time. The mineralization disorder is evidently caused by zirconium ions. The presence of zirconium in the osteoid in contact with the implant was demonstrated by means of two different stainingBioactive ceramics used as coating materials combine the conductive properties of a bioceramic with the mechanical stability of the metal implant. We studied a calcium zirconium phosphate-containing coating material, FA-CZP [Ca5(PO4)3F, CaZr4(PO4)6], that is relatively insoluble in the biological milieu. The reaction of bone to this material was investigated histologically and histomorphometrically in an animal trial. Cylindrical Ti6Al4V specimens that had been coated with FA-CZP by plasma spraying were implanted in the femoral condyles of rabbits. The implants were left in place for 2, 4, 6, 12, and 14 weeks. FA-CZP led to impaired mineralization of the newly formed bone at the interface. Noncalcified osteoid was found throughout the whole study period. The layer seemed to become thicker with time. The mineralization disorder is evidently caused by zirconium ions. The presence of zirconium in the osteoid in contact with the implant was demonstrated by means of two different staining methods.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:A. Bernstein, D. Nöbel, H.O. Mayr, F. Göbel, Georg Berger, Ute Ploska, Renate Gildenhaar, J. Brandt
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Journal of biomedical materials research / B
Jahr der Erstveröffentlichung:2008
Herausgeber (Institution):Society for Biomaterials
Verlag:Wiley
Verlagsort:Hoboken, NJ
Jahrgang/Band:86B
Ausgabe/Heft:2
Erste Seite:422
Letzte Seite:429
Freie Schlagwörter:Bone; Ceramic; Coating(s); Mineralization; Toxicity
DOI:10.1002/jbm.b.31037
ISSN:1552-4973
ISSN:1552-4981
Verfügbarkeit des Dokuments:Physisches Exemplar in der Bibliothek der BAM vorhanden ("Hardcopy Access")
Bibliotheksstandort:Sonderstandort: Publica-Schrank
Datum der Freischaltung:19.02.2016
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:04.09.2008
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.