Development of fire-retarded materials-Interpretation of cone calorimeter data

  • There is little consensus within the fire science community on interpretation of cone calorimeter data, but there is a significant need to screen new flammability modified materials using the cone calorimeter. This article is the result of several discussions aiming to provide guidance in the use and interpretation of cone calorimetry for those directly involved with such measurements. This guidance is essentially empirical, and is not intended to replace the comprehensive scientific studies that already exist. The guidance discusses the fire scenario with respect to applied heat flux, length scale, temperature, ventilation, anaerobic pyrolysis and set-up represented by the cone calorimeter. The fire properties measured in the cone calorimeter are discussed, including heat release rate and its peak, the mass loss and char yield, effective heat of combustion and combustion efficiency, time to ignition and CO and smoke production together with deduced quantities such as FIGRA and MARHE.There is little consensus within the fire science community on interpretation of cone calorimeter data, but there is a significant need to screen new flammability modified materials using the cone calorimeter. This article is the result of several discussions aiming to provide guidance in the use and interpretation of cone calorimetry for those directly involved with such measurements. This guidance is essentially empirical, and is not intended to replace the comprehensive scientific studies that already exist. The guidance discusses the fire scenario with respect to applied heat flux, length scale, temperature, ventilation, anaerobic pyrolysis and set-up represented by the cone calorimeter. The fire properties measured in the cone calorimeter are discussed, including heat release rate and its peak, the mass loss and char yield, effective heat of combustion and combustion efficiency, time to ignition and CO and smoke production together with deduced quantities such as FIGRA and MARHE. Special comments are made on the use of the cone calorimeter relating to sample thickness, textiles, foams and intumescent materials, and the distance of the cone heater from the sample surface. Finally, the relationship between cone calorimetry data and other tests is discussed.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Bernhard SchartelORCiD, T.R. Hull
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Fire and materials
Jahr der Erstveröffentlichung:2007
Verlag:Heyden
Verlagsort:London
Jahrgang/Band:31
Ausgabe/Heft:5
Erste Seite:327
Letzte Seite:354
Freie Schlagwörter:Cone calorimetry; Fire retardant; Heat release
ISSN:0308-0501
ISSN:1099-1018
Verfügbarkeit des Dokuments:Physisches Exemplar in der Bibliothek der BAM vorhanden ("Hardcopy Access")
Bibliotheksstandort:Sonderstandort: Publica-Schrank
Datum der Freischaltung:19.02.2016
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:19.07.2007