Produktion und Systeme
Refine
Year of publication
- 2003 (16) (remove)
Document Type
Has Fulltext
- no (16)
Is part of the Bibliography
- no (16)
Keywords
- Garnet films (2)
- Imaging (2)
- Magnetic flux leakage (2)
- Magneto-optics (2)
- Coercive Force (1)
- Defects (1)
- Field Dependence (1)
- Flux leakage (1)
- Magnetic Permeability (1)
- Magnetic methods (1)
Institute
- Fakultät Elektro- und Informationstechnik (16) (remove)
Begutachtungsstatus
- peer-reviewed (5)
Various theoretical models (self-consistent field, local linearization, and percolation theory methods and an analytic solution of the linear problem for an ordered medium) for calculating the magnetostatic properties of two-phase composites containing one ferromagnetic phase were considered. The concentration and field dependences of the effective magnetic permeability were found. A method for determining the coercive force and remanent magnetization as functions of the ferromagnetic phase concentration was suggested. Numerical experiments were performed for composites with a periodic distribution of circular inclusions. The results were compared with the analytically calculated effective magnetic permeability.
Illumination of ac-biased photorefractive Bi12TiO20 crystals with a coherent light beam results in the development of strong nonlinear scattering. Theoretically and experimentally we investigate the angular and polarization characteristics of the scattered light for the diagonal ([1̲1̲1]) optical configuration and different polarization states of the pump. A satisfactory understanding of the observed scattering properties is achieved for most of the cases investigated.
Rare-earth iron garnet films with in-plane anisotropy grown on (111)-oriented substrates can be used as magneto-optical indicator films for visualization of magnetic leakage fields in nondestructive evaluation. The influence of Faraday rotation, Faraday ellipticity, absorption and film thickness on the performance of a magneto-optical indicator film is investigated. A new optimization method is introduced and compared with the method of contrast optimization. The theory is experimentally verified and an application example is presented.
A novel analytical approach for calculating the magnetic leakage field from surface defects is proposed and demonstrated for the case of a linear ferromagnetic material. The novelty of the theory is that it relates the distribution of induced magnetic charges to the surface shape. An excellent agreement between the analytical and numerical results is shown. The functional relations between different magnetic field components are discussed.
Rare-earth iron garnet films with in-plane anisotropy grown on (111)-oriented substrates can be used as magneto-optical indicator films for visualization of magnetic leakage fields in nondestructive evaluation. The influence of Faraday rotation, Faraday ellipticity, absorption and film thickness on the performance of a magneto-optical indicator film is investigated. A new optimization method is introduced and compared with the method of contrast optimization. The theory is experimentally verified and an application example is presented.
Mechanical properties of biological tissue represent important diagnostic information and are of histological relevance (hard lesions, "nodes" in organs: tumors; calcifications in vessels: arteriosclerosis). The problem is, that such information is usually obtained by digital palpation only, which is limited with respect to sensitivity. It requires intuitive assessment and does not allow quantitative documentation. A suitable sensor is required for quantitative detection of mechanical tissue properties. On the other hand, there is also some need for a realistic mechanical display of those tissue properties. Suitable actuator arrays with high spatial resolution and real-time capabilities are required operating in a haptic sensor actuator system with different applications. The sensor system uses real time ultrasonic elastography whereas the tactile actuator is based on electrorheological fluids. Due to their small size the actuator array elements have to be manufactured by micro-mechanical production methods. In order to supply the actuator elements with individual high voltages a sophisticated switching and control concept have been designed. This haptic system has the potential of inducing real time substantial forces, using a compact lightweight mechanism which can be applied to numerous areas including intraoperative navigation, telemedicine, teaching, space and telecommunication.
The ability to image the elastic properties of tissue is potentially useful in a variety of applications. The field of elastic imaging has grown in response to the Potential use of such information in medical diagnosis. Real time ultrasound elastography represents a recent development in determining strain and elasticity distributions. Nevertheless, commonly used imaging techniques rely on the interpretation of two dimensional visual data displayed on a video screen. In reality however, physicians often prefer tactile exploration making the simultaneous portrayal of both video and haptic information most desirable.
Since the 1970's many alphanumeric to tactile data conversion methods have been investigated, mainly with the ultimate aim of assisting the blind. More recently, interest has been directed toward the display of pictures on haptically explorable surfaces - Tactile imaging. Such a system would allow surgeons to examine hard sectors contained within soft tissue, and thereby assist in operations held remotely. The expansion of ultrasound elastography to 3D formats would mean the ability to haptically explore regions of the body normally inaccessible to human hands. For three-dimensional imaging the acquisition of sequential tomographic slices using Elastography, combined with image segmentation, enables the reconstruction, quantification and visualisation of tumour volumes.
In a collaborative project between four research Institutes, the aim is to produce a prototype three dimensional tactile displays comprising electrically switchable micromachined cells, whose mechanical moduli are governed by phase changes experienced by electrorheological and/or magnetorheological fluids. This will be integrated with a sensory ultrasonic elastography in order to present the human fingers with controllable surfaces capable of emulating biological tissue, muscle and bone.
Since the 1960s many alphanumeric to tactile data conversion methods have been investigated, mainly with the ultimate aim of assisting the blind. More recently, interest has been directed toward the display of pictures on haptically explorable surfaces – tactile imaging – for a range of medical, remote sensing and entertainment purposes. This paper examines the technologies which have been utilised for haptically explorable tactile displays over the past three decades, focussing on those which appear commercially viable in the immediate future.