Refine
Year of publication
Document Type
Is part of the Bibliography
- no (38)
Keywords
- Lernprogramm (7)
- Handchirurgie (6)
- Deep Learning (5)
- Maschinelles Lernen (5)
- Osteosynthese (5)
- Bildgebendes Verfahren (4)
- Bildverarbeitung (4)
- Diagnose (4)
- Medizin (4)
- Speiseröhrenkrankheit (4)
Institute
- Regensburg Center of Biomedical Engineering - RCBE (38) (remove)
Begutachtungsstatus
- peer-reviewed (25)
The German workshop on medical image computing (BVM) has been held in different locations in Germany for more than 20 years. In terms of content, BVM focused on the computer-aided analysis of medical image data with a wide range of applications, e.g. in the area of imaging, diagnostics, operation planning, computer-aided intervention and visualization.
During this time, there have been remarkable methodological developments and upheavals, on which the BVM community has worked intensively. The area of machine learning should be emphasized, which has led to significant improvements, especially for tasks of classification and segmentation, but increasingly also in image formation and registration. As a result, work in connection with deep learning now dominates the BVM. These developments have also contributed to the establishment of medical image processing at the interface between computer science and medicine as one of the key technologies for the digitization of the health system.
In addition to the presentation of current research results, a central aspect of the BVM is primarily the promotion of young scientists from the diverse BVM community, covering not only Germany but also Austria, Switzerland, The Netherland and other European neighbors. The conference serves primarily doctoral students and postdocs, but also students with excellent bachelor and master theses as a platform to present their work, to enter into professional discourse with the community, and to establish networks with specialist colleagues. Despite the many conferences and congresses that are also relevant for medical image processing, the BVM has therefore lost none of its importance and attractiveness and has retained its permanent place in the annual conference rhythm.
Building on this foundation, there are some innovations and changes this year. The BVM 2021 was organized for the first time at the Ostbayerische Technische Hochschule Regensburg (OTH Regensburg, a technical university of applied sciences). After Aachen, Berlin, Erlangen, Freiburg, Hamburg, Heidelberg, Leipzig, Lübeck, and Munich, Regensburg is not just a new venue. OTH Regensburg is the first representative of the universities of applied sciences (HAW) to organize the conference, which differs to universities, university hospitals, or research centers like Fraunhofer or Helmholtz. This also considers the further development of the research landscape in Germany, where HAWs increasingly contribute to applied research in addition to their focus on teaching. This development is also reflected in the contributions submitted to the BVM in recent years.
At BVM 2021, which was held in a virtual format for the first time due to the Corona pandemic, an attractive and high-quality program was offered. Fortunately, the number of submissions increased significantly. Out of 97 submissions, 26 presentations, 51 posters and 5 software demonstrations were accepted via an anonymized reviewing process with three reviews each. The three best works have been awarded BVM prizes, selected by a separate committee.
Based on these high-quality submissions, we are able to present another special issue in the International Journal of Computer Assisted Radiology and Surgery (IJCARS). Out of the 97 submissions, the ones with the highest scores have been invited to submit an extended version of their paper to be presented in IJCARS. As a result, we are now able to present this special issue with seven excellent articles. Many submissions focus on machine learning in a medical context.
Background: Currently, it is common practice to use three-dimensional (3D) printers not only for rapid prototyping in the industry, but also in the medical area to create medical applications for training inexperienced surgeons. In a clinical training simulator for minimally invasive bone drilling to fix hand fractures with Kirschner-wires (K-wires), a 3D-printed hand phantom must not only be geometrically but also haptically correct. Due to a limited view during an operation, surgeons need to perfectly localize underlying risk structures only by feeling of specific bony protrusions of the human hand.
Methods: The goal of this experiment is to imitate human soft tissue with its haptic and elasticity for a realistic hand phantom fabrication, using only a dual-material 3D printer and support-material-filled metamaterial between skin and bone. We present our workflow to generate lattice structures between hard bone and soft skin with iterative cube edge (CE) or cube face (CF) unit cells. Cuboid and finger shaped sample prints with and without inner hard bone in different lattice thickness are constructed and 3D printed.
Results: The most elastic available rubber-like material is too firm to imitate soft tissue. By reducing the amount of rubber in the inner volume through support material (SUP), objects become significantly softer. Without metamaterial, after disintegration, the SUP can be shifted through the volume and thus the body loses its original shape. Although the CE design increases the elasticity, it cannot restore the fabric form. In contrast to CE, the CF design increases not only the elasticity but also guarantees a local limitation of the SUP. Therefore, the body retains its shape and internal bones remain in its intended place. Various unit cell sizes, lattice thickening and skin thickness regulate the rubber material and SUP ratio. Test prints with higher SUP and lower rubber material percentage appear softer and vice versa. This was confirmed by an expert surgeon evaluation. Subjects adjudged pure rubber-like material as too firm and samples only filled with SUP or lattice structure in CE design as not suitable for imitating tissue. 3D-printed finger samples in CF design were rated as realistic compared to the haptic of human tissue with a good palpable bone structure.
Conclusions: We developed a new dual-material 3D print technique to imitate soft tissue of the human hand with its haptic properties. Blowy SUP is trapped within a lattice structure to soften rubber-like 3D print material, which makes it possible to reproduce a realistic replica of human hand soft tissue.
Vascular malformations (VMs) are a rare condition. They can be categorized into high-flow and low-flow VMs, which is a challenging task for radiologists. In this work, a very heterogeneous set of MRI images with only rough annotations are used for classification with a convolutional neural network. The main focus is to describe the challenging data set and strategies to deal with such data in terms of preprocessing, annotation usage and choice of the network architecture. We achieved a classification result of 89.47 % F1-score with a 3D ResNet 18.
Currently, it is common practice to use three-dimensional (3D) printers not only for rapid prototyping in the industry, but also in the medical area to create medical applications for training inexperienced surgeons. In a clinical training simulator for minimally invasive bone drilling to fix hand fractures with Kirschner-wires (K-wires), a 3D printed hand phantom must not only be geometrically but also haptically correct. Due to a limited view during an operation, surgeons need to perfectly localize underlying risk structures only by feeling of specific bony protrusions of the human hand.
Die Implantation eines Cochlea Implantates benötigt einen chirurgischen Zugang im Felsenbein und durch die Paukenhöhle des Patienten. Der Chirurg hat eine eingeschränkte Sicht im Operationsgebiet, die weiterhin viele Risikostrukturen enthält. Um eine Cochlea Implantation sicher und fehlerfrei durchzuführen, ist eine umfangreiche theoretische und praktische (teilweise berufsbegleitende) Fortbildung sowie langjährige Erfahrung notwendig. Unter Nutzung von realen klinischen CT/MRT Daten von Innen- und Mittelohr und der interaktiven Segmentierung der darin abgebildeten Strukturen (Nerven, Cochlea, Gehörknöchelchen,...) wird im HaptiVisT Projekt ein haptisch-visuelles Trainingssystem für die Implantation von Innen- und Mittelohr-Implantaten realisiert, das als sog. „Serious Game“ mit immersiver Didaktik gestaltet wird. Die Evaluierung des Demonstrators hinsichtlich Zweckmäßigkeit erfolgt prozessbegleitend und ergebnisorientiert, um mögliche technische oder didaktische Fehler vor Fertigstellung des Systems aufzudecken. Drei zeitlich versetzte Evaluationen fokussieren dabei chirurgisch-fachliche, didaktische sowie haptisch-ergonomische Akzeptanzkriterien.
Background
Breast reconstruction is an important coping tool for patients undergoing a mastectomy. There are numerous surgical techniques in breast reconstruction surgery (BRS). Regardless of the technique used, creating a symmetric outcome is crucial for patients and plastic surgeons. Three-dimensional surface imaging enables surgeons and patients to assess the outcome’s symmetry in BRS. To discriminate between autologous and alloplastic techniques, we analyzed both techniques using objective optical computerized symmetry analysis. Software was developed that enables clinicians to assess optical breast symmetry using three-dimensional surface imaging.
Methods
Twenty-seven patients who had undergone autologous (n = 12) or alloplastic (n = 15) BRS received three-dimensional surface imaging. Anthropomorphic data were collected digitally using semiautomatic measurements and automatic measurements. Automatic measurements were taken using the newly developed software. To quantify symmetry, a Symmetry Index is proposed.
Results
Statistical analysis revealed that there is no dif- ference in the outcome symmetry between the two groups (t test for independent samples; p = 0.48, two-tailed).
Conclusion
This study’s findings provide a foundation for qualitative symmetry assessment in BRS using automatized digital anthropometry. In the present trial, no difference in the outcomes’ optical symmetry was detected between autologous and alloplastic approaches.
Structural MRI brain analysis and segmentation is a crucial part in the daily routine in neurosurgery for intervention planning. Exemplarily, the free software FSL-FAST (FMRIB’s Segmentation Library – FMRIB’s Automated Segmentation Tool) in version 4 is used for segmentation of brain tissue types. To speed up the segmentation procedure by parallel execution, we transferred FSL-FAST to a General Purpose Graphics Processing Unit (GPGPU) using Open Computing Language (OpenCL) [1]. The necessary steps for parallelization resulted in substantially different and less useful results. Therefore, the underlying methods were revised and adapted yielding computational overhead. Nevertheless, we achieved a speed-up factor of 3.59 from CPU to GPGPU execution, as well providing similar useful or even better results.
One common method to fix fractures of the human hand after an accident is an osteosynthesis with Kirschner wires (K-wires) to stabilize the bone fragments. The insertion of K-wires is a delicate minimally invasive surgery, because surgeons operate almost without a sight. Since realistic training methods are time consuming, costly and insufficient, a virtual-reality (VR) based training system for the placement of K-wires was developed. As part of this, the current work deals with the real-time bone drilling simulation using a haptic force-feedback device.
To simulate the drilling, we introduce a virtual fixture based force-feedback drilling approach. By decomposition of the drilling task into individual phases, each phase can be handled individually to perfectly control the drilling procedure. We report about the related finite state machine (FSM), describe the haptic feedback of each state and explain, how to avoid jerking of the haptic force-feedback during state transition.
The usage of the virtual fixture approach results in a good haptic performance and a stable drilling behavior. This was confirmed by 26 expert surgeons, who evaluated the virtual drilling on the simulator and rated it as very realistic. To make the system even more convincing, we determined real drilling feed rates through experimental pig bone drilling and transferred them to our system. Due to a constant simulation thread we can guarantee a precise drilling motion.
Virtual fixtures based force-feedback calculation is able to simulate force-feedback assisted bone drilling with high quality and, thus, will have a great potential in developing medical applications.
Computer-assisted analysis of endoscopic images can be helpful to the automatic diagnosis and classification of neoplastic lesions. Barrett's esophagus (BE) is a common type of reflux that is not straight forward to be detected by endoscopic surveillance, thus being way susceptible to erroneous diagnosis, which can cause cancer when not treated properly. In this work, we introduce the Optimum-Path Forest (OPF) classifier to the task of automatic identification of Barrett'sesophagus, with promising results and outperforming the well known Support Vector Machines (SVM) in the aforementioned context. We consider describing endoscopic images by means of feature extractors based on key point information, such as the Speeded up Robust Features (SURF) and Scale-Invariant Feature Transform (SIFT), for further designing a bag-of-visual-wordsthat is used to feed both OPF and SVM classifiers. The best results were obtained by means of the OPF classifier for both feature extractors, with values lying on 0.732 (SURF) - 0.735(SIFT) for sensitivity, 0.782 (SURF) - 0.806 (SIFT) for specificity, and 0.738 (SURF) - 0.732 (SIFT) for the accuracy.
Introduction – Diagnosis of abnormal cilia function is based on ultrastructural analysis of axoneme defects, especialy the features of inner and outer dynein arms which are the motors of ciliar motility. Sub-optimal biopsy material, methodical, and intrinsic electron microscopy factors pose difficulty in ciliary defects evaluation. We present a computer-assisted approach based on state-of-the-art image analysis and object recognition methods yielding a time-saving and efficient diagnosis of cilia dysfunction. Method – The presented approach is based on a pipeline of basal image processing methods like smoothing, thresholding and ellipse fitting. However, integration of application specific knowledge results in robust segmentations even in cases of image artifacts. The method is build hierarchically starting with the detection of cilia within the image, followed by the detection of nine doublets within each analyzable cilium, and ending with the detection of dynein arms of each doublet. The process is concluded by a rough classification of the dynein arms as basis for a computer-assisted diagnosis. Additionally, the interaction possibilities are designed in a way, that the results are still reproducible given the completion report. Results – A qualitative evaluation showed reasonable detection results for cilia, doublets and dynein arms. However, since a ground truth is missing, the variation of the computer-assisted diagnosis should be within the subjective bias of human diagnosticians. The results of a first quantitative evaluation with five human experts and six images with 12 analyzable cilia showed, that with default parameterization 91.6% of the cilia and 98% of the doublets were found. The computer-assisted approach rated 66% of those inner and outer dynein arms correct, where all human experts agree. However, especially the quality of the dynein arm classification may be improved in future work.
Im Rahmen der Entwicklung eines haptisch-visuellen Trainingssystems für das Fräsen am Felsenbein werden ein Haptikarm und ein autostereoskopischer 3D-Monitor genutzt, um Chirurgen die virtuelle Manipulation von knöchernen Strukturen im Kontext eines sog. Serious Game zu ermöglichen. Unter anderem sollen Assistenzärzte im Rahmen ihrer Ausbildung das Fräsen am Felsenbein für das chirurgische Einsetzen eines Cochlea-Implantats üben können. Die Visualisierung des virtuellen Fräsens muss dafür in Echtzeit und möglichst realistisch modelliert, implementiert und evaluiert werden. Wir verwenden verschiedene Raycasting Methoden mit linearer und Nearest Neighbor Interpolation und vergleichen die visuelle Qualität und die Bildwiederholfrequenzen der Methoden. Alle verglichenen Verfahren sind sind echtzeitfähig, unterscheiden sich aber in ihrer visuellen Qualität.
The evaluation and assessment of Barrett’s esophagus is challenging for both expert and nonexpert endoscopists. However, the early diagnosis of cancer in Barrett’s esophagus is crucial for its prognosis, and could save costs. Pre-clinical and clinical studies on the application of Artificial Intelligence (AI) in Barrett’s esophagus have shown promising results. In this review, we focus on the current challenges and future perspectives of implementing AI systems in the management of patients with Barrett’s esophagus.
We present the Regensburg Breast Shape Model (RBSM) – a 3D statistical shape model of the female breast built from 110 breast scans, and the first ever publicly available. Together with the model, a fully automated, pairwise surface registration pipeline used to establish correspondence among 3D breast scans is introduced. Our method is computationally efficient and requires only four landmarks to guide the registration process. In order to weaken the strong coupling between breast and thorax, we propose to minimize the variance outside the breast region as much as possible. To achieve this goal, a novel concept called breast probability masks (BPMs) is introduced. A BPM assigns probabilities to each point of a 3D breast scan, telling how likely it is that a particular point belongs to the breast area. During registration, we use BPMs to align the template to the target as accurately as possible inside the breast region and only roughly outside. This simple yet effective strategy significantly reduces the unwanted variance outside the breast region, leading to better statistical shape models in which breast shapes are quite well decoupled from the thorax. The RBSM is thus able to produce a variety of different breast shapes as independently as possible from the shape of the thorax. Our systematic experimental evaluation reveals a generalization ability of 0.17 mm and a specificity of 2.8 mm for the RBSM. Ultimately, our model is seen as a first step towards combining physically motivated deformable models of the breast and statistical approaches in order to enable more realistic surgical outcome simulation.
In this paper, we address the problem of retrospective color shading correction. An extension of the established gray-level shading correction algorithm based on signal envelope (SE) estimation to color images is developed using principal color components. Compared to the probably most general shading correction algorithm based on entropy minimization, SE estimation does not need any computationally expensive optimization and thus can be implemented more effciently. We tested our new shading correction scheme on artificial as well as real endoscopic images and observed promising results. Additionally, an indepth analysis of the stop criterion used in the SE estimation algorithm is provided leading to the conclusion that a fixed, user-defined threshold is generally not feasible. Thus, we present new ideas how to develop a non-parametric version of the SE estimation algorithm using entropy.
Die Lehre der medizinischen Bildverarbeitung vermittelt Kenntnisse mit einem breiten Methodenspektrum. Neben den Grundlagen der Verfahren soll ein Gefühl für eine geeignete Ausführungsreihenfolge und ihrer Wirkung auf medizinische Bilddaten entwickelt werden. Die Komplexität der Methoden erfordert vertiefte Programmierkenntnisse, sodass bereits einfache Operationen mit großem Programmieraufwand verbunden sind. Die Software GraphMIC stellt Bildverarbeitungsoperationen in Form interaktiver Knoten zur Verfügung und erlaubt das Arrangieren, Parametrisieren und Ausführen komplexer Verarbeitungssequenzen in einem Graphen. Durch den Fokus auf das Design einer Pipeline, weg von sprach- und frameworkspezifischen Implementierungsdetails, lassen sich grundlegende Prinzipien der Bildverarbeitung anschaulich erlernen. In diesem Beitrag stellen wir die visuelle Programmierung mit GraphMIC der nativen Implementierung äquivalenter Funktionen gegenüber. Die in C++ entwickelte Applikation basiert auf Qt, ITK, OpenCV, VTK und MITK.
The Impact of Semi-Automated Segmentation and 3D Analysis on Testing New Osteosynthesis Material
(2017)
A new protocol for testing osteosynthesis material postoperatively combining semi-automated segmentation and 3D analysis of surface meshes is proposed. By various steps of transformation and measuring, objective data can be collected. In this study the specifications of a locking plate used for mediocarpal arthrodesis of the wrist were examined. The results show, that union of the lunate, triquetrum, hamate and capitate was achieved and that the plate is comparable to coexisting arthrodesis systems. Additionally, it was shown, that the complications detected correlate to the clinical outcome. In synopsis, this protocol is considered beneficial and should be taken into account in further studies.
Backround
Scaphoidectomy and midcarpal fusion can be performed using traditional fixation methods like K-wires, staples, screws or different dorsal (non)locking arthrodesis systems. The aim of this study is to test the Aptus four corner locking plate and to compare the clinical findings to the data revealed by CT scans and semi-automated segmentation.
Methods:
This is a retrospective review of eleven patients suffering from scapholunate advanced collapse (SLAC) or scaphoid non-union advanced collapse (SNAC) wrist, who received a four corner fusion between August 2011 and July 2014. The clinical evaluation consisted of measuring the range of motion (ROM), strength and pain on a visual analogue scale (VAS). Additionally, the Disabilities of the Arm, Shoulder and Hand (QuickDASH) and the Mayo Wrist Score were assessed. A computerized tomography (CT) of the wrist was obtained six weeks postoperatively. After semi-automated segmentation of the CT scans, the models were post processed and surveyed.
Results
During the six-month follow-up mean range of motion (ROM) of the operated wrist was 60°, consisting of 30° extension and 30° flexion. While pain levels decreased significantly, 54% of grip strength and 89% of pinch strength were preserved compared to the contralateral healthy wrist. Union could be detected in all CT scans of the wrist. While X-ray pictures obtained postoperatively revealed no pathology, two user related technical complications were found through the 3D analysis, which correlated to the clinical outcome.
Conclusion
Due to semi-automated segmentation and 3D analysis it has been proved that the plate design can keep up to the manufacturers’ promises. Over all, this case series confirmed that the plate can compete with the coexisting techniques concerning clinical outcome, union and complication rate.
Purpose: In this trial, we used a previously developed prototype software to assess aesthetic results after reconstructive surgery for congenital breast asymmetry using automated anthropometry. To prove the consensus between the manual and automatic digital measurements, we evaluated the software by comparing the manual and automatic measurements of 46 breasts.
Methods: Twenty-three patients who underwent reconstructive surgery for congenital breast asymmetry at our institution were examined and underwent 3D surface imaging. Per patient, 14 manual and 14 computer-based anthropometric measurements were obtained according to a standardized protocol. Manual and automatic measurements, as well as the previously proposed Symmetry Index (SI), were compared.
Results: The Wilcoxon signed-rank test revealed no significant differences in six of the seven measurements between the automatic and manual assessments. The SI showed robust agreement between the automatic and manual methods.
Conclusion: The present trial validates our method for digital anthropometry. Despite the discrepancy in one measurement, all remaining measurements, including the SI, showed high agreement between the manual and automatic methods. The proposed data bring us one step closer to the long-term goal of establishing robust instruments to evaluate the results of breast surgery.
Virtual training of bone milling requires realtime and realistic haptics of the interaction between the ”virtual mill” and a ”virtual bone”. We propose an exponential abrasion model between a virtual one and the mill bit and combine it with a coarse representation of the virtual bone and the mill shaft for collision detection using the Bullet Physics Engine. We compare our exponential abrasion model to a widely used linear abrasion model and evaluate it quantitatively and qualitatively. The evaluation results show, that we can provide virtual milling in real-time, with an abrasion behavior similar to that proposed in the literature and with a realistic feeling of five different surgeons.
In order to fix a fracture using minimally invasive surgery approaches, surgeons are drilling complex and tiny bones with a 2 dimensional X-ray as single imaging modality in the operating room. Our novel haptic force-feedback and visual assisted training system will potentially help hand surgeons to learn the drilling procedure in a realistic visual environment. Within the simulation, the collision detection as well as the interaction between virtual drill, bone voxels and surfaces are important. In this work, the chai3d collision detection and force calculation algorithms are combined with a physics engine to simulate the bone drilling process. The chosen Bullet-Physics-Engine provides a stable simulation of rigid bodies, if the collision model of the drill and the tool holder is generated as a compound shape. Three haptic points are added to the K-wire tip for removing single voxels from the bone. For the drilling process three modes are proposed to emulate the different phases of drilling in restricting the movement of a haptic device.