Filtern
Erscheinungsjahr
Dokumenttyp
Sprache
- Englisch (18)
Schlagworte
- Lattice distortion (3)
- Superalloys (3)
- XPS (3)
- Creep deformation (2)
- Creep-deformation (2)
- Ellipsometry (2)
- SC16 (2)
- Transmission function (2)
- X-ray photoelectron spectroscopy (2)
- Bimetallic frameworks (1)
Organisationseinheit der BAM
Low biodegradability of graphene derivatives and related health risks are the main limiting factors for their in vivo biomedical applications. Here, we present the synthesis of enzyme-functionalized graphene sheets with self-degrading properties under physiological conditions and their applications in Tumor therapy. The synergistic enzyme cascade glucose oxidase and myeloperoxidase are covalently conjugated to the surface of graphene sheets and two-dimensional (2D) platforms are obtained that can produce sodium hypochlorite from glucose. The enzyme-functionalized graphene sheets with up to 289 nm average size are degraded into small pieces (≤40 nm) by incubation under physiological conditions for 24 h. Biodegradable graphene sheets are further loaded with doxorubicin and their ability for Tumor therapy is evaluated in vitro and in vivo. The laser-triggered release of doxorubicin in combination with the enzymatic activity of the functionalized graphene sheets results in a synergistic antitumor activity.
Taking advantage of their neutrophil-like activity, fast biodegradability, high photo- and chemotherapeutic effects, the novel two-dimensional nanoplatforms can be used for tumor therapeutic applications.
Specimens of single crystal superalloy SC16 were creep deformed at 1223 K along [0 0 1] up to ±0.5% creep strain using stresses of -150 MPa and +150 MPa, respectively. Line widths and peak positions of superlattice reflections were measured by means of X-ray diffraction parallel and perpendicular to the load axis in the temperature range between 293 K and 1173 K. The line widths were found to decrease with the increase of temperature for both directions on the two specimens after tensile and compressive creep deformation. After both kinds of creep deformation the crystal lattice showed tetragonal distortion which decreased with increasing temperature. The tetragonality after tensile creep deformation was larger than unity while it was smaller than unity after compressive creep deformation. The peak positions and widths restored after cooling back to room temperature. The experimental results can qualitatively be explained by the creation of dislocations during deformation and their anisotropic arrangement at the γ/γ' interfaces.
High-resolution diffraction using synchrotron x-ray radiation was applied to study γ´ precipitates with an L12 superlattice crystal structure in the single crystal superalloy SC16 after creep deformation at 1223 K with a creep strain of ±0.5% for tensile and compressive loads, respectively. The measurements of full width at half maximum (FWHM) of 001 and 100 γ´ superlattice reflections were performed at various temperatures from ambient temperature to 1173 K in vacuum. The experimental results revealed that the FWHM of both reflections decrease with increasing temperature. It is well-known that changes in particle size and lattice distortion in materials could lead to a variation of FWHM. The observed behaviour is discussed in the light of both the above-mentioned aspects. The decrease in the peak width is mainly attributed to the temperature dependence of the internal strain state.
Time dependence of y/y' Lattice Mismatch in Creep-deformed Single Crystal Superalloy SC16 at 1173 K
(2007)
Results are reported from a pilot study under the Consultative Committee for Amount of Substance (CCQM) to compare measurements of and resolve any relevant measurement issues in, the amount of thermal SiO2 oxide on (100) and (111) orientation Si wafer substrates in the thickness range 1.5 - 8 nm. As a result of the invitation to participate in this activity, 45 sets of measurements have been made in different laboratories using 10 analytical methods: medium-energy ion scattering spectrometry (MEIS), nuclear reaction analysis (NRA), RBS, elastic backscattering spectrometry (EBS), XPS, SIMS, ellipsometry, grazing-incidence x-ray reflectrometry (GIXRR), neutron reflectometry and transmission electron microscopy (TEM). The measurements are made on separate sets of 10 carefully prepared samples, all of which have been characterised by a combination of ellipsometry and XPS using carefully established reference conditions and reference parameters.
The results have been assessed against the National Physical Laboratory (NPL) data and all show excellent linearity. The remaining data sets correlate with the NPL data with average root-mean-square scatters of 0.15 nm, half being better than 0.1 nm and a few at or better than 0.05 nm. Each set of data allows a relative scaling constant and a zero thickness offset to be determined. Each method has an inherent zero thickness offset between 0 nm and 1 nm and it is these offsets, measured here for the first time, that have caused many problems in the past. There are three basic classes of offset: water and carbonadeous contamination equivalent to ~1 nm as seen by ellipsometry; adsorbed oxygen mainly from water at an equivalent thickness of 0.5 nm as seen by MEIS, NRA, RBS and possibly GIXRR; and no offset as seen by XPS using the Si 2p peaks. Each technique has a different uncertainty for the scaling constant and consistent results have been achieved. X-Ray photoelectron spectroscopy has large uncertainties for the scaling constant but a high precision and, critically, if used correctly, has zero offset. Thus, a combination of XPS and the other methods allows the XPS scaling constant to be determined with low uncertainty, traceable via the other methods. XPS laboratories returning results early were invited to test a new reference procedure. All showed very significant improvements. The reference attenuation lengths thus need scaling by 0.986 ± 0.009 (at an expansion factor of 2) deduced from the data for the other methods. Several other methods have small offsets and, to the extent that these can be shown to be constant or measurable, then these methods will also show low uncertainty. Recommendations are provided for parameters for XPS, MEIS, RBS and NRA to improve their accuracy.
The space heating system accounts for 20%~50% of building energy consumption, and may lead to energy waste due to unreasonable controls. In this study, an energy-efficient floor heating system with intelligent control was proposed to improve energy efficiency of the system. In order to validate the concept of the proposed intelligent control, an experimental system was designed and constructed in Chengdu, China. Temperature, control cycle and energy consumption were then studied under different control strategies. The result shows that a larger flow rate of supply water will result in a longer control cycle and a lower control frequency, i.e., the average control cycle at 7 L min−1 is 1.7 h during the test day, while it is 1.5 h at 5 L min−1. Moreover, adopting water with a higher temperature and flow rate could achieve a higher efficiency of the system. The energy consumptions in case 1 (5 L min−1, 50 °C), case 2 (5 L min−1, 55 °C), case 5 (7 L min−1, 55 °C) and case 6 (7 L min−1, 60 °C) are 4746 kJ, 3534 kJ, 3093 kJ and 3028 kJ, respectively. Based on the experimental data, the supply water temperature is suggested to set lower than 60 °C considering human comfort.