Filtern
Dokumenttyp
- Zeitschriftenartikel (27)
- Posterpräsentation (10)
- Beitrag zu einem Tagungsband (4)
- Vortrag (4)
- Buchkapitel (1)
- Sonstiges (1)
- Forschungsbericht (1)
Sprache
- Englisch (44)
- Deutsch (3)
- Mehrsprachig (1)
Schlagworte
- Fluorescence (16)
- Core-shell particles (6)
- Molecularly imprinted polymers (6)
- Molecular imprinting (5)
- Air quality (3)
- Air quality monitoring (3)
- Ammonia gas sensor (3)
- Environment (3)
- Glyphosate (3)
- Mesoporous silica materials (3)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (30)
- 1.9 Chemische und optische Sensorik (30)
- 8 Zerstörungsfreie Prüfung (4)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (4)
- 1.5 Proteinanalytik (3)
- 1.1 Anorganische Spurenanalytik (2)
- 4 Material und Umwelt (2)
- 4.2 Material-Mikrobiom Wechselwirkungen (2)
- 6 Materialchemie (2)
- 6.3 Strukturanalytik (2)
Paper des Monats
- ja (1)
Fluorescent sensory MIP (molecularly imprinted polymer) particles were combined with a droplet-based 3D microfluidic system for the selective determination of a prototype small-molecule analyte of environmental concern, 2,4-dichlorophenoxyacetic acid or 2,4-D, at nanomolar concentration directly in water samples. A tailor-made fluorescent indicator cross-linker was thus designed that translates the binding event directly into an enhanced fluorescence signal. The phenoxazinone-type cross-linker was co-polymerized into a thin MIP layer grafted from the surface of silica microparticles following a RAFT (reversible addition-fragmentation chain transfer) polymerization protocol. While the indicator cross-linker outperformed its corresponding monomer twin, establishment of a phase-transfer protocol was essential to guarantee that the hydrogen bond-mediated signalling mechanism between the urea binding site on the indicator cross-linker and the carboxylate group of the analyte was still operative upon real sample analysis. The latter was achieved by integration of the fluorescent core-shell MIP sensor particles into a modular microfluidic platform that allows for an in-line phasetransfer assay, extracting the analyte from aqueous sample droplets into the organic phase that contains the sensor particles. Real-time fluorescence determination of 2,4-D down to 20 nM was realized with the system and applied for the analysis of various surface water samples collected from different parts of the world.
Besides the traditional areas of application such as separation and enrichment which made molecularly imprinted polymers (MIPs) very attractive, they have emerged as a valuable detection tool in the field of environmental analysis due to the low production costs, high stability, format adaptability and the possibility to imprint and thus specifically recognize a wide variety of target analytes. Regarding optical sensing, however, MIPs have only been used in considerably few applications, especially in fluorescence sensors, basically because of the challenge to incorporate a fluorescently responding moiety into a polymer matrix. One way to overcome this limitation is the coating of a thin MIP layer onto the surface of silica nanoparticles using tailor-made fluorescent indicator monomers or cross-linkers for direct transfer of the binding event into an optical signal.
Regarding sensors for environmental monitoring, microfluidic devices utilizing optical detection modules are especially appealing because of their versatility in terms of miniaturization and automation. So far, MIPs have only rarely been used in combination with microfluidic sensor devices.
Here, we present the hydrogen bond-mediated optical response of fluorescent MIP sensor particles against a typical small-molecule analyte 2,4-D (2,4-dichlorophen¬oxyacetic acid) which is an important herbicide widely used in agriculture and known to cause adverse health effects when ingested by contaminated water. By combining the sensor particles with droplet-based 3D microfluidics, a microfluidic phase-transfer assay was designed which enables the direct analysis of 2,4-D in river and lake water without sample pre-treatment or clean-up.
Pollution through emission of toxic gases is an increasing problem for the environment. It affects similarly agricultural, industrial and urban areas. In future, environmental emissions in ambient air must be monitored at even lower concentrations as nowadays. One environmental relevant compound is ammonia and its conversion product ammonium that have strong negative impact on human health and ecosystems. Most ammonia measurements in ambient air are performed in the range below 1000 nmol·mol-1 and thus there is a need for reliable traceable ammonia gas standards and in addition in situ analytical procedures for monitoring (in ambient air to avoid that thresholds are exceeded). Therefore, the use of reference materials is necessary for development accompanying test or for calibration, e. g. of structure-integrated sensors and mobile multi-gas sensors.
The developed gas standard generator produces gas mixtures that comply with the metrological traceability for ammonia gas standards in the desired environmentally relevant measurement range. The method is based on the permeation of ammonia through a membrane at constant temperature and pressure. The resulting ammonia penetrant gas flow is then mixed with a carrier gas flow to generate a gas standard flow of known concentration. The dynamic rage is enlarged by using a two dilution steps. Depending on the permeation rate, generable molar fractions are possible in the range nmol·mol-1 to a few µmol·mol-1. We present the design of an ammonia gas standard generator and first results of the characterisation of its individual components supporting the uncertainty assessment according to GUM for stable gas concentrations in this range. The relative uncertainty of the generated ammonia gas standard is smaller than 4 % (k = 2).
Pollution through emission of toxic gases is of utmost environmental concern, raising the interest in developing reliable gas sensors. Exemplarily, ammonia and its conversion products can provoke considerable damage on human health and ecosystems. Hence, there is a need for reliable and reversible sensor materials to monitor traces of gaseous ammonia in ambient air, which at best can be used on-site for field measurements. Although various types of sensors such as potentiometric, amperometric, and biological sensors are available for detecting trace amounts of gases, fluorescent sensors have gained importance due to several advantages such as high sensitivity, possible miniaturization, as well as potential multiplexing. Herein, we present the development of a sensor material for gaseous ammonia in the lower ppm or even ppb range using optical fluorescence as transduction mechanism due to its intrinsically high sensitivity and high spatial resolution.[1] Therefore, a fluorescent dye, which shows reversible fluorescence enhancement in the presence of the analyte was incorporated into a polymer matrix, the latter to ensure the accumulation of ammonia. To calibrate the designed optical sensor system a gas standard generator was used, producing standard gas mixtures, which comply with the metrological traceability for ammonia gas standards in the desired environmentally relevant measurement range.[2] Beside the development of a highly sensitive, selective, and reversible sensor, the integration of such systems into mobile sensor devices is addressed. Therefore, a prototype of a miniaturized hand-held instrument was developed enabling a straightforward and long-term read-out of the measurement signal.
Because ammonia and its reaction products can cause considerable damage to human health and ecosystems, there is a need for reliably operating and reversibly interacting sensor materials to monitor traces of gaseous ammonia in ambient air, which at best can be used on-site for in-the-field measurements. Herein, the development of a sensor material for gaseous ammonia in the lower ppm to ppb range using optical fluorescence as transduction mechanism is presented. A fluorescent dye, which shows reversible fluorescence enhancement in the presence of ammonia is incorporated into a polymer matrix, the latter to ensure the accumulation of ammonia. The sensor material is integrated into a prototype of a miniaturized sensor device, facilitating long-term operation. To calibrate the optical sensor system a gas standard generator, producing standard gas mixtures, is used, leading to a sensitivity down to lower ppm concentrations of ammonia.
Um verlässliche Methoden für die medizinische Diagnostik und Umweltanalytik zu entwickeln sowie Zellen zu kultivieren, ist staub- bzw. keimfreies Arbeiten in einem Reinraum erforderlich. Aber was ist ein Reinraum? Viele stellen sich hier sterile Räume, keine Fenster und Personen in weißen Anzügen und Schutzmaske vor. Hier können die Besucher einen Blick hinter die Kulissen werfen und erfahren, was die Eigenschaften und Bedingungen eines Reinraumes sind und welche Anforderungen an die dort Beschäftigten gestellt werden.
Fluorescence based sensing is a versatile approach for the trace analysis outside of the laboratory, requiring suitable sensor materials and their integration into sensing devices. The versatility of fluorophores as probes, especially in terms of the possibility to tailor their optical as well as their recognition properties by synthetic modifications in a wide range, renders them a superior active component for the preparation of optical sensor devices. Recent works at BAM in this field include, for example, the detection of nerve gas agents, illustrating impressively the aforementioned benefits of fluorophores in optical sensing applications.
In the interdisciplinary approach presented here, we target hazardous gases such as ammonia, benzene, and hydrogen sulfide, next to others, which pose a major threat to human health and environmental safety and for which the availability of a sensitive and reliable detection method is highly desirable.
The dyes presented follow a “turn-on” fluorescence schematic which allows for the selective and sensitive detection of the respective gaseous analyte. The immobilization of the probe in polymeric matrices is then the next step toward the fabrication of a prototype device for molecular sensing.
Chemical functionalization for quantitative spectroscopic labeling on macroscopically flat surfaces
(2018)
This chapter highlights the application of chemical derivatization (CD) to facilitate the quantification of surface functional groups being an important issue for a wide field of applications. The selective attachment of a chemical label to a surface functional group being afterwards exclusively detectable by a highly sensitive technique overcomes the problem of characterizing low amounts of functional groups on macroscopically flat surfaces. The most frequently employed methods include CD X-ray photoelectron spectroscopy, ultraviolet/visible absorption, and fluorescence spectroscopy, as well as time-of-flight secondary ion mass spectrometry. Herein, the basic conditions for the different techniques regarding the specific surface functional group which need to be quantified are discussed. Additionally, the substrate highly influences the compatibility of the corresponding method. Because not just the quantification but also the preparation of the desired application is important, a summary of different preparation methods for glass, polymer and gold substrates is presented.
Mit Tröpfchen Spielen
(2018)
Mikrofluidische Systeme sind leistungsstarke analytische Tools mit attraktiven Eigenschaften wie miniaturisierter Größe, geringem Reagenzien und Probenverbrauch, schneller Ansprech- und kurzer Messzeit. Der Bedarf solcher leistungsstarken, miniaturisierten und direkt vor Ort anwendbaren Sensorsysteme steigt kontinuierlich, hauptsächlich durch das Bedürfnis der Gesellschaft, schneller, besser und umfassender über kritische Faktoren im Lebens- und Arbeitsumfeld sowie der Umwelt informiert zu sein.
Playing with Droplets
(2018)
Microfluidic devices are powerful analytical tools with appealing features such as miniaturized size, low reagent and sample consumption, rapid response and short measurement times. As society wants to be ever better, earlier and more comprehensively informed about critical factors in life, work, and the environment, the demand for powerful measurement devices for use outside of the laboratory constantly increases.