T cells need to adapt their cellular metabolism for effector cell differentiation. This relies on alterations in mitochondrial physiology. Which signals and molecules regulate those alterations remains unclear. We recently reported, that the mitochondrial protein TCAIM inhibits activation-induced changes in mitochondrial morphology and function and thus, CD effector T cell formation. Using conditional TCAIM knock-in (KI) and knockout (KO) mice, w now show that it also applies to CD8+ T cells and more importantly, delineate the molecular processes in mitochondria by which TCAIM controls effector cell differentiation. TCAIM KI resulted in reduced activation-induced HIF1α protein expression. Metabolomics and transcriptional data in combination with mathematical flux modeling revealed an impaired induction of anabolic pathways, especially of the mevalonate pathway and cholesterol biosynthesis in TCAIM KI CD8+ T cells. Addition of cholesterol completely rescued HIF1α protein expression, activation and proliferation of TCAIM KI CD8+ T cells. At the molecular level, TCAIM delayed activation-induced mitochondria-ER contact (MERC) formation by binding to MERC promoting proteins such as RMD3 and VDAC2. In summary, we demonstrate that TCAIM suppresses effector cell differentiation by inhibiting MERC formation, which induce HIF1α-mediated increase in cellular metabolism and cholesterol biosynthesis.
Issues that prevent Structural Health Monitoring (SHM) based on Guided Waves (GW) from being a part of today’s monitoring solutions in industry are not all obvious to the scientific community. To uncover and overcome these issues, scientists working on SHM and GW problems joined in an expert committee under the patronage of the German Society for Non-Destructive Testing. An initiated online survey among more than 700 experts and users reveals the hurdles hindering the practical application of GWbased SHM. Firstly, methods for proof of reliability of SHM approaches are missing.
Secondly, detailed understanding of phenomenological described wave-damage interactions is needed. Additionally, there are significant unsolved implementation issues and unsolved problems of signal processing including handling of environmental influences.
To enable substantial proof of reliability without unaffordable experimental effort also efficient simulation tools including realistic damage interaction are needed, enabling the joint use of experimental and simulated data to predict the capabilities of the Monitoring system. Considering these issues, the committee focusses on simulation, signal processing, as well as probability of detection and standardization. In the presented work, recent activities of the expert committee starting with survey results are summarized. An open access data basis of life-like measurements is presented to allow testing and comparison of signal processing and simulation algorithms. Finally, a strategy for efficient proof of reliability increasing the acceptance of SHM in industry and for successful Integration of SHM into real-world engineering structures is proposed.
A method, based on electrothermal vaporization (ETV) coupled to inductively coupled plasma optical emission spectrometry (ICP OES), has been optimized for direct solid sampling analysis of soda-lime glass - the most common type of industrially manufactured glass. This method allows fast and reliable quantification of the main elements - Al, Ca, K, Mg, Na, and Si - and trace elements - As, Ba, Cd, Ce, Co, Cr, Cu, Fe, Mn, Mo, Ni, (P), Pb, Sb, (Se), Sn, Sr, Ti, V, Zn, and Zr. In the presented ETV-ICP OES method, calibration is performed predominantly with matrix-free synthetic samples. This metrological advantage is normally not achieved with direct solid sampling methods and is one of the goals of the present study. In a certification interlaboratory comparison for the soda-lime glass CRM BAM-S005c, 2 out of 16 laboratories employed the ETV-ICP OES method. An improved analytical performance was obtained compared with the results of laboratories that used conventional liquid ICP OES. For both methods, the average relative deviations between the laboratory results and certified values as well as the average values of relative standard deviation were with a few exceptions <10%, in most cases even <5%, which indicated high trueness and precision.