Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (17)
- Beitrag zu einem Tagungsband (16)
- Beitrag zu einem Sammelband (6)
- Handbuch (3)
- Vortrag (3)
- Sonstiges (3)
- Forschungsbericht (3)
- Buchkapitel (1)
Schlagworte
- SAFT (11)
- Ultrasonic echo (9)
- Ultraschallecho (7)
- Korrosion (6)
- Beton (5)
- Concrete (5)
- Modellierung (5)
- Radar (5)
- Spannbeton (5)
- Imaging (4)
Organisationseinheit der BAM
Eingeladener Vortrag (wissenschaftliche Konferenzen)
- nein (3)
We concentrate on appropriate algorithmic processing of microwave Ground Penetrating Radar (GPR) data obtained from concrete specimens containing tendon ducts below steel reinforcement bars either via simulations or via experiments. The goal is to understand the physical phenomena of electromagnetic wave propagation and scattering in detail in order to optimize imaging algorithms like SAFT (Synthetic Aperture Focusing Technique as the NDT version of SAR) in its 3D diffraction tomographic FT-SAFT formulation (Fourier-Transform-SAFT). Therefore we start with the simulation of a "simple" specimen and switch to a more realistic one in order to check whether simulation and experiment can give comparable results. Basically, this could be confirmed, but, nevertheless, various parametric studies will still have to be performed in the future.
Dieses Merkblatt beschreibt die Anwendung elektrochemischer Potentialmessungen (häufig auch als Potentialfeldmessung bezeichnet) zur Detektion von Bewehrungsstahlkorrosion an Stahlbetonbauwerken. Mit Hilfe dieses Verfahrens können Bereiche korrodierender Bewehrung zerstörungsfrei lokalisiert werden. In der Regel kommt diese Messmethode bei der Detektion chloridinduzierter Korrosion zum Einsatz. In Abgrenzung hierzu sollte die Abschätzung der Gefahr einer karbonatisierungsinduzierten Korrosion durch Bestimmung der Karbonatisierungstiefe und der Betondeckung erfolgen.
Das Förderprojekt CTSimU2 baute auf den Ergebnissen des Projektes CTSimU auf. Dieses Vorprojekt erarbeitete ein (Basis-)Qualifizierungsframework für Simulationssoftwares zur Anwendung bei der Röntgen-CT für dimensionelle Messungen. Dabei stand die ausreichende physikalische Korrektheit der Durchstrahlungssimulation im Vordergrund. Für die realitätsnahe Simulation einer CT-Anlage in einer Simulationssoftware (Digitales Modell) ist jedoch nicht nur die Korrektheit der Simulationssoftware selbst, sondern auch die Güte der Parametrisierung des realen CT-Systems in der Simulationssoftware entscheidend – dies stellte den Ausgangspunkt dar. Die Parametrisierung eines CT-Systems in einer Simulationssoftware lässt sich in vier Schritte unterteilen: nach der Datenaufnahme am realen CT-System folgt die Auswertung der aufgenommenen Daten für die Generierung allgemeiner Parameterangaben. Als letztes folgte die Übertragung der Parameter in die spezifischen Simulationssoftwares und die Validierung der resultierenden Simulationsparameter. Die Methodik der Datenaufnahme am CT und die Auswertung der Daten wurde in einem Werkzeugkasten allgemein beschrieben. Der dritte Schritt, die Umsetzung der Parameter, war softwarespezifisch und wurde beispielhaft mit den vorhandenen Simulationssoftwares durchgeführt. Die Validierung der Parameter war standardisierbar und konnte durch den entwickelten Test geleistet werden, auf dessen Basis die ausreichend korrekte Simulation einer realen Anlage beurteilt werden konnte. Endresultat des Projektes war ein Richtlinienentwurf (z. B. VDI/VDE 2630) zu diesem Test, der einen informativen Annex zum Stand der Technik bezüglich der Möglichkeiten zur Parameterbestimmung enthält. Mit einer Simulationssoftware, die die Basisqualifizierung aus CTSimU bestanden hat und einen Parameterdatensatz für ein reales CT-System enthält, der den Test aus CTSimU2 bestanden hat, können realistische Simulationen dieses CT-Systems möglich sein.
Electrochemical half-cell potential measurements for the detection of reinforcement corrosion
(2014)
This specification describes the application of electrochemical half‐cell potential measurements (frequently also called potential mapping) for the detection of reinforcement corrosion in reinforced concrete structures. Areas of corroding reinforcement steel can be located in a nondestructive manner by means of this procedure. Half‐cell potential measurements are used in order to detect chloride‐induced corrosion. However, it is not recommended in order to assess the risk of carbonation‐induced corrosion. For this purpose the determination of the carbonation depth and the concrete cover appear to be more appropriate.
The content of this specification exclusively refers to the application of mobile, local variable reference electrodes, which are only placed on the concrete surface while measuring. The technique distinguishes itself thereby from the range of corrosion monitoring systems with stationary installed reference electrodes and sensor systems, respectively, whereby it is possible to continuously track measurements within the area of the installed electrodes. However, these methods are not dealt with in this specification.
Inhalt ist die zerstörungsfreie Detailuntersuchung von Holzbauteilen mit einem dreidimensional abbildenden Ultraschall-Echoverfahren. Das neu entwickelte 3D-Verfahren berücksichtigt den anisotropen Aufbau des Holzes. Die Bildschnitte und Projektionen werden aus flächigen Ultraschallaufnahmen berechnet. Die Messungen erfolgen an Probekörpern sowie an Bauteilen aus der Praxis. In dem Forschungsvorhaben wird die für Holz neue 3D-Rekonstruktionsrechnung verwendet und mit dem Ziel weiterentwickelt, unter Berücksichtigung der anisotropen Struktur des Holzes eine dreidimensional aufgelöste Abbildung von Reflektoren im Inneren der Holzbauteile zu ermöglichen. Damit werden die bisher für Holzbauteile zur Verfügung stehenden Verfahren entscheidend ergänzt, weil nun eine hochgenaue dreidimensionale Abbildung erreichbar ist (Auflösung: 20 mm und besser).
This paper presents the progress of successful location of grouting faults in tendon ducts with ultrasonic imaging. The examples were obtained in the research group FOR 384 funded by DFG (German Research Foundation). The co-operation of experimental research and modeling allowed imaging and identification of grouted and ungrouted areas of tendon ducts (including strands) in a large test specimen (40 m²). In addition to the criteria for indicating grouting faults in post-tensioned ducts known until now the phase evaluation of reflected ultrasonic pulses is described. Experiments and modeling of wave propagation are presented for reflections at metal plates in concrete (thickness range 0.5 mm to 40 mm) and for tendon ducts including strands.
The main part of the progress was achieved by automated measurements using dry contact transducers, 3D-SAFT reconstruction including phase evaluation and modeling considering wave propagation for typical elastic parameters and exact experimental site conditions. The results for shear waves as well as for pressure waves are compared in the frequency range from 50 kHz to 120 kHz.