Reduction on the spot: Planarly adsorbed thiolated porphyrin molecules (purple) incorporated in an insulating alkanethiol monolayer (blue) function as nanoelectrodes for the local reduction of metals (gray). This approach was applied for the in situ synthesis of nanoparticles of a predetermined size.
Während in einem konventionellen Ultraschallprüfkopf ein Kunststoffdämpfungskörper mit Kleber oder Öl an einen Piezoschwinger angekoppelt ist, werden als Hochtemperaturlösung feinporöse sintermetallische Dämpfungsmaterialien mit einer Flüssigglasankopplung eingesetzt. Um dabei das Sintermetall vor dem korrosiven Angriff der Glasschmelze zu schützten, wird am Dämpfungskörper gegenwärtig Gold- oder Platinfolie zeit- und kostenaufwendig appliziert.
In der aktuellen Arbeit wurde eine Methode zum Korrosionsschutz der sintermetallischen Oberfläche aus rostfreiem Stahl mittels Laser-Pulverauftragschweißen entwickelt. Im Laufe einer Schweißparameterstudie auf dem Substratmaterial aus massivem rostfreiem Stahl wurde die Eignung unterschiedlicher Auftragsmaterialien auf Nickel- und Kobaltbasis untersucht. Dabei wurde zunächst der Einfluss verschiedener Schweißparameter wie Laserleistung, Vorschubgeschwindigkeit und Pulvermenge auf die Auftragsqualität (Nahtform, Vermischungsgrad, Porosität) metallografisch bewertet. Anschließend wurden die aufgetragenen Schichten hinsichtlich ihrer Korrosionsbeständigkeit getestet. Der Kontakt mit einer flüssigen Glasmischung bei 500 °C hat bei keiner der beschichteten Proben sichtbare Korrosionswirkung gezeigt. Als Resultat der Schweißparameterstudie haben sich besonders die nickelbasierten
Pulver als gut geeignete Materialien für den Prozess gezeigt. Die identifizierten Schweißparameter wurden im nächsten Schritt erfolgreich an das sintermetallische Substrat angepasst.
Ultrasonic probes for high-temperature applications are provided with metallic wedges, which can withstand the contact with the high temperature of the inspected structure. The ultrasonic signal travels within the wedge and gets reflected from its boundaries, causing interference signals called “ghost echoes”. The current work presents an investigation of the additional damping effect provided by porous sintered metal plates applied onto the surface of the wedge. In particular, the study evaluates the effect of damping plate thickness on the interference signal level at different transmission frequencies. Damping plates made of sintered metal SIKA-R 15 AX were attached to a wedge prototype made of steel 1.4301. The study revealed, that the most effective thickness of damping plates in the selected frequency interval of 1 to 4 MHz is equal to 4 mm. The evaluation of the interference signal has shown that the application of such damping plates to the wedge surface contributes to an additional attenuation of an interference signal of 10 to 30 dB after 500 µs of signal propagation.
In the cast condition g titanium aluminide alloys that solidify completely through the b phase are
characterized by fine and homogeneous microstructures, weak textures and low segregation. For these reasons such alloys have a relatively good workability and can be closed-die forged without preceding ingot breakdown even if the alloys contain no large fractions of the b phase at the working temperature. The present work was devoted to a combined study of the constitution and microstructural morphologies that develop in various two-step heat treatments of a single-step forged b solidifying alloy. The
study included high-energy X-ray diffraction for in situ investigations of the constitution at the heat treatment temperature. It was observed that the phase ransformations are quite sluggish in the material which results in fine microstructures and some conditions that significantly deviate from thermodynamic equilibrium. Further, tensile and creep testing was carried out on the different material conditions in order to identify the range in which the properties can be varied. It is found that this easily forgeable material exhibits comparable strength, ductility and creep strength as more conventional peritectically solidifying alloys.
In special cases of angle beam ultrasonic measurement – e.g. defect detection in hot solids as well as flow measurement of liquid gases or energy storage mediums [1] – the applied transducer has to withstand extreme temperatures. Since the irradiation angle into the specific material is determined not only by wedge design, but also by the speed of sound in both the wedge material and the tested object, the developer must take into account the speed of the wave propagation in a wedge material over the whole temperature range of transducers application.
In this study we investigate the temperature dependence of the speed of longitudinal wave propagation in 10 different materials in the range from -200 °C to 400 °C. The investigated materials belong to different material classes (ceramics, glass, as well as ferrous and non-ferrous metals) and are all temperature-resistant up to at least 600 °C, and therefore applicable as wedge materials in an ultrasonic transducer for use at extreme temperatures.
Today the design processes in the aero industry face many challenges. Apart from automation itself, a suitable parametric geometry setup plays a significant role in making workflows usable for optimization. At the same time there are tough requirements against the parametric model. For the lowest number of possible parameters, which should be intuitively ascertainable, a high flexibility has to be ensured. Within the parameter range an acceptable stability is necessary. Under these constraints the creation of such parametric models is a challenge, which should not be underestimated especially for a complex geometry.
In this work different kinds of parametrization with different levels of complexity will be introduced and compared. Thereby several geometry elements will be used to handle the critical regions of the geometry. In the simplest case a combination of lines and arcs will be applied. These will be replaced by superior elements like a double arc construct or different formulations of b-splines. There will be an additional focus on the variation of spline degree and control points. To guarantee consistency a set of general parameters will be used next to the specific ones at the critical regions. The different parameter boundaries have a influence on the possible geometries and should therefore be tested separately before an optimization run.
Background: The 3D printing is relevant as a manufacturing technology of functional models for forensic, pharmaceutical and bioanalytical applications such as drug delivery systems, sample preparation and point-of-care tests.
Objective: Melting behavior and autofluorescence of materials are decisive for optimal printing and applicability of the product which are influenced by varying unknown additives.
Methods: We have produced devices for bioanalytical applications from commercially available thermoplastic polymers using a melt-layer process. We characterized them by differential scanning calorimetry, fluorescence spectroscopy and functional assays (DNA capture assay, model for cell adhesion, bacterial adhesion and biofilm formation test).
Results: From 14 tested colored, transparent and black materials we found only deep black acrylonitrile-butadiene-styrene (ABS) and some black polylactic acid (PLA) useable for fluorescence-based assays, with low autofluorescence only in the short-wave range of 300-400 nm. PLA was suitable for standard bioanalytical purposes due to a glass transition temperature of approximately 60°C, resistance to common laboratory chemicals and easy print processing. For temperature-critical methods, such as hybridization reactions up to 90°C, ABS was better suited.
Conclusions: Autofluorescence was not a disadvantage per se but can also be used as a reference signal in assays. The rapid development of individual protocols for sample processing and analysis required the availability of a material with consistent quality over time. For fluorescence-based assays, the use of commercial standard materials did not seem to meet this requirement.