Refine
Document Type
Way of publication
- Open Access (4) (remove)
Language
- English (4) (remove)
Keywords
- Biomedical applications (1)
- Corrosion (1)
- Co–Cr–Mo alloy (1)
- Friction (1)
- Nanobiomaterials (1)
- Powder metallurgy (1)
- Ringer's solution (1)
- Ti-Nb-Zr alloys (1)
- Tribological behavior (1)
- Tribology (1)
Institute
A necklace structure composed of fine grains formed by dynamic recrystallization was uncommonly observed at the pre-existing grain boundaries during the hot compression of a BCC Fe-25Al-1.5Ta alloy containing C14 - (Fe, Al)2Ta Laves phase precipitates. Two possible mechanisms for necklace formation were proposed; particle-stimulated nucleation and grain boundary bulging, depending on whether the original grain boundaries are occupied by C14 particles, or they are free of them. Recrystallization was initiated preferentially around the clusters of large particles at the boundaries containing particles. In contrast, the bulging of the original grain boundaries by strain-induced boundary migration was observed as a preliminary stage for necklace formation at the particle-free boundaries. The necklace structure expanded into the deformed volume in such a way that low-angle subgrain boundaries decorating the necklace layers transformed into grains with increasing deformation strain.
The influence of milling time on the tribological behavior of a Co–Cr–Mo alloy designed for biomedical applications, synthesized via mechanical alloying is investigated. Elemental Co, Cr and Mo powders are milled using different milling times (2, 6, 12 and 18 h) in a high-energy ball mill. The resulting powders were subjected to cold uniaxial and hot isostatic pressing respectively, followed by sintering to obtain cylindrical samples, which were evaluated for their structural, mechanical and the wear behavior. Results showed that the grain and crystallite sizes of the powders decreased with increasing milling time, reaching low values of <10 μm and 32 μm respectively, at higher milling times. Furthermore, the wear rates and the coefficients of friction were lower, at higher milling times due to high densities (96%), and higher elasto-plastic resistance, as presented by the H/E and H3/E2 values of 0.026 and 0.0021 GPa, respectively. Increased milling time enables the refinement of grains and reduction in porosity in the Co–Cr–Mo alloy, which in turn increases the alloy's elasto-plastic resistance and enhances its wear resistance.
In order to create alloys with exceptional properties for orthopedic uses, this study focuses on the impact of zirconium (Zr) content on the structural, electrochemical, and tribological qualities of nanostructured Ti–25Nb-xZr [x = 5, 10, 15, 20, 25, and 30 atomic (at.) %] alloys. The structural evolution was investigated using XRD and SEM techniques. The mechanical characteristics of the produced alloys, including Vickers hardness and Young's modulus, were measured. In addition, the corrosion tests were performed using the OCP, EIS, and PD methods in Ringer's solution within the independent pH range at 37 °C. A ball-on-disc tribometer was used to investigate the tribological behavior of the alloys under various loads and wet conditions using the Ringer solution. It has been verified that Zr content (at. %) in the alloys had an impact on their morphologies, structural evolution, and mechanical characteristics. According to the morphological analysis, the particle and crystallite size decreases with increasing Zr content. Young's modulus and Vickers hardness show the same tendency. The EIS data demonstrated that a single passive film formed on the alloy surfaces, and the addition of Zr enhanced the corrosion resistance of the passive films. The polarization curves demonstrate that the alloys had low corrosion current densities and large passive areas without the passive films disintegrating. Likewise, the inclusion of Zr resulted in a reduction in the corrosion and passive current densities values. All of these results suggested that the titanium alloys exhibit a more noble electrochemical activity caused by Zr. From the tribological perspective, it was found that the friction coefficient of the alloys reduced with increasing Zr content.
This study investigates the in vitro biocompatibility, corrosion resistance, and adhesion strength of a gas abrasive-treated Ti6Al4V alloy, alongside microplasma-sprayed titanium and tantalum coatings. Employing a novel approach in selecting microplasma spray parameters, this study successfully engineers coatings with tailored porosity, roughness, and over 20% porosity with pore sizes up to 200 μm, aiming to enhance bone in-growth and implant integration. This study introduces an innovative methodology for quantifying surface roughness using laser electron microscopy and scanning electron microscopy, facilitating detailed morphological analysis of both the substrate and coatings. Extensive evaluations, including tests for in vitro biocompatibility, corrosion resistance, and adhesive strength, revealed that all three materials are biocompatible, with tantalum coatings exhibiting superior cell proliferation and osteogenic differentiation, as well as the highest corrosion resistance. Titanium coatings followed closely, demonstrating favorable osteogenic properties and enhanced roughness, which is crucial for cell behavior and attachment. These coatings also displayed superior tensile adhesive strengths (27.6 ± 0.9 MPa for Ti and 28.0 ± 4.9 MPa for Ta), surpassing the ISO 13179-1 standard and indicating a robust bond with the substrate. Our findings offer significant advancements in biomaterials for medical implants, introducing microplasma spraying as a versatile tool for customizing implant coatings, particularly emphasizing the superior performance of tantalum coatings in terms of biocompatibility, osteogenic potential, and corrosion resistance. This suggests that tantalum coatings are a promising alternative for enhancing the performance of metal implants, especially in applications demanding high biocompatibility and corrosion resistance.