68-XX COMPUTER SCIENCE (For papers involving machine computations and programs in a specific mathematical area, see Section -04 in that area)
Refine
Year of publication
Document Type
- ZIB-Report (46)
- Master's Thesis (6)
- Software (4)
- Article (1)
- Bachelor's Thesis (1)
Keywords
- Ubiquity Generator Framework (3)
- Computational Diagnosis (2)
- Convex Optimization (2)
- Discrete optimization (2)
- Knee Osteoarthritis (2)
- Lattice problem (2)
- Lattice-based cryptography (2)
- MSM (2)
- Machine Learning (2)
- Parallel algorithms (2)
Institute
- Mathematical Optimization (23)
- Visual and Data-centric Computing (14)
- Visual Data Analysis (11)
- Applied Algorithmic Intelligence Methods (7)
- Mathematics of Telecommunication (7)
- Numerical Mathematics (5)
- Distributed Algorithms and Supercomputing (4)
- Mathematical Optimization Methods (3)
- Computational Molecular Design (2)
- Digital Data and Information for Society, Science, and Culture (2)
The goal of quantitative photoacoustic tomography (qPAT) is to recover maps of the chromophore distributions from multiwavelength images of the initial pressure. Model-based inversions that incorporate the physical processes underlying the photoacoustic (PA) signal generation represent a promising approach. Monte-Carlo models of the light transport are computationally expensive, but provide accurate fluence distributions predictions, especially in the ballistic and quasi-ballistic regimes. Here, we focus on the inverse problem of 3D qPAT of blood oxygenation and investigate the application of the Monte-Carlo method in a model-based inversion scheme. A forward model of the light transport based on the MCX simulator and acoustic propagation modeled by the k-Wave toolbox was used to generate a PA image data set acquired in a tissue phantom over a planar detection geometry. The combination of the optical and acoustic models is shown to account for limited-view artifacts. In addition, the errors in the fluence due to, for example, partial volume artifacts and absorbers immediately adjacent to the region of interest are investigated. To accomplish large-scale inversions in 3D, the number of degrees of freedom is reduced by applying image segmentation to the initial pressure distribution to extract a limited number of regions with homogeneous optical parameters. The absorber concentration in the tissue phantom was estimated using a coordinate descent parameter search based on the comparison between measured and modeled PA spectra. The estimated relative concentrations using this approach lie within 5 % compared to the known concentrations. Finally, we discuss the feasibility of this approach to recover the blood oxygenation from experimental data.