65M50 Mesh generation and refinement
Refine
Document Type
- ZIB-Report (6)
Language
- English (6)
Has Fulltext
- yes (6)
Is part of the Bibliography
- no (6)
Keywords
- human mandible (2)
- Gitterlose Methoden (1)
- KARDOS (1)
- Kopplung (1)
- adaptive finite elements (1)
- anisotropy (1)
- bony organ simulation (1)
- civil engineering (1)
- discretization error (1)
- elasticity (1)
Institute
- Numerical Mathematics (6) (remove)
Spectral Deferred Correction methods for adaptive electro-mechanical coupling in cardiac simulation
(2014)
We investigate spectral deferred correction (SDC) methods for time stepping
and their interplay with spatio-temporal adaptivity, applied to the solution
of the cardiac electro-mechanical coupling model. This model consists
of the Monodomain equations, a reaction-diffusion system modeling the cardiac
bioelectrical activity, coupled with a quasi-static mechanical model describing
the contraction and relaxation of the cardiac muscle. The numerical
approximation of the cardiac electro-mechanical coupling is a challenging
multiphysics problem, because it exhibits very different spatial and temporal
scales. Therefore, spatio-temporal adaptivity is a promising approach
to reduce the computational complexity. SDC methods are simple iterative
methods for solving collocation systems. We exploit their flexibility for combining
them in various ways with spatio-temporal adaptivity. The accuracy
and computational complexity of the resulting methods are studied on some
numerical examples.
In contrast to the well known meshbased methods like the finite element method, meshfree methods do not rely on a mesh. However besides their great applicability, meshfree methods are rather time consuming. Thus, it seems favorable to combine both methods, by using meshfree methods only in a small part of the domain, where a mesh is disadvantageous, and a meshbased method for the rest of the domain. We motivate, that this coupling between the two simulation techniques can be considered as saddle point problem and show the stability of this coupling. Thereby a novel transfer operator is introduced, which interacts in the transition zone, where both methods coexist.
Pulse thermography of concrete structures is used in civil engineering for detecting voids, honeycombing and delamination. The physical situation is readily modeled by Fourier's law. Despite the simplicity of the PDE structure, quantitatively realistic numerical 3D simulation faces two major obstacles. First, the short heating pulse induces a thin boundary layer at the heated surface which encapsulates all information and therefore has to be resolved faithfully. Even with adaptive mesh refinement techniques, obtaining useful accuracies requires an unsatisfactorily fine discretization. Second, bulk material parameters and boundary conditions are barely known exactly. We address both issues by a semi-analytic reformulation of the heat transport problem and by parameter identification. Numerical results are compared with measurements of test specimens.
Parabolic reaction-diffusion systems may develop sharp moving reaction fronts which pose a challenge even for adaptive finite element methods. We propose a method to transform the equation into an equivalent form that usually exhibits solutions which are easier to discretize, giving higher accuracy for a given number of degrees of freedom. The transformation is realized as an efficiently computable pointwise nonlinear scaling that is optimized for prototypical planar travelling wave solutions of the underlying reaction-diffusion equation. The gain in either performance or accuracy is demonstrated on different numerical examples.
Structural mechanics simulation of bony organs is of general medical and biomechanical interest, because of the interdependence of the inner architecture of bone and its functional loading already stated by Wolff in 1892. This work is part of a detailed research project concerning the human mandible. By adaptive finite element techniques, stress/strain profiles occurring in the bony structure under biting were simulated. Estimates of the discretization errors, local grid refinement, and multilevel techniques guarantee the reliability and efficiency of the method. In general, our simulation requires a representation of the organ's geometry, an appropriate material description, and the load case due to teeth, muscle, or joint forces. In this paper, we want to focus on the influence of the masticatory system. Our goal is to capture the physiological situation as far as possible. By means of visualization techniques developed by the group, we are able to extract individual muscle fibres from computed tomography data. By a special algorithm, the fibres are expanded to fanlike (esp. for the musc. temporalis) coherent vector fields similar to the anatomical reality. The activity of the fibres can be adapted according to compartmentalisation of the muscles as measured by electromyological experiments. A refined sensitivity analysis proved remarkable impact of the presented approach on the simulation results.
We focus on the role of anisotropic elasticity in the simulation of the load distribution in a human mandible due to a lateral bite on the leftmost premolar. Based on experimental evidence, we adopt ``local''" orthotropy of the elastic properties of the bone tissue. Since the trajectories of anisotropic elasticity are not accessible from Computer Tomographic (CT) data, they will be reconstructed from (i) the organ's geometry and (ii) from coherent structures which can be recognized from the spatial distribution of the CT values. A sensitivity analysis comprising various 3D FE simulations reveals the relevance of elastic anisotropy for the load carrying behavior of a human mandible: Comparison of the load distributions in isotropic and anisotropic simulations indicates that anisotropy seems to ``spare''" the mandible from loading. Moreover, a maximum degree of anisotropy leads to kind of an load minimization of the mandible, expressed by a minimum of different norms of local strain, evaluated throughout the organ. Thus, we may suggest that anisotropy is not only relevant, but also in some sense ``optimal''.