In this paper, we present a software-assisted workflow for the alignment and matching of filamentous structures across a stack of 3D serial image sections. This is achieved by a combination of automatic methods, visual validation, and interactive correction. After an initial alignment, the user can continuously improve the result by interactively correcting landmarks or matches of filaments. This is supported by a quality assessment that visualizes regions that have been already inspected and, thus, allows a trade-off between quality and manual labor.
The software tool was developed in collaboration with biologists who investigate microtubule-based spindles during cell division. To quantitatively understand the structural organization of such spindles, a 3D reconstruction of the numerous microtubules is essential. Each spindle is cut into a series of semi-thick physical sections, of which electron tomograms are acquired. The sections then need to be stitched, i.e. non-rigidly aligned; and the microtubules need to be traced in each section and connected across section boundaries. Experiments led to the conclusion that automatic methods for stitching alone provide only an incomplete solution to practical analysis needs. Automatic methods may fail due to large physical distortions, a low signal-to-noise ratio of the images, or other unexpected experimental difficulties. In such situations, semi-automatic validation and correction is required to rescue as much information as possible to derive biologically meaningful results despite of some errors related to data collection.
Since the correct stitching is visually not obvious due to the number of microtubules (up to 30k) and their dense spatial arrangement, these are difficult tasks. Furthermore, a naive inspection of each microtubule is too time consuming. In addition, interactive visualization is hampered by the size of the image data (up to 100 GB). Based on the requirements of our collaborators, we present a practical solution for the semi-automatic stitching of serial section image stacks with filamentous structures.
Quantitative photoacoustic tomography aims to recover maps of the local concentrations of tissue chromophores from multispectral images. While model-based inversion schemes are promising approaches, major challenges to their practical implementation include the unknown fluence distribution and the scale of the inverse problem. This paper describes an inversion scheme based on a radiance Monte Carlo model and an adjoint-assisted gradient optimization that incorporates fluence-dependent step sizes and adaptive moment estimation. The inversion is shown to recover absolute chromophore concentrations, blood oxygen saturation and the Grüneisen parameter from in silico 3D phantom images for different radiance approximations. The scattering coefficient was assumed to be homogeneous and known a priori.
Quantitative PA tomography of high resolution 3-D images: experimental validation in tissue phantoms
(2019)
Quantitative photoacoustic tomography aims recover the spatial distribution of absolute chromophore concentrations and their ratios from deep tissue, high-resolution images. In this study, a model-based inversion scheme based on a Monte-Carlo light transport model is experimentally validated on 3-D multispectral images of a tissue phantom acquired using an all-optical scanner with a planar detection geometry. A calibrated absorber allowed scaling of the measured data during the inversion, while an acoustic correction method was employed to compensate the effects of limited view detection. Chromophore- and fluence-dependent step sizes and Adam optimization were implemented to achieve rapid convergence. High resolution 3-D maps of absolute concentrations and their ratios were recovered with high accuracy. Potential applications of this method include quantitative functional and molecular photoacoustic tomography of deep tissue in preclinical and clinical studies.
Following axon pathfinding, growth cones transition from stochastic filopodial exploration to the formation of a limited number of synapses. How the interplay of filopodia and synapse assembly ensures robust connectivity in the brain has remained a challenging problem. Here, we developed a new 4D analysis method for filopodial dynamics and a data-driven computational model of synapse formation for R7 photoreceptor axons in developing Drosophila brains. Our live data support a 'serial synapse formation' model, where at any time point only a single 'synaptogenic' filopodium suppresses the synaptic competence of other filopodia through competition for synaptic seeding factors. Loss of the synaptic seeding factors Syd-1 and Liprin-α leads to a loss of this suppression, filopodial destabilization and reduced synapse formation, which is sufficient to cause the destabilization of entire axon terminals. Our model provides a filopodial 'winner-takes-all' mechanism that ensures the formation of an appropriate number of synapses.