Temperature-based estimation of time of death (ToD) can be per-
formed either with the help of simple phenomenological models of corpse
cooling or with detailed mechanistic (thermodynamic) heat transfer mod-
els. The latter are much more complex, but allow a higher accuracy of
ToD estimation as in principle all relevant cooling mechanisms can be
taken into account.
The potentially higher accuracy depends on the accuracy of tissue and
environmental parameters as well as on the geometric resolution. We in-
vestigate the impact of parameter variations and geometry representation
on the estimated ToD based on a highly detailed 3D corpse model, that
has been segmented and geometrically reconstructed from a computed to-
mography (CT) data set, differentiating various organs and tissue types.
Temperature based death time estimation is based either on simple phenomenological models of corpse cooling or on detailed physical heat transfer models. The latter are much more complex, but allow a higher accuracy of death time estimation as in principle all relevant cooling mechanisms can be taken into account. Here, a complete work flow for finite element based cooling simulation models is presented.
The following steps are demonstrated on CT-phantoms:
• CT-scan
• Segmentation of the CT images for thermodynamically relevant features of individual
geometries
• Conversion of the segmentation result into a Finite Element (FE) simulation model
• Computation of the model cooling curve
• Calculation of the cooling time
For the first time in FE-based cooling time estimation the steps from the CT image over segmentation to FE model generation are semi-automatically performed. The cooling time calculation results are compared to cooling measurements performed on the phantoms under controlled conditions. In this context, the method is validated using different CTphantoms. Some of the CT phantoms thermodynamic material parameters had to be experimentally determined via independent experiments. Moreover the impact of geometry and material parameter uncertainties on the estimated cooling time is investigated by a sensitivity analysis.