Refine
Document Type
- Article (5)
- In Proceedings (2)
- ZIB-Report (2)
Language
- English (9)
Is part of the Bibliography
- no (9)
Keywords
Institute
Introduction: Anterior knee pain and other patello-femoral (PF) complications frequently limit the success of total knee arthroplasty as the final treatment of end stage osteoarthritis. However, knowledge about the in-vivo loading conditions at the PF joint remains limited, as no direct measurements are available. We hypothesised that the external knee flexion moment (EFM) is highly predictive of the PF contact forces during activities with substantial flexion of the loaded knee.
Materials and methods: Six patients (65–80 years, 67–101 kg) with total knee arthroplasty (TKA) performed two activities of daily living: sit-stand-sit and squat. Tibio-femoral (TF) contact forces were measured in vivo using instrumented tibial components, while synchronously internal TF and PF kinematics were captured with mobile fluoroscopy. The measurements were used to compute PF contact forces using patient specific musculoskeletal models. The relationship between the EFM and the PF contact force was quantified using linear regression.
Results: Mean peak TF contact forces of 1.97–3.24 times body weight (BW) were found while peak PF forces reached 1.75 to 3.29 times body weight (BW). The peak EFM ranged from 3.2 to 5.9 %BW times body height, and was a good predictor of the PF contact force (R2 = 0.95 and 0.88 for sit-stand-sit and squat, respectively).
Discussion: The novel combination of in vivo TF contact forces and internal patellar kinematics enabled a reliable assessment of PF contact forces. The results of the regression analysis suggest that PF forces can be estimated based solely on the EFM from quantitative gait analysis. Our study also demonstrates the relevance of PF contact forces, which reach magnitudes similar to TF forces during activities of daily living.
OBJECTIVES:
To evaluate the reliability of the modified Radiographic Union Score for Tibial fractures (mRUST) as a reliable tool for monitoring lower limb fractures (femur, tibia) treated with various modalities (nail, plate).
METHODS:
Design:
Retrospective analysis.
Setting:
Single center academic hospital in Germany.
Patient Selection Criteria:
Adult patients (≥18 years) with extra-articular long bone fractures of the lower extremities treated surgically between January 2005 and April 2022, requiring radiographs in two perpendicular planes and at least one follow-up visit, were included. Exclusion criteria were critical clinical conditions, inability to consent, joint articulation fractures, inadequate documentation, or insufficient imaging quality.
Outcome Measures and Comparisons:
Six international investigators (five orthopedic surgeons, one radiologist) independently assessed fracture line and callus growth per cortex (mRUST) at individualized follow-up time points based on clinical practice. To evaluate interrater reliability, intraclass correlation coefficients were calculated for the overall dataset, and for subsets of rated images, that were defined based on anatomical location (femur/tibia), treatment type (plate/nail fixation), and treatment combinations across locations.
RESULTS:
A total of 166 patients (63 femur fractures, 103 tibia fractures; 32.5% female, mean age 43.4 (18–84)) with 1136 follow-up time points were analyzed. Overall interrater reliability for mRUST was good (intraclass correlation coefficient 0.77), consistent across fixation methods (nail/plate fixation, 0.79) and anatomical locations (tibia, 0.78; femur, 0.81). Cortex-specific reliability varied, with highest agreement for the medial cortex (0.70–0.74) and lowest for the posterior cortex (0.65–0.74).
CONCLUSIONS:
The mRUST (radiographic score) demonstrated reliability for monitoring fracture healing in the femur and tibia, irrespective of fixation method, supporting its use as a generalizable tool across lower limb fractures.
LEVEL OF EVIDENCE:
Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
Callus formation during healing is guided by local strain: a retrospective clinical observation
(2026)
Abstract
Background
Clinically, fracture healing is typically monitored though serial radiographs. Specifically, callus development (growth and mineralization) is an indicator of healing and associated with local mechanical strain. However, a sustainable relationship between mechanical conditions and the respective healing progress has not been shown so far.
Material and methods
One hundred sixty-six patients with extra-articular lower-limb fractures treated by osteosynthesis plates or intramedullary nails were included. Callus formation (visible area in X-ray relative to bone shaft) and quality (image intensity relative to the cortex) were measured by consecutive X-ray analyses as well as the modified Radiographic Union-Score for Tibia (mRUST) during follow-up. Corresponding load- and fixation-matched finite element analysis (FEA) modelling was developed for tibia or femur loading as well as plate or intramedullary nail fixation. Mechanical strains (medially, laterally, dorsally, anteriorly) were evaluated from FEA and compared to the progress in X-ray callus formation and quality to perform a correlation analysis between observed callus formation and simulated local mechanical strains.
Results
For femoral fractures, callus size was largest dorso-medially (1.41 ± 1.57 cm
2
/cm and 1.18 ± 1.11 cm
2
/cm at 180 ± 45 days post-surgery) while largest callus formations were found laterally in tibial fractures (0.75 ± 0.49 cm
2
/cm at 365 ± 45 days post-surgery). These locations of maximal callus size in femur and tibia matched the locations of extreme principal strains from FEA. In femur, callus density increased steadily and exceeded cortex density at 365 ± 45 days post-surgery. For tibia, no such clear trend was observable. While initially showing a similar increase in callus bridging score mRUST, increase over 2 years was 48% higher for the tibial fractures compared to femoral fractures. While principal strains correspond to increases in early callus formation in both femur and tibia (Kendall-Tau-b:
p
= 0.021 for volumetric strain at 90 ± 45 days post-surgery), shear strains are consistently associated with less callus formation (Kendall-Tau-b:
p
= 0.048 for volumetric/shear strain associated with callus size*density at 365 ± 45 days post-surgery).
Conclusions
Callus formation during bone healing may be associated with local mechanical strain in lower limb fractures within a clinically relevant cohort including different fracture locations and fixation types. Shear strain at the fracture site appeared to be associated with reduced quality callus formation, whereas principal strain was observed to correlate with increased early callus formation. The presented methodology may have potential as a predictor of healing processes and could help identify mechanically challenging fracture fixation settings.
Level of evidence
II.
Trial registration
Ethical approval was obtained from the local ethics board to this retrospective study design (EA4/099/24).
We present a novel method to derive the surface distance of an osteosynthesis plate w.r.t. the patientspecific surface of the distal femur based on 2D Xray images. Our goal is to study from clinical data, how the platetobone distance affects bone healing. The patientspecific 3D shape of the femur is, however, seldom recorded for cases of femoral osteosynthesis since this typically requires Computed Tomography (CT), which comes at high cost and radiation dose. Our method instead utilizes two postoperative Xray images to derive the femoral shape and thus can be applied on radiographs that are taken in clinical routine for followup. First, the implant geometry is used as a calibration object to relate the implant and the individual Xray images spatially in a virtual Xray setup. In a second step, the patientspecific femoral shape and pose are reconstructed in the virtual setup by fitting a deformable statistical shape and intensity model (SSIM) to the images. The relative positioning between femur and implant is then assessed in terms of displacement between the reconstructed 3D shape of the femur and the plate. A preliminary evaluation based on 4 cadaver datasets shows that the method derives the platetobone distance with a mean absolute error of less than 1mm and a maximum error of 4.7 mm compared to ground truth from CT. We believe that the approach presented in this paper constitutes a meaningful tool to elucidate the effect of implant positioning on fracture healing.
We present a novel method to derive the surface distance of an osteosynthesis plate w.r.t. the patient-specific surface of the distal femur based on postoperative 2D radiographs. In a first step, the implant geometry is used as a calibration object to relate the implant and the individual X-ray images spatially in a virtual X-ray setup. Second, the patient-specific femoral shape and pose are reconstructed by fitting a deformable statistical shape and intensity model (SSIM) to the X-rays. The relative positioning between femur and implant is then assessed in terms of the displacement between the reconstructed 3D shape of the femur and the plate. We believe that the approach presented in this paper constitutes a meaningful tool to elucidate the effect of implant positioning on fracture healing and, ultimately, to derive load recommendations after surgery.
We present a novel method to derive the surface distance of an osteosynthesis plate w.r.t. the patientspecific surface of the distal femur based on 2D Xray images. Our goal is to study from clinical data, how the platetobone distance affects bone healing. The patientspecific 3D shape of the femur is, however, seldom recorded for cases of femoral osteosynthesis since this typically requires Computed Tomography (CT), which comes at high cost and radiation dose. Our method instead utilizes two postoperative Xray images to derive the femoral shape and thus can be applied on radiographs that are taken in clinical routine for followup. First, the implant geometry is used as a calibration object to relate the implant and the individual Xray images spatially in a virtual Xray setup. In a second step, the patientspecific femoral shape and pose are reconstructed in the virtual setup by fitting a deformable statistical shape and intensity model (SSIM) to the images. The relative positioning between femur and implant is then assessed in terms of displacement between the reconstructed 3D shape of the femur and the plate. A preliminary evaluation based on 4 cadaver datasets shows that the method derives the platetobone distance with a mean absolute error of less than 1mm and a maximum error of 4.7 mm compared to ground truth from CT. We believe that the approach presented in this paper constitutes a meaningful tool to elucidate the effect of implant positioning on fracture healing.
We present a novel method to derive the surface distance of an osteosynthesis plate w.r.t. the patient-specific surface of the distal femur based on postoperative 2D radiographs. In a first step, the implant geometry is used as a calibration object to relate the implant and the individual X-ray images spatially in a virtual X-ray setup. Second, the patient- specific femoral shape and pose are reconstructed by fitting a deformable statistical shape and intensity model (SSIM) to the X-rays. The relative positioning between femur and implant is then assessed in terms of the displacement between the reconstructed 3D shape of the femur and the plate. We believe that the approach presented in this paper constitutes a meaningful tool to elucidate the effect of implant positioning on fracture healing and, ultimately, to derive load recommendations after surgery.
Anterior knee pain and other patello-femoral (PF) complications frequently limit the success of total knee arthroplasty as the final treatment of end stage osteoarthritis. However, knowledge about the invivo loading conditions at the PF joint remains limited, as no direct measurements are available. We hypothesised that the external knee flexion moment (EFM) is highly predictive of the PF contact forces during activities with substantial flexion of the loaded knee.Six patients (65-80 years, 67-101 kg) with total knee arthroplasty (TKA) performed two activities of daily living: sit-stand-sit and squat. Tibio-femoral (TF) contact forces were measured in vivo using instrumented tibial components, while synchronously internal TF and PF kinematics were captured with mobile fluoroscopy. The measurements were used to compute PF contact forces using patient specific musculoskeletal models. The
relationship between the EFM and the PF contact force was quantified using linear regression.Mean peak TF contact forces of 1.97 to 3.24 times body weight (BW) were found while peak PF forces reached 1.75 to 3.29 times body weight (BW). The peak EFM ranged from 3.2 to 5.9 %BW times body height, and was a good predictor of the PF contact force (R^2 = 0.95 and 0.88 for sit-standsit and squat, respectively).The novel combination of in vivo TF contact forces and internal patellar kinematics enabled a reliable assessment of PF contact forces. The results of the regression analysis suggest that PF forces can be estimated based solely on the EFM from quantitative gait analysis. Our study also demonstrates the relevance of PF contact forces, which reach magnitudes similar to TF forces during activities of daily living.