CFD analysis in an anatomically realistic coronary artery model based on non-invasive 3D imaging
(2008)
Characterization of an artificial valve flow using the numerical dye washout visualization technique
(2006)
This study’s objective was the generation of a standardized geometry of the healthy nasal cavity.
An average geometry of the healthy nasal cavity was generated using a statistical shape model based on 25 symptom-free subjects. Airflow within the average geometry and these geometries was calculated using fluid simulations. Integral measures of the nasal resistance, wall shear stresses (WSS) and velocities were calculated as well as cross-sectional areas (CSA). Furthermore, individual WSS and static pressure distributions were mapped onto the average geometry.
The average geometry featured an overall more regular shape that resulted in less resistance, reduced wall shear stresses and velocities compared to the median of the 25 geometries. Spatial distributions of WSS and pressure of average geometry agreed well compared to the average distributions of all individual geometries. The minimal CSA of the average geometry was larger than the median of all individual geometries (83.4 vs. 74.7 mm²).
The airflow observed within the average geometry of the healthy nasal cavity did not equal the average airflow of the individual geometries. While differences observed for integral measures were notable, the calculated values for the average geometry lay within the distributions of the individual parameters. Spatially resolved parameters differed less prominently.
Successful functional surgery on the nasal framework requires reliable and comprehensive diagnosis. In this regard, the authors introduce a new methodology: Digital Analysis of Nasal Airflow (diANA). It is based on computational fluid dynamics, a statistical shape model of the healthy nasal cavity and rhinologic expertise. diANA necessitates an anonymized tomographic dataset of the paranasal sinuses including the complete nasal cavity and, when available, clinical information. The principle of diANA is to compare the morphology and the respective airflow of an individual nose with those of a reference. This enablesmorphometric aberrations and consecutive flow field anomalies to localize and quantify within a patient’s nasal cavity. Finally, an elaborated expert opinion with instructive visualizations is provided. Using diANA might support surgeons in decision-making, avoiding unnecessary surgery, gaining more precision, and target-orientation for indicated operations.
Impact of imaging modality for analysis of a cerebral aneurysm: Comparison between CT, MRI and 3DRA
(2008)
Hunterian ligation affecting hemodynamics in vessels was proposed to avoid rebleeding in a case of a fenestrated basilar artery aneurysm after incomplete coil occlusion. We studied the hemodynamics in vitro to predict the hemodynamic changes near the aneurysm remnant caused by Hunterian ligation. A transparent model was fabricated based on three-dimensional rotational angiography imaging. Arteries were segmented and reconstructed. Pulsatile flow in the artery segments near the partially occluded (coiled) aneurysm was investigated by means of particle image velocimetry. The hemodynamic situation was investigated before and after Hunterian ligation of either the left or the right vertebral artery (LVA/RVA). Since post-ligation flow rate in the basilar artery was unknown, reduced and retained flow rates were simulated for both ligation options. Flow in the RVA and in the corresponding fenestra vessel is characterized by a vortex at the vertebrobasilar junction, whereas the LVA exhibits undisturbed laminar flow. Both options (RVA or LVA ligation) cause a significant flow reduction near the aneurysm remnant with a retained flow rate. The impact of RVA ligation is, however, significantly higher. This in vitro case study shows that flow reduction near the aneurysm remnant can be achieved by Hunterian ligation and that this effect depends largely on the selection of the ligated vessel. Thus the ability of the proposed in vitro pipe-line to improve hemodynamic impact of the proposed therapy was successfully proved.