Refine
Year of publication
Document Type
- Article (17)
- ZIB-Report (5)
- In Proceedings (4)
- Poster (4)
- Book chapter (1)
- Other (1)
Is part of the Bibliography
- no (32)
Keywords
- Articulated Models, Statistical Shape And Intensity Models, 2D/3D Anatomy Reconstruction, Pelvic Parameters Measurement, Total Hip Arthroplasty (2)
- image registration (2)
- 3D reconstruction (1)
- Digitally Reconstructed Radiograph (DRR), Anatomy Reconstruction, Statistical Shape and Intensity Model (SSIM), GPU acceleration (1)
- GPU acceleration (1)
- acetabular orientation (1)
- articulated shape and intensity models (1)
- bone anchored hearing implant (1)
- digitally reconstructed radiographs (1)
- mesh deformation (1)
Acetabular bone defects are still challenging to quantify. Numerous classification schemes have been proposed to categorize the diverse kinds of defects. However, these classification schemes are mainly descriptive and hence it remains difficult to apply them in pre-clinical testing, implant development and pre-operative planning. By reconstructing the native situation of a defect pelvis using a Statistical Shape Model (SSM), a more quantitative analysis of the bone defects could be performed. The aim of this study is to develop such a SSM and to validate its accuracy using relevant clinical scenarios and parameters.
Die Positionierung des B-FMT der Vibrant Bonebridge kann aufgrund der anatomischen Verhältnisse des Mastoids und der Größe des Aktuators ohne eine vorherige Beurteilung der individuellen Computertomographie (CT) des Felsenbeins problematisch sein. Die Entwicklung eines einfach zu bedienenden Viewers, welcher eine Positionierung des B-FMT im Felsenbeinmodell ermöglicht und hier auf individuelle potenzielle anatomische Konflikte hinweist sowie Lösungsmöglichkeiten anbietet, kann ein hilfreiches Werkzeug zur präoperativen Positionierung sein.
Ziel der Arbeit war die Definition von Anforderungen und die Anfertigung eines Prototyps eines Vibrant-Bonebridge-Viewers.
Auf der Basis einer ZIBAmira-Software-Version und der Inklusion eines B-FMT-Modells unter Erstellung eines Felsenbeinmodells, welches die intuitive Beurteilung von Konflikten ermöglicht, erfolgte die Erstellung des Prototyps eines Vibrant-Bonebridge-Viewers.Ergebnisse. Die Segmentierungszeit der individuellen DICOM-Daten („digital imaging and communications in medicine“) beträgt etwa 5 min. Eine Positionierung im individuellen 3-D-Felsenbeinmodell ermöglicht die quantitative und qualitative Beurteilung von Konflikten (Sinus sigmoideus, mittlere Schädelgrube) und das Aufsuchen einer bevorzugten Position. Das Anheben des B-FMT mittels virtueller Unterlegscheiben kann simuliert werden.
Der erstellte Vibrant-Bonebridge-Viewer ermöglicht verlässlich eine Simulation der B-FMT-Positionierung. Die klinische Anwendbarkeit muss evaluiert werden.
Information about the temporal bone size and variations of anatomical structures are crucial for a safe positioning of the Vibrant Bonebridge B-FMT. A radiological based preoperative planning of the surgical procedure decreases the surgical time and minimizes the risk of complications.
We developed a software tool, which allows a catch up of foreign DICOM data based CT temporal bone scans. The individual CT scan is transmitted into a 3D reconstructed pattern of the temporal bone. In this 3D reconstruction the individually favored position of the B- FMT should be found.
The software allows a determination of a safe B-FMT position by identifying the individual relation of middle fossa, jugular bulb and external auditory canal. Skull thickness and screw length are contained parameters for the surgical planning.
An easy to handle software tool allows a radiologically data based safe and fast surgical positioning of the B-FMT.
We propose a novel GPU-based approach to render virtual X-ray projections of deformable tetrahedral meshes. These meshes represent the shape and the internal density distribution of a particular anatomical structure and are derived from statistical shape and intensity models (SSIMs). We apply our method to improve the geometric reconstruction of 3D anatomy (e.g.\ pelvic bone) from 2D X-ray images. For that purpose, shape and density of a tetrahedral mesh are varied and virtual X-ray projections are generated within an optimization process until the similarity between the computed virtual X-ray and the respective anatomy depicted in a given clinical X-ray is maximized. The OpenGL implementation presented in this work deforms and projects tetrahedral meshes of high resolution (200.000+ tetrahedra) at interactive rates. It generates virtual X-rays that accurately depict the density distribution of an anatomy of interest. Compared to existing methods that accumulate X-ray attenuation in deformable meshes, our novel approach significantly boosts the deformation/projection performance. The proposed projection algorithm scales better with respect to mesh resolution and complexity of the density distribution, and the combined deformation and projection on the GPU scales better with respect to the number of deformation parameters. The gain in performance allows for a larger number of cycles in the optimization process. Consequently, it reduces the risk of being stuck in a local optimum. We believe that our approach contributes in orthopedic surgery, where 3D anatomy information needs to be extracted from 2D X-rays to support surgeons in better planning joint replacements.
We present a software planning tool that provides intuitive visual feedback for finding suitable positions of hearing implants in the human temporal bone. After an automatic reconstruction of the temporal bone anatomy the tool pre-positions the implant and allows the user to adjust its position interactively with simple 2D dragging and rotation operations on the bone's surface. During this procedure, visual elements like warning labels on the implant or color encoded bone density information on the bone geometry provide guidance for the determination of a suitable fit.
Towards Robust Measurement of Pelvic Parameters from AP Radiographs using Articulated 3D Models
(2015)
Patient-specific parameters such as the orientation of the acetabulum or pelvic tilt are useful for custom planning for total hip arthroplasty (THA) and for evaluating the outcome of surgical interventions. The gold standard in obtaining pelvic parameters is from three-dimensional (3D) computed tomography (CT) imaging. However, this adds time and cost, exposes the patient to a substantial radiation dose, and does not allow for imaging under load (e.g. while the patient is standing). If pelvic parameters could be reliably derived from the standard anteroposterior (AP) radiograph, preoperative planning would be more widespread, and research analyses could be applied to retrospective data, after a postoperative issue is discovered. The goal of this work is to enable robust measurement of two surgical parameters of interest: the tilt of the anterior pelvic plane (APP) and the orientation of the natural acetabulum. We present a computer-aided reconstruction method to determine the APP and natural acetabular orientation from a single, preoperative X-ray. It can easily be extended to obtain other important preoperative and postoperative parameters solely based on a single AP radiograph.