We present a unified approach for consistent remeshing of arbitrary non-manifold triangle meshes with additional user-defined feature lines, which together form a feature skeleton. Our method is based on local operations only and produces meshes of high regularity and triangle quality while preserving the geometry as well as topology of the feature skeleton and the input mesh.
Purpose: Despite the success of total knee arthroplasty there continues to be a significant proportion of patients who are dissatisfied. One explanation may be a shape mismatch between pre and post-operative distal femurs. The purpose of this study was to investigate a method to match a statistical shape model (SSM) to intra-operatively acquired point cloud data from a surgical navigation system, and to validate it against the pre-operative magnetic resonance imaging (MRI) data from the same patients.
Methods: A total of 10 patients who underwent navigated total knee arthroplasty also had an MRI scan less than 2 months pre-operatively. The standard surgical protocol was followed which included partial digitization of the distal femur. Two different methods were employed to fit the SSM to the digitized point cloud data, based on (1) Iterative Closest Points (ICP) and (2) Gaussian Mixture Models (GMM). The available MRI data were manually segmented and the reconstructed three-dimensional surfaces used as ground truth against which the statistical shape model fit was compared.
Results: For both approaches, the difference between the statistical shape model-generated femur and the surface generated from MRI segmentation averaged less than 1.7 mm, with maximum errors occurring in less clinically important areas.
Conclusion: The results demonstrated good correspondence with the distal femoral morphology even in cases of sparse data sets. Application of this technique will allow for measurement of mismatch between pre and post-operative femurs retrospectively on any case done using the surgical navigation system and could be integrated into the surgical navigation unit to provide real-time feedback.
Die Positionierung des B-FMT der Vibrant Bonebridge kann aufgrund der anatomischen Verhältnisse des Mastoids und der Größe des Aktuators ohne eine vorherige Beurteilung der individuellen Computertomographie (CT) des Felsenbeins problematisch sein. Die Entwicklung eines einfach zu bedienenden Viewers, welcher eine Positionierung des B-FMT im Felsenbeinmodell ermöglicht und hier auf individuelle potenzielle anatomische Konflikte hinweist sowie Lösungsmöglichkeiten anbietet, kann ein hilfreiches Werkzeug zur präoperativen Positionierung sein.
Ziel der Arbeit war die Definition von Anforderungen und die Anfertigung eines Prototyps eines Vibrant-Bonebridge-Viewers.
Auf der Basis einer ZIBAmira-Software-Version und der Inklusion eines B-FMT-Modells unter Erstellung eines Felsenbeinmodells, welches die intuitive Beurteilung von Konflikten ermöglicht, erfolgte die Erstellung des Prototyps eines Vibrant-Bonebridge-Viewers.Ergebnisse. Die Segmentierungszeit der individuellen DICOM-Daten („digital imaging and communications in medicine“) beträgt etwa 5 min. Eine Positionierung im individuellen 3-D-Felsenbeinmodell ermöglicht die quantitative und qualitative Beurteilung von Konflikten (Sinus sigmoideus, mittlere Schädelgrube) und das Aufsuchen einer bevorzugten Position. Das Anheben des B-FMT mittels virtueller Unterlegscheiben kann simuliert werden.
Der erstellte Vibrant-Bonebridge-Viewer ermöglicht verlässlich eine Simulation der B-FMT-Positionierung. Die klinische Anwendbarkeit muss evaluiert werden.