TY - GEN A1 - Gupta, Pooja A1 - Gramatke, Annika A1 - Einspanier, Ralf A1 - Schütte, Christof A1 - von Kleist, Max A1 - Sharbati, Jutta T1 - In silicio cytotoxicity assessment on cultured rat intestinal cells deduced from cellular impedance measurements N2 - Early and reliable identification of chemical toxicity is of utmost importance. At the same time, reduction of animal testing is paramount. Therefore, methods that improve the interpretability and usability of in vitro assays are essential. xCELLigence’s real-time cell analyzer (RTCA) provides a novel, fast and cost effective in vitro method to probe compound toxicity. We developed a simple mathematical framework for the qualitative and quantitative assessment of toxicity for RTCA measurements. Compound toxicity, in terms of its 50% inhibitory concentration IC_{50} on cell growth, and parameters related to cell turnover were estimated on cultured IEC-6 cells exposed to 10 chemicals at varying concentrations. Our method estimated IC50 values of 113.05, 7.16, 28.69 and 725.15 μM for the apparently toxic compounds 2-acetylamino-fluorene, aflatoxin B1, benzo-[a]-pyrene and chloramphenicol in the tested cell line, in agreement with literature knowledge. IC_{50} values of all apparent in vivo non-toxic compounds were estimated to be non-toxic by our method. Corresponding estimates from RTCA’s in-built model gave false positive (toxicity) predictions in 5/10 cases. Taken together, our proposed method reduces false positive predictions and reliably identifies chemical toxicity based on impedance measurements. The source code for the developed method including instructions is available at https://git.zib.de/bzfgupta/toxfit/tree/master. T3 - ZIB-Report - 17-08 KW - Real-time cell analyzer KW - Toxicity KW - Mathematical modeling KW - IC_{50} Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-62666 SN - 1438-0064 ER - TY - JOUR A1 - Klus, Stefan A1 - Nüske, Feliks A1 - Koltai, Peter A1 - Wu, Hao A1 - Kevrekidis, Ioannis A1 - Schütte, Christof A1 - Noé, Frank T1 - Data-driven model reduction and transfer operator approximation JF - Journal of Nonlinear Science Y1 - 2018 UR - https://link.springer.com/article/10.1007/s00332-017-9437-7 U6 - https://doi.org/10.1007/s00332-017-9437-7 VL - 28 IS - 3 SP - 985 EP - 1010 ER - TY - JOUR A1 - Koltai, Peter A1 - Ciccotti, Giovanni A1 - Schütte, Christof T1 - On Markov state models for non-equilibrium molecular dynamics JF - The Journal of Chemical Physics Y1 - 2016 U6 - https://doi.org/10.1063/1.4966157 N1 - 2016 Editor's Choice of The Journal of Chemical Physics VL - 145 IS - 174103 ER - TY - JOUR A1 - Gelß, Patrick A1 - Matera, Sebastian A1 - Schütte, Christof T1 - Solving the master equation without kinetic Monte Carlo: Tensor train approximations for a CO oxidation model JF - Journal of Computational Physics N2 - In multiscale modeling of heterogeneous catalytic processes, one crucial point is the solution of a Markovian master equation describing the stochastic reaction kinetics. Usually, this is too high-dimensional to be solved with standard numerical techniques and one has to rely on sampling approaches based on the kinetic Monte Carlo method. In this study we break the curse of dimensionality for the direct solution of the Markovian master equation by exploiting the Tensor Train Format for this purpose. The performance of the approach is demonstrated on a first principles based, reduced model for the CO oxidation on the RuO2(110) surface. We investigate the complexity for increasing system size and for various reaction conditions. The advantage over the stochastic simulation approach is illustrated by a problem with increased Y1 - 2016 U6 - https://doi.org/10.1016/j.jcp.2016.03.025 VL - 314 SP - 489 EP - 502 ER - TY - JOUR A1 - Vega, Iliusi A1 - Schütte, Christof A1 - Conrad, Tim T1 - Finding metastable states in real-world time series with recurrence networks JF - Physica A: Statistical Mechanics and its Applications N2 - In the framework of time series analysis with recurrence networks, we introduce a self-adaptive method that determines the elusive recurrence threshold and identifies metastable states in complex real-world time series. As initial step, we introduce a way to set the embedding parameters used to reconstruct the state space from the time series. We set them as the ones giving the maximum Shannon entropy of the diagonal line length distribution for the first simultaneous minima of recurrence rate and Shannon entropy. To identify metastable states, as well as the transitions between them, we use a soft partitioning algorithm for module finding which is specifically developed for the case in which a system shows metastability. We illustrate our method with a complex time series example. Finally, we show the robustness of our method for identifying metastable states. Our results suggest that our method is robust for identifying metastable states in complex time series, even when introducing considerable levels of noise and missing data points. Y1 - 2016 U6 - https://doi.org/10.1016/j.physa.2015.10.041 VL - 445 SP - 1 EP - 17 ER - TY - JOUR A1 - Conrad, Tim A1 - Genzel, Martin A1 - Cvetkovic, Nada A1 - Wulkow, Niklas A1 - Leichtle, Alexander Benedikt A1 - Vybiral, Jan A1 - Kytyniok, Gitta A1 - Schütte, Christof T1 - Sparse Proteomics Analysis – a compressed sensing-based approach for feature selection and classification of high-dimensional proteomics mass spectrometry data JF - BMC Bioinfomatics N2 - Background: High-throughput proteomics techniques, such as mass spectrometry (MS)-based approaches, produce very high-dimensional data-sets. In a clinical setting one is often interested in how mass spectra differ between patients of different classes, for example spectra from healthy patients vs. spectra from patients having a particular disease. Machine learning algorithms are needed to (a) identify these discriminating features and (b) classify unknown spectra based on this feature set. Since the acquired data is usually noisy, the algorithms should be robust against noise and outliers, while the identified feature set should be as small as possible. Results: We present a new algorithm, Sparse Proteomics Analysis (SPA),based on thet heory of compressed sensing that allows us to identify a minimal discriminating set of features from mass spectrometry data-sets. We show (1) how our method performs on artificial and real-world data-sets, (2) that its performance is competitive with standard (and widely used) algorithms for analyzing proteomics data, and (3) that it is robust against random and systematic noise. We further demonstrate the applicability of our algorithm to two previously published clinical data-sets. Y1 - 2017 U6 - https://doi.org/10.1186/s12859-017-1565-4 VL - 18 IS - 160 ER - TY - JOUR A1 - Rüdrich, S. A1 - Sarich, Marco A1 - Schütte, Christof T1 - Utilizing hitting times for finding metastable sets in non-reversible Markov chains JF - Journal of Comp. Dynamics Y1 - 2017 ER - TY - JOUR A1 - Gupta, Pooja A1 - Gramatke, Annika A1 - Einspanier, Ralf A1 - Schütte, Christof A1 - von Kleist, Max A1 - Sharbati, Jutta T1 - In silico cytotoxicity assessment on cultured rat intestinal cells deduced from cellular impedance measurements JF - Toxicology in Vitro N2 - Early and reliable identification of chemical toxicity is of utmost importance. At the same time, reduction of animal testing is paramount. Therefore, methods that improve the interpretability and usability of in vitro assays are essential. xCELLigence’s real-time cell analyzer (RTCA) provides a novel, fast and cost effective in vitro method to probe compound toxicity. We developed a simple mathematical framework for the qualitative and quantitative assessment of toxicity for RTCA measurements. Compound toxicity, in terms of its 50% inhibitory concentration IC50 on cell growth, and parameters related to cell turnover were estimated on cultured IEC-6 cells exposed to 10 chemicals at varying concentrations. Our method estimated IC50 values of 113.05, 7.16, 28.69 and 725.15 μM for the apparently toxic compounds 2-acetylamino-fluorene, aflatoxin B1, benzo-[a]-pyrene and chloramphenicol in the tested cell line, in agreement with literature knowledge. IC50 values of all apparent in vivo non-toxic compounds were estimated to be non-toxic by our method. Corresponding estimates from RTCA’s in-built model gave false positive (toxicity) predictions in 5/10 cases. Taken together, our proposed method reduces false positive predictions and reliably identifies chemical toxicity based on impedance measurements. The source code for the developed method including instructions is available at https://git.zib.de/bzfgupta/toxfit/tree/master. KW - Real-time cell analyzer KW - Toxicity KW - Mathematical modeling Y1 - 2017 SN - 1438-0064 VL - 41 SP - 179 EP - 188 ER - TY - JOUR A1 - Klus, Stefan A1 - Gelß, Patrick A1 - Peitz, Sebastian A1 - Schütte, Christof T1 - Tensor-based dynamic mode decomposition JF - Nonlinearity Y1 - 2018 U6 - https://doi.org/10.1088/1361-6544/aabc8f VL - 31 IS - 7 PB - IOP Publishing Ltd & London Mathematical Society ER - TY - JOUR A1 - Weber, Marcus A1 - Fackeldey, Konstantin A1 - Schütte, Christof T1 - Set-Free Markov State Model Building JF - Journal of Chemical Physics Y1 - 2017 U6 - https://doi.org/10.1063/1.4978501 VL - 146 IS - 12 ER -