TY - CHAP A1 - Estacio, Laura A1 - Ehlke, Moritz A1 - Tack, Alexander A1 - Castro-Gutierrez, Eveling A1 - Lamecker, Hans A1 - Mora, Rensso A1 - Zachow, Stefan T1 - Unsupervised Detection of Disturbances in 2D Radiographs T2 - 2021 IEEE 18th International Symposium on Biomedical Imaging (ISBI) N2 - We present a method based on a generative model for detection of disturbances such as prosthesis, screws, zippers, and metals in 2D radiographs. The generative model is trained in an unsupervised fashion using clinical radiographs as well as simulated data, none of which contain disturbances. Our approach employs a latent space consistency loss which has the benefit of identifying similarities, and is enforced to reconstruct X-rays without disturbances. In order to detect images with disturbances, an anomaly score is computed also employing the Frechet distance between the input X-ray and the reconstructed one using our generative model. Validation was performed using clinical pelvis radiographs. We achieved an AUC of 0.77 and 0.83 with clinical and synthetic data, respectively. The results demonstrated a good accuracy of our method for detecting outliers as well as the advantage of utilizing synthetic data. Y1 - 2021 U6 - https://doi.org/10.1109/ISBI48211.2021.9434091 SP - 367 EP - 370 ER - TY - JOUR A1 - Sahu, Manish A1 - Mukhopadhyay, Anirban A1 - Zachow, Stefan T1 - Simulation-to-Real domain adaptation with teacher-student learning for endoscopic instrument segmentation JF - International Journal of Computer Assisted Radiology and Surgery N2 - Purpose Segmentation of surgical instruments in endoscopic video streams is essential for automated surgical scene understanding and process modeling. However, relying on fully supervised deep learning for this task is challenging because manual annotation occupies valuable time of the clinical experts. Methods We introduce a teacher–student learning approach that learns jointly from annotated simulation data and unlabeled real data to tackle the challenges in simulation-to-real unsupervised domain adaptation for endoscopic image segmentation. Results Empirical results on three datasets highlight the effectiveness of the proposed framework over current approaches for the endoscopic instrument segmentation task. Additionally, we provide analysis of major factors affecting the performance on all datasets to highlight the strengths and failure modes of our approach. Conclusions We show that our proposed approach can successfully exploit the unlabeled real endoscopic video frames and improve generalization performance over pure simulation-based training and the previous state-of-the-art. This takes us one step closer to effective segmentation of surgical instrument in the annotation scarce setting. Y1 - 2021 U6 - https://doi.org/10.1007/s11548-021-02383-4 N1 - Honorary Mention: Machine Learning for Computer-Assisted Intervention (CAI) Award @IPCAI2021 N1 - Honorary Mention: Audience Award for Best Innovation @IPCAI2021 VL - 16 SP - 849 EP - 859 PB - Springer Nature ER - TY - JOUR A1 - Tack, Alexander A1 - Preim, Bernhard A1 - Zachow, Stefan T1 - Fully automated Assessment of Knee Alignment from Full-Leg X-Rays employing a "YOLOv4 And Resnet Landmark regression Algorithm" (YARLA): Data from the Osteoarthritis Initiative JF - Computer Methods and Programs in Biomedicine N2 - We present a method for the quantification of knee alignment from full-leg X-Rays. A state-of-the-art object detector, YOLOv4, was trained to locate regions of interests (ROIs) in full-leg X-Ray images for the hip joint, the knee, and the ankle. Residual neural networks (ResNets) were trained to regress landmark coordinates for each ROI.Based on the detected landmarks the knee alignment, i.e., the hip-knee-ankle (HKA) angle, was computed. The accuracy of landmark detection was evaluated by a comparison to manually placed landmarks for 360 legs in 180 X-Rays. The accuracy of HKA angle computations was assessed on the basis of 2,943 X-Rays. Results of YARLA were compared to the results of two independent image reading studies(Cooke; Duryea) both publicly accessible via the Osteoarthritis Initiative. The agreement was evaluated using Spearman's Rho, and weighted kappa as well as regarding the correspondence of the class assignment (varus/neutral/valgus). The average difference between YARLA and manually placed landmarks was less than 2.0+- 1.5 mm for all structures (hip, knee, ankle). The average mismatch between HKA angle determinations of Cooke and Duryea was 0.09 +- 0.63°; YARLA resulted in a mismatch of 0.10 +- 0.74° compared to Cooke and of 0.18 +- 0.64° compared to Duryea. Cooke and Duryea agreed almost perfectly with respect to a weighted kappa value of 0.86, and showed an excellent reliability as measured by a Spearman's Rho value of 0.99. Similar values were achieved by YARLA, i.e., a weighted kappa value of0.83 and 0.87 and a Spearman's Rho value of 0.98 and 0.99 to Cooke and Duryea,respectively. Cooke and Duryea agreed in 92% of all class assignments and YARLA did so in 90% against Cooke and 92% against Duryea. In conclusion, YARLA achieved results comparable to those of human experts and thus provides a basis for an automated assessment of knee alignment in full-leg X-Rays. Y1 - 2021 U6 - https://doi.org/https://doi.org/10.1016/j.cmpb.2021.106080 VL - 205 IS - 106080 ER - TY - JOUR A1 - Ambellan, Felix A1 - Zachow, Stefan A1 - von Tycowicz, Christoph T1 - Rigid Motion Invariant Statistical Shape Modeling based on Discrete Fundamental Forms JF - Medical Image Analysis N2 - We present a novel approach for nonlinear statistical shape modeling that is invariant under Euclidean motion and thus alignment-free. By analyzing metric distortion and curvature of shapes as elements of Lie groups in a consistent Riemannian setting, we construct a framework that reliably handles large deformations. Due to the explicit character of Lie group operations, our non-Euclidean method is very efficient allowing for fast and numerically robust processing. This facilitates Riemannian analysis of large shape populations accessible through longitudinal and multi-site imaging studies providing increased statistical power. Additionally, as planar configurations form a submanifold in shape space, our representation allows for effective estimation of quasi-isometric surfaces flattenings. We evaluate the performance of our model w.r.t. shape-based classification of hippocampus and femur malformations due to Alzheimer's disease and osteoarthritis, respectively. In particular, we achieve state-of-the-art accuracies outperforming the standard Euclidean as well as a recent nonlinear approach especially in presence of sparse training data. To provide insight into the model's ability of capturing biological shape variability, we carry out an analysis of specificity and generalization ability. Y1 - 2021 U6 - https://doi.org/10.1016/j.media.2021.102178 VL - 73 ER - TY - GEN A1 - Grewe, C. Martin A1 - Zachow, Stefan T1 - Release of the FexMM for the Open Virtual Mirror Framework N2 - THIS MODEL IS FOR NON-COMMERCIAL RESEARCH PURPOSES. ONLY MEMBERS OF UNIVERSITIES OR NON-COMMERCIAL RESEARCH INSTITUTES ARE ELIGIBLE TO APPLY. 1. Download, fill, and sign the form available from: https://media.githubusercontent.com/media/mgrewe/ovmf/main/data/fexmm_license_agreement.pdf 2. Send the signed form to: fexmm@zib.de NOTE: Use an official email address of your institution for the request. Y1 - 2021 U6 - https://doi.org/10.12752/8532 ER - TY - JOUR A1 - von Lindheim, Johannes A1 - Harikrishnan, Abhishek A1 - Dörffel, Tom A1 - Klein, Rupert A1 - Koltai, Peter A1 - Mikula, Natalia A1 - Müller, Annette A1 - Névir, Peter A1 - Pacey, George A1 - Polzin, Robert A1 - Vercauteren, Nikki T1 - Definition, detection and tracking of persistent structures in atmospheric flows JF - arXiv N2 - Long-lived flow patterns in the atmosphere such as weather fronts, mid-latitude blockings or tropical cyclones often induce extreme weather conditions. As a consequence, their description, detection, and tracking has received increasing attention in recent years. Similar objectives also arise in diverse fields such as turbulence and combustion research, image analysis, and medical diagnostics under the headlines of "feature tracking", "coherent structure detection" or "image registration" - to name just a few. A host of different approaches to addressing the underlying, often very similar, tasks have been developed and successfully used. Here, several typical examples of such approaches are summarized, further developed and applied to meteorological data sets. Common abstract operational steps form the basis for a unifying framework for the specification of "persistent structures" involving the definition of the physical state of a system, the features of interest, and means of measuring their persistence. Y1 - 2021 ER - TY - JOUR A1 - Tack, Alexander A1 - Ambellan, Felix A1 - Zachow, Stefan T1 - Towards novel osteoarthritis biomarkers: Multi-criteria evaluation of 46,996 segmented knee MRI data from the Osteoarthritis Initiative JF - PLOS One N2 - Convolutional neural networks (CNNs) are the state-of-the-art for automated assessment of knee osteoarthritis (KOA) from medical image data. However, these methods lack interpretability, mainly focus on image texture, and cannot completely grasp the analyzed anatomies’ shapes. In this study we assess the informative value of quantitative features derived from segmentations in order to assess their potential as an alternative or extension to CNN-based approaches regarding multiple aspects of KOA. Six anatomical structures around the knee (femoral and tibial bones, femoral and tibial cartilages, and both menisci) are segmented in 46,996 MRI scans. Based on these segmentations, quantitative features are computed, i.e., measurements such as cartilage volume, meniscal extrusion and tibial coverage, as well as geometric features based on a statistical shape encoding of the anatomies. The feature quality is assessed by investigating their association to the Kellgren-Lawrence grade (KLG), joint space narrowing (JSN), incident KOA, and total knee replacement (TKR). Using gold standard labels from the Osteoarthritis Initiative database the balanced accuracy (BA), the area under the Receiver Operating Characteristic curve (AUC), and weighted kappa statistics are evaluated. Features based on shape encodings of femur, tibia, and menisci plus the performed measurements showed most potential as KOA biomarkers. Differentiation between non-arthritic and severely arthritic knees yielded BAs of up to 99%, 84% were achieved for diagnosis of early KOA. Weighted kappa values of 0.73, 0.72, and 0.78 were achieved for classification of the grade of medial JSN, lateral JSN, and KLG, respectively. The AUC was 0.61 and 0.76 for prediction of incident KOA and TKR within one year, respectively. Quantitative features from automated segmentations provide novel biomarkers for KLG and JSN classification and show potential for incident KOA and TKR prediction. The validity of these features should be further evaluated, especially as extensions of CNN- based approaches. To foster such developments we make all segmentations publicly available together with this publication. Y1 - 2021 U6 - https://doi.org/10.1371/journal.pone.0258855 VL - 16 IS - 10 ER - TY - JOUR A1 - Tack, Alexander A1 - Shestakov, Alexey A1 - Lüdke, David A1 - Zachow, Stefan T1 - A deep multi-task learning method for detection of meniscal tears in MRI data from the Osteoarthritis Initiative database JF - Frontiers in Bioengineering and Biotechnology, section Biomechanics N2 - We present a novel and computationally efficient method for the detection of meniscal tears in Magnetic Resonance Imaging (MRI) data. Our method is based on a Convolutional Neural Network (CNN) that operates on a complete 3D MRI scan. Our approach detects the presence of meniscal tears in three anatomical sub-regions (anterior horn, meniscal body, posterior horn) for both the Medial Meniscus (MM) and the Lateral Meniscus (LM) individually. For optimal performance of our method, we investigate how to preprocess the MRI data or how to train the CNN such that only relevant information within a Region of Interest (RoI) of the data volume is taken into account for meniscal tear detection. We propose meniscal tear detection combined with a bounding box regressor in a multi-task deep learning framework to let the CNN implicitly consider the corresponding RoIs of the menisci. We evaluate the accuracy of our CNN-based meniscal tear detection approach on 2,399 Double Echo Steady-State (DESS) MRI scans from the Osteoarthritis Initiative database. In addition, to show that our method is capable of generalizing to other MRI sequences, we also adapt our model to Intermediate-Weighted Turbo Spin-Echo (IW TSE) MRI scans. To judge the quality of our approaches, Receiver Operating Characteristic (ROC) curves and Area Under the Curve (AUC) values are evaluated for both MRI sequences. For the detection of tears in DESS MRI, our method reaches AUC values of 0.94, 0.93, 0.93 (anterior horn, body, posterior horn) in MM and 0.96, 0.94, 0.91 in LM. For the detection of tears in IW TSE MRI data, our method yields AUC values of 0.84, 0.88, 0.86 in MM and 0.95, 0.91, 0.90 in LM. In conclusion, the presented method achieves high accuracy for detecting meniscal tears in both DESS and IW TSE MRI data. Furthermore, our method can be easily trained and applied to other MRI sequences. Y1 - 2021 U6 - https://doi.org/10.3389/fbioe.2021.747217 SP - 28 EP - 41 ER - TY - GEN A1 - Tack, Alexander A1 - Shestakov, Alexey A1 - Lüdke, David A1 - Zachow, Stefan T1 - A deep multi-task learning method for detection of meniscal tears in MRI data from the Osteoarthritis Initiative database N2 - We present a novel and computationally efficient method for the detection of meniscal tears in Magnetic Resonance Imaging (MRI) data. Our method is based on a Convolutional Neural Network (CNN) that operates on a complete 3D MRI scan. Our approach detects the presence of meniscal tears in three anatomical sub-regions (anterior horn, meniscal body, posterior horn) for both the Medial Meniscus (MM) and the Lateral Meniscus (LM) individually. For optimal performance of our method, we investigate how to preprocess the MRI data or how to train the CNN such that only relevant information within a Region of Interest (RoI) of the data volume is taken into account for meniscal tear detection. We propose meniscal tear detection combined with a bounding box regressor in a multi-task deep learning framework to let the CNN implicitly consider the corresponding RoIs of the menisci. We evaluate the accuracy of our CNN-based meniscal tear detection approach on 2,399 Double Echo Steady-State (DESS) MRI scans from the Osteoarthritis Initiative database. In addition, to show that our method is capable of generalizing to other MRI sequences, we also adapt our model to Intermediate-Weighted Turbo Spin-Echo (IW TSE) MRI scans. To judge the quality of our approaches, Receiver Operating Characteristic (ROC) curves and Area Under the Curve (AUC) values are evaluated for both MRI sequences. For the detection of tears in DESS MRI, our method reaches AUC values of 0.94, 0.93, 0.93 (anterior horn, body, posterior horn) in MM and 0.96, 0.94, 0.91 in LM. For the detection of tears in IW TSE MRI data, our method yields AUC values of 0.84, 0.88, 0.86 in MM and 0.95, 0.91, 0.90 in LM. In conclusion, the presented method achieves high accuracy for detecting meniscal tears in both DESS and IW TSE MRI data. Furthermore, our method can be easily trained and applied to other MRI sequences. T3 - ZIB-Report - 21-33 Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-84415 SN - 1438-0064 ER - TY - GEN A1 - Ambellan, Felix A1 - Hanik, Martin A1 - von Tycowicz, Christoph T1 - Morphomatics: Geometric morphometrics in non-Euclidean shape spaces N2 - Morphomatics is an open-source Python library for (statistical) shape analysis developed within the geometric data analysis and processing research group at Zuse Institute Berlin. It contains prototype implementations of intrinsic manifold-based methods that are highly consistent and avoid the influence of unwanted effects such as bias due to arbitrary choices of coordinates. KW - shape analysis KW - geometric statistics KW - geometric morphometrics Y1 - 2021 U6 - https://doi.org/10.12752/8544 N1 - https://morphomatics.github.io/ ER - TY - CHAP A1 - Ambellan, Felix A1 - Zachow, Stefan A1 - von Tycowicz, Christoph T1 - Geodesic B-Score for Improved Assessment of Knee Osteoarthritis T2 - Proc. Information Processing in Medical Imaging (IPMI) N2 - Three-dimensional medical imaging enables detailed understanding of osteoarthritis structural status. However, there remains a vast need for automatic, thus, reader-independent measures that provide reliable assessment of subject-specific clinical outcomes. To this end, we derive a consistent generalization of the recently proposed B-score to Riemannian shape spaces. We further present an algorithmic treatment yielding simple, yet efficient computations allowing for analysis of large shape populations with several thousand samples. Our intrinsic formulation exhibits improved discrimination ability over its Euclidean counterpart, which we demonstrate for predictive validity on assessing risks of total knee replacement. This result highlights the potential of the geodesic B-score to enable improved personalized assessment and stratification for interventions. Y1 - 2021 U6 - https://doi.org/10.1007/978-3-030-78191-0_14 SP - 177 EP - 188 ER - TY - JOUR A1 - Hembus, Jessica A1 - Ambellan, Felix A1 - Zachow, Stefan A1 - Bader, Rainer T1 - Establishment of a rolling-sliding test bench to analyze abrasive wear propagation of different bearing materials for knee implants JF - Applied Sciences N2 - Currently, new materials for knee implants need to be extensively and expensive tested in a knee wear simulator in a realized design. However, using a rolling-sliding test bench, these materials can be examined under the same test conditions but with simplified geometries. In the present study, the test bench was optimized, and forces were adapted to the physiological contact pressure in the knee joint using the available geometric parameters. Various polymers made of polyethylene and polyurethane articulating against test wheels made of cobalt-chromium and aluminum titanate were tested in the test bench using adapted forces based on ISO 14243-1. Polyurethane materials showed distinctly higher wear rates than polyethylene materials and showed inadequate wear resistance for use as knee implant material. Thus, the rolling-sliding test bench is an adaptable test setup for evaluating newly developed bearing materials for knee implants. It combines the advantages of screening and simulator tests and allows testing of various bearing materials under physiological load and tribological conditions of the human knee joint. The wear behavior of different material compositions and the influence of surface geometry and quality can be initially investigated without the need to produce complex implant prototypes of total knee endoprosthesis or interpositional spacers. Y1 - 2021 U6 - https://doi.org/10.3390/app11041886 VL - 11 IS - 4 ER - TY - GEN A1 - Tack, Alexander A1 - Ambellan, Felix A1 - Zachow, Stefan T1 - Towards novel osteoarthritis biomarkers: Multi-criteria evaluation of 46,996 segmented knee MRI data from the Osteoarthritis Initiative (Supplementary Material) T2 - PLOS One N2 - Convolutional neural networks (CNNs) are the state-of-the-art for automated assessment of knee osteoarthritis (KOA) from medical image data. However, these methods lack interpretability, mainly focus on image texture, and cannot completely grasp the analyzed anatomies’ shapes. In this study we assess the informative value of quantitative features derived from segmentations in order to assess their potential as an alternative or extension to CNN-based approaches regarding multiple aspects of KOA A fully automated method is employed to segment six anatomical structures around the knee (femoral and tibial bones, femoral and tibial cartilages, and both menisci) in 46,996 MRI scans. Based on these segmentations, quantitative features are computed, i.e., measurements such as cartilage volume, meniscal extrusion and tibial coverage, as well as geometric features based on a statistical shape encoding of the anatomies. The feature quality is assessed by investigating their association to the Kellgren-Lawrence grade (KLG), joint space narrowing (JSN), incident KOA, and total knee replacement (TKR). Using gold standard labels from the Osteoarthritis Initiative database the balanced accuracy (BA), the area under the Receiver Operating Characteristic curve (AUC), and weighted kappa statistics are evaluated. Features based on shape encodings of femur, tibia, and menisci plus the performed measurements showed most potential as KOA biomarkers. Differentiation between healthy and severely arthritic knees yielded BAs of up to 99%, 84% were achieved for diagnosis of early KOA. Substantial agreement with weighted kappa values of 0.73, 0.73, and 0.79 were achieved for classification of the grade of medial JSN, lateral JSN, and KLG, respectively. The AUC was 0.60 and 0.75 for prediction of incident KOA and TKR within 5 years, respectively. Quantitative features from automated segmentations yield excellent results for KLG and JSN classification and show potential for incident KOA and TKR prediction. The validity of these features as KOA biomarkers should be further evaluated, especially as extensions of CNN-based approaches. To foster such developments we make all segmentations publicly available together with this publication. Y1 - 2021 U6 - https://doi.org/10.12752/8328 N1 - 46,996 automated segmentations for data from the OAI database. VL - 16 IS - 10 ER - TY - JOUR A1 - Sekuboyina, Anjany A1 - Husseini, Malek E. A1 - Bayat, Amirhossein A1 - Löffler, Maximilian A1 - Liebl, Hans A1 - Li, Hongwei A1 - Tetteh, Giles A1 - Kukačka, Jan A1 - Payer, Christian A1 - Štern, Darko A1 - Urschler, Martin A1 - Chen, Maodong A1 - Cheng, Dalong A1 - Lessmann, Nikolas A1 - Hu, Yujin A1 - Wang, Tianfu A1 - Yang, Dong A1 - Xu, Daguang A1 - Ambellan, Felix A1 - Amiranashvili, Tamaz A1 - Ehlke, Moritz A1 - Lamecker, Hans A1 - Lehnert, Sebastian A1 - Lirio, Marilia A1 - de Olaguer, Nicolás Pérez A1 - Ramm, Heiko A1 - Sahu, Manish A1 - Tack, Alexander A1 - Zachow, Stefan A1 - Jiang, Tao A1 - Ma, Xinjun A1 - Angerman, Christoph A1 - Wang, Xin A1 - Brown, Kevin A1 - Kirszenberg, Alexandre A1 - Puybareau, Élodie A1 - Chen, Di A1 - Bai, Yiwei A1 - Rapazzo, Brandon H. A1 - Yeah, Timyoas A1 - Zhang, Amber A1 - Xu, Shangliang A1 - Hou, Feng A1 - He, Zhiqiang A1 - Zeng, Chan A1 - Xiangshang, Zheng A1 - Liming, Xu A1 - Netherton, Tucker J. A1 - Mumme, Raymond P. A1 - Court, Laurence E. A1 - Huang, Zixun A1 - He, Chenhang A1 - Wang, Li-Wen A1 - Ling, Sai Ho A1 - Huynh, Lê Duy A1 - Boutry, Nicolas A1 - Jakubicek, Roman A1 - Chmelik, Jiri A1 - Mulay, Supriti A1 - Sivaprakasam, Mohanasankar A1 - Paetzold, Johannes C. A1 - Shit, Suprosanna A1 - Ezhov, Ivan A1 - Wiestler, Benedikt A1 - Glocker, Ben A1 - Valentinitsch, Alexander A1 - Rempfler, Markus A1 - Menze, Björn H. A1 - Kirschke, Jan S. T1 - VerSe: A Vertebrae labelling and segmentation benchmark for multi-detector CT images JF - Medical Image Analysis N2 - Vertebral labelling and segmentation are two fundamental tasks in an automated spine processing pipeline. Reliable and accurate processing of spine images is expected to benefit clinical decision support systems for diagnosis, surgery planning, and population-based analysis of spine and bone health. However, designing automated algorithms for spine processing is challenging predominantly due to considerable variations in anatomy and acquisition protocols and due to a severe shortage of publicly available data. Addressing these limitations, the Large Scale Vertebrae Segmentation Challenge (VerSe) was organised in conjunction with the International Conference on Medical Image Computing and Computer Assisted Intervention (MICCAI) in 2019 and 2020, with a call for algorithms tackling the labelling and segmentation of vertebrae. Two datasets containing a total of 374 multi-detector CT scans from 355 patients were prepared and 4505 vertebrae have individually been annotated at voxel level by a human-machine hybrid algorithm (https://osf.io/nqjyw/, https://osf.io/t98fz/). A total of 25 algorithms were benchmarked on these datasets. In this work, we present the results of this evaluation and further investigate the performance variation at the vertebra level, scan level, and different fields of view. We also evaluate the generalisability of the approaches to an implicit domain shift in data by evaluating the top-performing algorithms of one challenge iteration on data from the other iteration. The principal takeaway from VerSe: the performance of an algorithm in labelling and segmenting a spine scan hinges on its ability to correctly identify vertebrae in cases of rare anatomical variations. The VerSe content and code can be accessed at: https://github.com/anjany/verse. Y1 - 2021 U6 - https://doi.org/10.1016/j.media.2021.102166 VL - 73 ER - TY - JOUR A1 - Sipiran, Ivan A1 - Lazo, Patrick A1 - Lopez, Cristian A1 - Bagewadi, Nihar A1 - Bustos, Benjamin A1 - Dao, Hieu A1 - Gangisetty, Shankar A1 - Hanik, Martin A1 - Ho-Thi, Ngoc-Phuong A1 - Holenderski, Mike A1 - Jarnikov, Dmitri A1 - Labrada, Arniel A1 - Lengauer, Stefan A1 - Licandro, Roxane A1 - Nguyen, Dinh-Huan A1 - Nguyen-Ho, Thang-Long A1 - Pérez Rey, Luis A. A1 - Pham, Bang-Dang A1 - Pham, Minh-Khoi A1 - Preiner, Reinhold A1 - Schreck, Tobias A1 - Trinh, Quoc-Huy A1 - Tonnaer, Loek A1 - von Tycowicz, Christoph A1 - Vu-Le, The-Anh T1 - SHREC 2021: Retrieval of Cultural Heritage Objects JF - Computers and Graphics N2 - This paper presents the methods and results of the SHREC’21 contest on a dataset of cultural heritage (CH) objects. We present a dataset of 938 scanned models that have varied geometry and artistic styles. For the competition, we propose two challenges: the retrieval-by-shape challenge and the retrieval-by-culture challenge. The former aims at evaluating the ability of retrieval methods to discriminate cultural heritage objects by overall shape. The latter focuses on assessing the effectiveness of retrieving objects from the same culture. Both challenges constitute a suitable scenario to evaluate modern shape retrieval methods in a CH domain. Ten groups participated in the contest: thirty runs were submitted for the retrieval-by-shape task, and twenty-six runs were submitted for the retrieval-by-culture challenge. The results show a predominance of learning methods on image-based multi-view representations to characterize 3D objects. Nevertheless, the problem presented in our challenges is far from being solved. We also identify the potential paths for further improvements and give insights into the future directions of research. Y1 - 2021 U6 - https://doi.org/10.1016/j.cag.2021.07.010 VL - 100 SP - 1 EP - 20 ER - TY - JOUR A1 - Moewis, Philippe A1 - Kaiser, René A1 - Trepczynski, Adam A1 - von Tycowicz, Christoph A1 - Krahl, Leonie A1 - Ilg, Ansgar A1 - Holz, Johannes A1 - Duda, Georg T1 - Patient specific resurfacing implant knee surgery in subjects with early osteoarthritis results in medial pivot and lateral femoral rollback during flexion: A retrospective pilot study JF - Knee Surgery, Sports Traumatology, Arthroscopy N2 - Purpose. Metallic resurfacing implants have been developed for the treatment of early, focal, small, condylar and trochlear osteoarthritis (OA) lesions. They represent an option for patients who are either too young to fulfill the criteria for total knee arthroplasty (TKA) or too old for biological treatment. Although relevant clinical evidence has been collected for different resurfacing types, the in vivo post-operative knee kinematics remains unknown. The present study aims to measure and analyse the knee joint kinematics in subjects with patient-specific Episealer implants Methods. Retrospective study design. Fluoroscopic analyses during high flexion activities (unloaded flexion-extension and loaded lunge) were conducted at >12 months post-surgery in ten Episealer knees. The post-operative knee joint kinematics was compared to equally assessed kinematic from ten healthy knees, twenty G-Curve TKA knees and 10 J-Curve knees. Pre- and postoperative clinical data of the Episealer knees were collected using a visual analog scale (VAS), the EQ 5d Health Questionnaire and the Knee Injury and Osteoarthritis Outcome Score (KOOS). Results. During unloaded flexion-extension and loaded lunge, the medial condyle in the Episealer knees remained relative stationary, indicating a medial pivot, while the lateral condyle translated consistently towards posterior. Similarly, reduced movement of the medial condyle and posterior translation of the lateral condyle was also observed in the healthy knees, although to a lesser extent. In contrast, the kinematics of both TKA cohorts during unloaded flexion-extension showed a tendency towards anterior displacement in the medial compartment, which led to significant differences in comparison with the Episealer knees. In the lateral compartment, a certain degree of femoral rollback was noted in the G-Curve TKA cohort. Improved scores were observed in the Episealer subjects between the preoperative and 1-year postoperative follow-up. Conclusion. At 12 months postsurgery, a physiological-like knee kinematics was observed in the group of patient-specific reconstructed chondral/osteochondral lesions by means of a resurfacing Episealer implant strategy. Considering that these patients are physically active and do not fulfill the criteria for TKA, the group is hard to be compared to TKA patients which usually are less active and more challenging. Nevertheless, the comparison to either healthy knee kinematics as well as to TKA reconstructed knees with different implant designs showed a more physiological-like kinematics in the resurfacing implants that seems more appropriate for such a patient group. Despite positive results, careful clinical follow-up of treated patients is recommended for the long-term OA progression. Further investigations need to be encouraged not only in larger patient groups but also in a prospective manner to assess the pre- to postoperative kinematic changes. Y1 - 2021 U6 - https://doi.org/10.1007/s00167-021-06749-8 ER - TY - THES A1 - Punjabi, Dev T1 - Orientation-invariant Dense Correspondence using Graph Convolutional Neural Networks Y1 - 2021 ER - TY - GEN A1 - Ambellan, Felix A1 - Zachow, Stefan A1 - von Tycowicz, Christoph T1 - Geodesic B-Score for Improved Assessment of Knee Osteoarthritis N2 - Three-dimensional medical imaging enables detailed understanding of osteoarthritis structural status. However, there remains a vast need for automatic, thus, reader-independent measures that provide reliable assessment of subject-specific clinical outcomes. To this end, we derive a consistent generalization of the recently proposed B-score to Riemannian shape spaces. We further present an algorithmic treatment yielding simple, yet efficient computations allowing for analysis of large shape populations with several thousand samples. Our intrinsic formulation exhibits improved discrimination ability over its Euclidean counterpart, which we demonstrate for predictive validity on assessing risks of total knee replacement. This result highlights the potential of the geodesic B-score to enable improved personalized assessment and stratification for interventions. T3 - ZIB-Report - 21-09 KW - Statistical shape analysis KW - Osteoarthritis KW - Geometric statistics KW - Riemannian manifolds Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-81930 SN - 1438-0064 ER - TY - JOUR A1 - Weimann, K. A1 - Conrad, Tim T1 - Transfer Learning for ECG Classification JF - Scientific Reports N2 - Remote monitoring devices, which can be worn or implanted, have enabled a more effective healthcare for patients with periodic heart arrhythmia due to their ability to constantly monitor heart activity. However, these devices record considerable amounts of electrocardiogram (ECG) data that needs to be interpreted by physicians. Therefore, there is a growing need to develop reliable methods for automatic ECG interpretation to assist the physicians. Here, we use deep convolutional neural networks (CNN) to classify raw ECG recordings. However, training CNNs for ECG classification often requires a large number of annotated samples, which are expensive to acquire. In this work, we tackle this problem by using transfer learning. First, we pretrain CNNs on the largest public data set of continuous raw ECG signals. Next, we finetune the networks on a small data set for classification of Atrial Fibrillation, which is the most common heart arrhythmia. We show that pretraining improves the performance of CNNs on the target task by up to 6.57%, effectively reducing the number of annotations required to achieve the same performance as CNNs that are not pretrained. We investigate both supervised as well as unsupervised pretraining approaches, which we believe will increase in relevance, since they do not rely on the expensive ECG annotations. The code is available on GitHub at https://github.com/kweimann/ecg-transfer-learning. Y1 - 2021 U6 - https://doi.org/10.1038/s41598-021-84374-8 VL - 11 ER - TY - JOUR A1 - Cvetkovic, Nada A1 - Conrad, Tim A1 - Lie, Han Cheng T1 - A Convergent Discretisation Method for Transition Path Theory for Diffusion Processes JF - Multiscale Modeling & Simulation Y1 - 2021 U6 - https://doi.org/10.1137/20M1329354 VL - 19 IS - 1 SP - 242 EP - 266 PB - Society for Industrial and Applied Mathematics ER - TY - JOUR A1 - Grewe, Carl Martin A1 - Liu, Tuo A1 - Kahl, Christoph A1 - Andrea, Hildebrandt A1 - Zachow, Stefan T1 - Statistical Learning of Facial Expressions Improves Realism of Animated Avatar Faces JF - Frontiers in Virtual Reality Y1 - 2021 U6 - https://doi.org/10.3389/frvir.2021.619811 VL - 2 SP - 1 EP - 13 PB - Frontiers ER - TY - JOUR A1 - Zhang, Wei T1 - Some new results on relative entropy production, time reversal, and optimal control of time-inhomogeneous diffusion processes JF - Journal of Mathematical Physics N2 - This paper studies time-inhomogeneous nonequilibrium diffusion processes, including both Brownian dynamics and Langevin dynamics. We derive upper bounds of the relative entropy production of the time-inhomogeneous process with respect to the transient invariant probability measures. We also study the time reversal of the reverse process in Crooks' fluctuation theorem. We show that the time reversal of the reverse process coincides with the optimally controlled forward process that leads to zero variance importance sampling estimator based on Jarzynski's equality. Y1 - 2021 U6 - https://doi.org/10.1063/5.0038740 VL - 62 IS - 4 ER -