TY - CHAP A1 - Ramm, Heiko A1 - Victoria Morillo, Oscar Salvador A1 - Todt, Ingo A1 - Schirmacher, Hartmut A1 - Ernst, Arneborg A1 - Zachow, Stefan A1 - Lamecker, Hans ED - Freysinger, Wolfgang T1 - Visual Support for Positioning Hearing Implants T2 - Proceedings of the 12th annual meeting of the CURAC society Y1 - 2013 SP - 116 EP - 120 ER - TY - JOUR A1 - Kainmüller, Dagmar A1 - Lamecker, Hans A1 - Heller, Markus O. A1 - Weber, Britta A1 - Hege, Hans-Christian A1 - Zachow, Stefan T1 - Omnidirectional Displacements for Deformable Surfaces JF - Medical Image Analysis Y1 - 2013 U6 - https://doi.org/10.1016/j.media.2012.11.006 VL - 17 IS - 4 SP - 429 EP - 441 PB - Elsevier ER - TY - JOUR A1 - Dunlop, Jason A1 - Apanaskevich, Dmitry A1 - Lehmann, Jens A1 - Hoffmann, Rene A1 - Fusseis, Florian A1 - Ehlke, Moritz A1 - Zachow, Stefan A1 - Xiao, Xianghui T1 - Microtomography of the Baltic amber tick Ixodes succineus reveals affinities with the modern Asian disease vector Ixodes ovatus JF - BMC Evolutionary Biology N2 - Background: Fossil ticks are extremely rare, whereby Ixodes succineus Weidner, 1964 from Eocene (ca. 44-49 Ma) Baltic amber is one of the oldest examples of a living hard tick genus (Ixodida: Ixodidae). Previous work suggested it was most closely related to the modern and widespread European sheep tick Ixodes ricinus (Linneaus, 1758). Results: Restudy using phase contrast synchrotron x-ray tomography yielded images of exceptional quality. These confirm the fossil's referral to Ixodes Latreille, 1795, but the characters resolved here suggest instead affinities with the Asian subgenus Partipalpiger Hoogstraal et al., 1973 and its single living (and medically significant) species Ixodes ovatus Neumann, 1899. We redescribe the amber fossil here as Ixodes (Partipalpiger) succineus. Conclusions: Our data suggest that Ixodes ricinus is unlikely to be directly derived from Weidner's amber species, but instead reveals that the Partipalpiger lineage was originally more widely distributed across the northern hemisphere. The closeness of Ixodes (P.) succineus to a living vector of a wide range of pathogens offers the potential to correlate its spatial and temporal position (northern Europe, nearly 50 million years ago) with the estimated origination dates of various tick-borne diseases. Y1 - 2016 U6 - https://doi.org/10.1186/s12862-016-0777-y VL - 16 IS - 1 ER - TY - JOUR A1 - Schenkl, Sebastian A1 - Muggenthaler, Holger A1 - Hubig, Michael A1 - Erdmann, Bodo A1 - Weiser, Martin A1 - Zachow, Stefan A1 - Heinrich, Andreas A1 - Güttler, Felix Victor A1 - Teichgräber, Ulf A1 - Mall, Gita T1 - Automatic CT-based finite element model generation for temperature-based death time estimation: feasibility study and sensitivity analysis JF - International Journal of Legal Medicine N2 - Temperature based death time estimation is based either on simple phenomenological models of corpse cooling or on detailed physical heat transfer models. The latter are much more complex, but allow a higher accuracy of death time estimation as in principle all relevant cooling mechanisms can be taken into account. Here, a complete work flow for finite element based cooling simulation models is presented. The following steps are demonstrated on CT-phantoms: • CT-scan • Segmentation of the CT images for thermodynamically relevant features of individual geometries • Conversion of the segmentation result into a Finite Element (FE) simulation model • Computation of the model cooling curve • Calculation of the cooling time For the first time in FE-based cooling time estimation the steps from the CT image over segmentation to FE model generation are semi-automatically performed. The cooling time calculation results are compared to cooling measurements performed on the phantoms under controlled conditions. In this context, the method is validated using different CTphantoms. Some of the CT phantoms thermodynamic material parameters had to be experimentally determined via independent experiments. Moreover the impact of geometry and material parameter uncertainties on the estimated cooling time is investigated by a sensitivity analysis. KW - temperature based death time estimation KW - finite element method KW - CT segmentation KW - sensitivity analysis Y1 - 2017 U6 - https://doi.org/doi:10.1007/s00414-016-1523-0 VL - 131 IS - 3 SP - 699 EP - 712 ER - TY - CHAP A1 - Joachimsky, Robert A1 - Ambellan, Felix A1 - Zachow, Stefan T1 - Computerassistierte Auswahl und Platzierung von interpositionalen Spacern zur Behandlung früher Gonarthrose T2 - Proceedings of the Jahrestagung der Deutschen Gesellschaft für Computer- und Roboterassistierte Chirurgie (CURAC) N2 - Degenerative Gelenkerkrankungen, wie die Osteoarthrose, sind ein häufiges Krankheitsbild unter älteren Erwachsenen. Hierbei verringert sich u.a. der Gelenkspalt aufgrund degenerierten Knorpels oder geschädigter Menisci. Ein in den Gelenkspalt eingebrachter interpositionaler Spacer soll die mit der Osteoarthrose einhergehende verringerte Gelenkkontaktfläche erhöhen und so der teilweise oder vollständige Gelenkersatz hinausgezögert oder vermieden werden. In dieser Arbeit präsentieren wir eine Planungssoftware für die Auswahl und Positionierung eines interpositionalen Spacers am Patientenmodell. Auf einer MRT-basierten Bildsegmentierung aufbauend erfolgt eine geometrische Rekonstruktion der 3D-Anatomie des Kniegelenks. Anhand dieser wird der Gelenkspalt bestimmt, sowie ein Spacer ausgewählt und algorithmisch vorpositioniert. Die Positionierung des Spacers ist durch den Benutzer jederzeit interaktiv anpassbar. Für jede Positionierung eines Spacers wird ein Fitness-Wert zur Knieanatomie des jeweiligen Patienten berechnet und den Nutzern Rückmeldung hinsichtlich Passgenauigkeit gegeben. Die Software unterstützt somit als Entscheidungshilfe die behandelnden Ärzte bei der patientenspezifischen Spacerauswahl. KW - Osteoarthrose KW - Kniegelenk KW - Medizinische Planung KW - Visualisierung Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-65321 VL - 16 SP - 106 EP - 111 ER - TY - CHAP A1 - Ambellan, Felix A1 - Tack, Alexander A1 - Wilson, Dave A1 - Anglin, Carolyn A1 - Lamecker, Hans A1 - Zachow, Stefan T1 - Evaluating two methods for Geometry Reconstruction from Sparse Surgical Navigation Data T2 - Proceedings of the Jahrestagung der Deutschen Gesellschaft für Computer- und Roboterassistierte Chirurgie (CURAC) N2 - In this study we investigate methods for fitting a Statistical Shape Model (SSM) to intraoperatively acquired point cloud data from a surgical navigation system. We validate the fitted models against the pre-operatively acquired Magnetic Resonance Imaging (MRI) data from the same patients. We consider a cohort of 10 patients who underwent navigated total knee arthroplasty. As part of the surgical protocol the patients’ distal femurs were partially digitized. All patients had an MRI scan two months pre-operatively. The MRI data were manually segmented and the reconstructed bone surfaces used as ground truth against which the fit was compared. Two methods were used to fit the SSM to the data, based on (1) Iterative Closest Points (ICP) and (2) Gaussian Mixture Models (GMM). For both approaches, the difference between model fit and ground truth surface averaged less than 1.7 mm and excellent correspondence with the distal femoral morphology can be demonstrated. KW - Total Knee Arthoplasty KW - Sparse Geometry Reconstruction KW - Statistical Shape Models Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-65339 VL - 16 SP - 24 EP - 30 ER - TY - GEN A1 - Ambellan, Felix A1 - Tack, Alexander A1 - Wilson, Dave A1 - Anglin, Carolyn A1 - Lamecker, Hans A1 - Zachow, Stefan T1 - Evaluating two methods for Geometry Reconstruction from Sparse Surgical Navigation Data N2 - In this study we investigate methods for fitting a Statistical Shape Model (SSM) to intraoperatively acquired point cloud data from a surgical navigation system. We validate the fitted models against the pre-operatively acquired Magnetic Resonance Imaging (MRI) data from the same patients. We consider a cohort of 10 patients who underwent navigated total knee arthroplasty. As part of the surgical protocol the patients’ distal femurs were partially digitized. All patients had an MRI scan two months pre-operatively. The MRI data were manually segmented and the reconstructed bone surfaces used as ground truth against which the fit was compared. Two methods were used to fit the SSM to the data, based on (1) Iterative Closest Points (ICP) and (2) Gaussian Mixture Models (GMM). For both approaches, the difference between model fit and ground truth surface averaged less than 1.7 mm and excellent correspondence with the distal femoral morphology can be demonstrated. T3 - ZIB-Report - 17-71 KW - Knee Arthroplasty KW - Sparse Geometry Reconstruction KW - Statistical Shape Models Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-66052 SN - 1438-0064 ER - TY - CHAP A1 - Grewe, Carl Martin A1 - le Roux, Gabriel A1 - Pilz, Sven-Kristofer A1 - Zachow, Stefan T1 - Spotting the Details: The Various Facets of Facial Expressions T2 - IEEE International Conference on Automatic Face and Gesture Recognition Y1 - 2018 U6 - https://doi.org/10.1109/FG.2018.00049 SP - 286 EP - 293 ER - TY - GEN A1 - Sahu, Manish A1 - Dill, Sabrina A1 - Mukhopadyay, Anirban A1 - Zachow, Stefan T1 - Surgical Tool Presence Detection for Cataract Procedures N2 - This article outlines the submission to the CATARACTS challenge for automatic tool presence detection [1]. Our approach for this multi-label classification problem comprises labelset-based sampling, a CNN architecture and temporal smothing as described in [3], which we call ZIB-Res-TS. T3 - ZIB-Report - 18-28 Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-69110 SN - 1438-0064 ER - TY - JOUR A1 - Tack, Alexander A1 - Mukhopadhyay, Anirban A1 - Zachow, Stefan T1 - Knee Menisci Segmentation using Convolutional Neural Networks: Data from the Osteoarthritis Initiative JF - Osteoarthritis and Cartilage N2 - Abstract: Objective: To present a novel method for automated segmentation of knee menisci from MRIs. To evaluate quantitative meniscal biomarkers for osteoarthritis (OA) estimated thereof. Method: A segmentation method employing convolutional neural networks in combination with statistical shape models was developed. Accuracy was evaluated on 88 manual segmentations. Meniscal volume, tibial coverage, and meniscal extrusion were computed and tested for differences between groups of OA, joint space narrowing (JSN), and WOMAC pain. Correlation between computed meniscal extrusion and MOAKS experts' readings was evaluated for 600 subjects. Suitability of biomarkers for predicting incident radiographic OA from baseline to 24 months was tested on a group of 552 patients (184 incident OA, 386 controls) by performing conditional logistic regression. Results: Segmentation accuracy measured as Dice Similarity Coefficient was 83.8% for medial menisci (MM) and 88.9% for lateral menisci (LM) at baseline, and 83.1% and 88.3% at 12-month follow-up. Medial tibial coverage was significantly lower for arthritic cases compared to non-arthritic ones. Medial meniscal extrusion was significantly higher for arthritic knees. A moderate correlation between automatically computed medial meniscal extrusion and experts' readings was found (ρ=0.44). Mean medial meniscal extrusion was significantly greater for incident OA cases compared to controls (1.16±0.93 mm vs. 0.83±0.92 mm; p<0.05). Conclusion: Especially for medial menisci an excellent segmentation accuracy was achieved. Our meniscal biomarkers were validated by comparison to experts' readings as well as analysis of differences w.r.t groups of OA, JSN, and WOMAC pain. It was confirmed that medial meniscal extrusion is a predictor for incident OA. Y1 - 2018 U6 - https://doi.org/10.1016/j.joca.2018.02.907 VL - 26 IS - 5 SP - 680 EP - 688 ER - TY - GEN A1 - Tack, Alexander A1 - Mukhopadhyay, Anirban A1 - Zachow, Stefan T1 - Knee Menisci Segmentation using Convolutional Neural Networks: Data from the Osteoarthritis Initiative (Supplementary Material) N2 - Abstract: Objective: To present a novel method for automated segmentation of knee menisci from MRIs. To evaluate quantitative meniscal biomarkers for osteoarthritis (OA) estimated thereof. Method: A segmentation method employing convolutional neural networks in combination with statistical shape models was developed. Accuracy was evaluated on 88 manual segmentations. Meniscal volume, tibial coverage, and meniscal extrusion were computed and tested for differences between groups of OA, joint space narrowing (JSN), and WOMAC pain. Correlation between computed meniscal extrusion and MOAKS experts' readings was evaluated for 600 subjects. Suitability of biomarkers for predicting incident radiographic OA from baseline to 24 months was tested on a group of 552 patients (184 incident OA, 386 controls) by performing conditional logistic regression. Results: Segmentation accuracy measured as Dice Similarity Coefficient was 83.8% for medial menisci (MM) and 88.9% for lateral menisci (LM) at baseline, and 83.1% and 88.3% at 12-month follow-up. Medial tibial coverage was significantly lower for arthritic cases compared to non-arthritic ones. Medial meniscal extrusion was significantly higher for arthritic knees. A moderate correlation between automatically computed medial meniscal extrusion and experts' readings was found (ρ=0.44). Mean medial meniscal extrusion was significantly greater for incident OA cases compared to controls (1.16±0.93 mm vs. 0.83±0.92 mm; p<0.05). Conclusion: Especially for medial menisci an excellent segmentation accuracy was achieved. Our meniscal biomarkers were validated by comparison to experts' readings as well as analysis of differences w.r.t groups of OA, JSN, and WOMAC pain. It was confirmed that medial meniscal extrusion is a predictor for incident OA. Y1 - 2018 U6 - https://doi.org/10.12752/4.TMZ.1.0 N1 - Supplementary data to reproduce results from the related publication, including convolutional neural networks' weights. ER - TY - CHAP A1 - Krämer, Martin A1 - Maggioni, Marta A1 - Tycowicz, Christoph von A1 - Brisson, Nick A1 - Zachow, Stefan A1 - Duda, Georg A1 - Reichenbach, Jürgen T1 - Ultra-short echo-time (UTE) imaging of the knee with curved surface reconstruction-based extraction of the patellar tendon T2 - ISMRM (International Society for Magnetic Resonance in Medicine), 26th Annual Meeting 2018, Paris, France N2 - Due to very short T2 relaxation times, imaging of tendons is typically performed using ultra-short echo-time (UTE) acquisition techniques. In this work, we combined an echo-train shifted multi-echo 3D UTE imaging sequence with a 3D curved surface reconstruction to virtually extract the patellar tendon from an acquired 3D UTE dataset. Based on the analysis of the acquired multi-echo data, a T2* relaxation time parameter map was calculated and interpolated to the curved surface of the patellar tendon. Y1 - 2018 ER - TY - CHAP A1 - Ambellan, Felix A1 - Tack, Alexander A1 - Ehlke, Moritz A1 - Zachow, Stefan T1 - Automated Segmentation of Knee Bone and Cartilage combining Statistical Shape Knowledge and Convolutional Neural Networks: Data from the Osteoarthritis Initiative T2 - Medical Imaging with Deep Learning N2 - We present a method for the automated segmentation of knee bones and cartilage from magnetic resonance imaging, that combines a priori knowledge of anatomical shape with Convolutional Neural Networks (CNNs). The proposed approach incorporates 3D Statistical Shape Models (SSMs) as well as 2D and 3D CNNs to achieve a robust and accurate segmentation of even highly pathological knee structures. The method is evaluated on data of the MICCAI grand challenge "Segmentation of Knee Images 2010". For the first time an accuracy equivalent to the inter-observer variability of human readers has been achieved in this challenge. Moreover, the quality of the proposed method is thoroughly assessed using various measures for 507 manual segmentations of bone and cartilage, and 88 additional manual segmentations of cartilage. Our method yields sub-voxel accuracy. In conclusion, combining of anatomical knowledge using SSMs with localized classification via CNNs results in a state-of-the-art segmentation method. Y1 - 2018 ER - TY - JOUR A1 - Brüning, Jan A1 - Hildebrandt, Thomas A1 - Heppt, Werner A1 - Schmidt, Nora A1 - Lamecker, Hans A1 - Szengel, Angelika A1 - Amiridze, Natalja A1 - Ramm, Heiko A1 - Bindernagel, Matthias A1 - Zachow, Stefan A1 - Goubergrits, Leonid T1 - Characterization of the Airflow within an Average Geometry of the Healthy Human Nasal Cavity JF - Scientific Reports N2 - This study’s objective was the generation of a standardized geometry of the healthy nasal cavity. An average geometry of the healthy nasal cavity was generated using a statistical shape model based on 25 symptom-free subjects. Airflow within the average geometry and these geometries was calculated using fluid simulations. Integral measures of the nasal resistance, wall shear stresses (WSS) and velocities were calculated as well as cross-sectional areas (CSA). Furthermore, individual WSS and static pressure distributions were mapped onto the average geometry. The average geometry featured an overall more regular shape that resulted in less resistance, reduced wall shear stresses and velocities compared to the median of the 25 geometries. Spatial distributions of WSS and pressure of average geometry agreed well compared to the average distributions of all individual geometries. The minimal CSA of the average geometry was larger than the median of all individual geometries (83.4 vs. 74.7 mm²). The airflow observed within the average geometry of the healthy nasal cavity did not equal the average airflow of the individual geometries. While differences observed for integral measures were notable, the calculated values for the average geometry lay within the distributions of the individual parameters. Spatially resolved parameters differed less prominently. Y1 - 2020 UR - https://rdcu.be/b2irD U6 - https://doi.org/10.1038/s41598-020-60755-3 VL - 3755 IS - 10 ER - TY - CHAP A1 - Sahu, Manish A1 - Strömsdörfer, Ronja A1 - Mukhopadhyay, Anirban A1 - Zachow, Stefan T1 - Endo-Sim2Real: Consistency learning-based domain adaptation for instrument segmentation T2 - Proc. Medical Image Computing and Computer Assisted Intervention (MICCAI), Part III N2 - Surgical tool segmentation in endoscopic videos is an important component of computer assisted interventions systems. Recent success of image-based solutions using fully-supervised deep learning approaches can be attributed to the collection of big labeled datasets. However, the annotation of a big dataset of real videos can be prohibitively expensive and time consuming. Computer simulations could alleviate the manual labeling problem, however, models trained on simulated data do not generalize to real data. This work proposes a consistency-based framework for joint learning of simulated and real (unlabeled) endoscopic data to bridge this performance generalization issue. Empirical results on two data sets (15 videos of the Cholec80 and EndoVis'15 dataset) highlight the effectiveness of the proposed Endo-Sim2Real method for instrument segmentation. We compare the segmentation of the proposed approach with state-of-the-art solutions and show that our method improves segmentation both in terms of quality and quantity. Y1 - 2020 U6 - https://doi.org/https://doi.org/10.1007/978-3-030-59716-0_75 VL - 12263 PB - Springer Nature ER - TY - JOUR A1 - Sahu, Manish A1 - Szengel, Angelika A1 - Mukhopadhyay, Anirban A1 - Zachow, Stefan T1 - Surgical phase recognition by learning phase transitions JF - Current Directions in Biomedical Engineering (CDBME) N2 - Automatic recognition of surgical phases is an important component for developing an intra-operative context-aware system. Prior work in this area focuses on recognizing short-term tool usage patterns within surgical phases. However, the difference between intra- and inter-phase tool usage patterns has not been investigated for automatic phase recognition. We developed a Recurrent Neural Network (RNN), in particular a state-preserving Long Short Term Memory (LSTM) architecture to utilize the long-term evolution of tool usage within complete surgical procedures. For fully automatic tool presence detection from surgical video frames, a Convolutional Neural Network (CNN) based architecture namely ZIBNet is employed. Our proposed approach outperformed EndoNet by 8.1% on overall precision for phase detection tasks and 12.5% on meanAP for tool recognition tasks. Y1 - 2020 U6 - https://doi.org/https://doi.org/10.1515/cdbme-2020-0037 N1 - Nomination for the Best-Paper Award VL - 6 IS - 1 SP - 20200037 PB - De Gruyter ER - TY - GEN A1 - Sahu, Manish A1 - Szengel, Angelika A1 - Mukhopadhyay, Anirban A1 - Zachow, Stefan T1 - Analyzing laparoscopic cholecystectomy with deep learning: automatic detection of surgical tools and phases T2 - 28th International Congress of the European Association for Endoscopic Surgery (EAES) N2 - Motivation: The ever-rising volume of patients, high maintenance cost of operating rooms and time consuming analysis of surgical skills are fundamental problems that hamper the practical training of the next generation of surgeons. The hospitals prefer to keep the surgeons busy in real operations over training young surgeons for obvious economic reasons. One fundamental need in surgical training is the reduction of the time needed by the senior surgeon to review the endoscopic procedures performed by the young surgeon while minimizing the subjective bias in evaluation. The unprecedented performance of deep learning ushers the new age of data-driven automatic analysis of surgical skills. Method: Deep learning is capable of efficiently analyzing thousands of hours of laparoscopic video footage to provide an objective assessment of surgical skills. However, the traditional end-to-end setting of deep learning (video in, skill assessment out) is not explainable. Our strategy is to utilize the surgical process modeling framework to divide the surgical process into understandable components. This provides the opportunity to employ deep learning for superior yet automatic detection and evaluation of several aspects of laparoscopic cholecystectomy such as surgical tool and phase detection. We employ ZIBNet for the detection of surgical tool presence. ZIBNet employs pre-processing based on tool usage imbalance, a transfer learned 50-layer residual network (ResNet-50) and temporal smoothing. To encode the temporal evolution of tool usage (over the entire video sequence) that relates to the surgical phases, Long Short Term Memory (LSTM) units are employed with long-term dependency. Dataset: We used CHOLEC 80 dataset that consists of 80 videos of laparoscopic cholecystectomy performed by 13 surgeons, divided equally for training and testing. In these videos, up to three different tools (among 7 types of tools) can be present in a frame. Results: The mean average precision of the detection of all tools is 93.5 ranging between 86.8 and 99.3, a significant improvement (p <0.01) over the previous state-of-the-art. We observed that less frequent tools like Scissors, Irrigator, Specimen Bag etc. are more related to phase transitions. The overall precision (recall) of the detection of all surgical phases is 79.6 (81.3). Conclusion: While this is not the end goal for surgical skill analysis, the development of such a technological platform is essential toward a data-driven objective understanding of surgical skills. In future, we plan to investigate surgeon-in-the-loop analysis and feedback for surgical skill analysis. Y1 - 2020 UR - https://academy.eaes.eu/eaes/2020/28th/298882/manish.sahu.analyzing.laparoscopic.cholecystectomy.with.deep.learning.html?f=listing%3D0%2Abrowseby%3D8%2Asortby%3D2 ER - TY - JOUR A1 - Pimentel, Pedro A1 - Szengel, Angelika A1 - Ehlke, Moritz A1 - Lamecker, Hans A1 - Zachow, Stefan A1 - Estacio, Laura A1 - Doenitz, Christian A1 - Ramm, Heiko ED - Li, Jianning ED - Egger, Jan T1 - Automated Virtual Reconstruction of Large Skull Defects using Statistical Shape Models and Generative Adversarial Networks BT - First Challenge, AutoImplant 2020, Held in Conjunction with MICCAI 2020, Lima, Peru, October 8, 2020, Proceedings JF - Towards the Automatization of Cranial Implant Design in Cranioplasty N2 - We present an automated method for extrapolating missing regions in label data of the skull in an anatomically plausible manner. The ultimate goal is to design patient-speci� c cranial implants for correcting large, arbitrarily shaped defects of the skull that can, for example, result from trauma of the head. Our approach utilizes a 3D statistical shape model (SSM) of the skull and a 2D generative adversarial network (GAN) that is trained in an unsupervised fashion from samples of healthy patients alone. By � tting the SSM to given input labels containing the skull defect, a First approximation of the healthy state of the patient is obtained. The GAN is then applied to further correct and smooth the output of the SSM in an anatomically plausible manner. Finally, the defect region is extracted using morphological operations and subtraction between the extrapolated healthy state of the patient and the defective input labels. The method is trained and evaluated based on data from the MICCAI 2020 AutoImplant challenge. It produces state-of-the art results on regularly shaped cut-outs that were present in the training and testing data of the challenge. Furthermore, due to unsupervised nature of the approach, the method generalizes well to previously unseen defects of varying shapes that were only present in the hidden test dataset. Y1 - 2020 U6 - https://doi.org/10.1007/978-3-030-64327-0_3 N1 - Best Paper Award VL - 12439 SP - 16 EP - 27 PB - Springer International Publishing ET - 1 ER - TY - GEN A1 - Grewe, Carl Martin A1 - Zachow, Stefan ED - Doll, Nikola ED - Bredekamp, Horst ED - Schäffner, Wolfgang T1 - Face to Face-Interface T2 - +ultra. Knowledge & Gestaltung Y1 - 2017 SP - 320 EP - 321 PB - Seemann Henschel ER - TY - GEN A1 - Grewe, Carl Martin A1 - Le Roux, Gabriel A1 - Pilz, Sven-Kristofer A1 - Zachow, Stefan T1 - Spotting the Details: The Various Facets of Facial Expressions N2 - 3D Morphable Models (MM) are a popular tool for analysis and synthesis of facial expressions. They represent plausible variations in facial shape and appearance within a low-dimensional parameter space. Fitted to a face scan, the model's parameters compactly encode its expression patterns. This expression code can be used, for instance, as a feature in automatic facial expression recognition. For accurate classification, an MM that can adequately represent the various characteristic facets and variants of each expression is necessary. Currently available MMs are limited in the diversity of expression patterns. We present a novel high-quality Facial Expression Morphable Model built from a large-scale face database as a tool for expression analysis and synthesis. Establishment of accurate dense correspondence, up to finest skin features, enables a detailed statistical analysis of facial expressions. Various characteristic shape patterns are identified for each expression. The results of our analysis give rise to a new facial expression code. We demonstrate the advantages of such a code for the automatic recognition of expressions, and compare the accuracy of our classifier to state-of-the-art. T3 - ZIB-Report - 18-06 Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-67696 SN - 1438-0064 ER -