TY - JOUR A1 - Sahu, Manish A1 - Mukhopadhyay, Anirban A1 - Szengel, Angelika A1 - Zachow, Stefan T1 - Addressing multi-label imbalance problem of Surgical Tool Detection using CNN JF - International Journal of Computer Assisted Radiology and Surgery N2 - Purpose: A fully automated surgical tool detection framework is proposed for endoscopic video streams. State-of-the-art surgical tool detection methods rely on supervised one-vs-all or multi-class classification techniques, completely ignoring the co-occurrence relationship of the tools and the associated class imbalance. Methods: In this paper, we formulate tool detection as a multi-label classification task where tool co-occurrences are treated as separate classes. In addition, imbalance on tool co-occurrences is analyzed and stratification techniques are employed to address the imbalance during Convolutional Neural Network (CNN) training. Moreover, temporal smoothing is introduced as an online post-processing step to enhance run time prediction. Results: Quantitative analysis is performed on the M2CAI16 tool detection dataset to highlight the importance of stratification, temporal smoothing and the overall framework for tool detection. Conclusion: The analysis on tool imbalance, backed by the empirical results indicates the need and superiority of the proposed framework over state-of-the-art techniques. Y1 - 2017 UR - https://link.springer.com/article/10.1007/s11548-017-1565-x U6 - https://doi.org/10.1007/s11548-017-1565-x N1 - Selected for final oral presentation VL - 12 IS - 6 SP - 1013 EP - 1020 PB - Springer ER - TY - JOUR A1 - Schenkl, Sebastian A1 - Muggenthaler, Holger A1 - Hubig, Michael A1 - Erdmann, Bodo A1 - Weiser, Martin A1 - Zachow, Stefan A1 - Heinrich, Andreas A1 - Güttler, Felix Victor A1 - Teichgräber, Ulf A1 - Mall, Gita T1 - Automatic CT-based finite element model generation for temperature-based death time estimation: feasibility study and sensitivity analysis JF - International Journal of Legal Medicine N2 - Temperature based death time estimation is based either on simple phenomenological models of corpse cooling or on detailed physical heat transfer models. The latter are much more complex, but allow a higher accuracy of death time estimation as in principle all relevant cooling mechanisms can be taken into account. Here, a complete work flow for finite element based cooling simulation models is presented. The following steps are demonstrated on CT-phantoms: • CT-scan • Segmentation of the CT images for thermodynamically relevant features of individual geometries • Conversion of the segmentation result into a Finite Element (FE) simulation model • Computation of the model cooling curve • Calculation of the cooling time For the first time in FE-based cooling time estimation the steps from the CT image over segmentation to FE model generation are semi-automatically performed. The cooling time calculation results are compared to cooling measurements performed on the phantoms under controlled conditions. In this context, the method is validated using different CTphantoms. Some of the CT phantoms thermodynamic material parameters had to be experimentally determined via independent experiments. Moreover the impact of geometry and material parameter uncertainties on the estimated cooling time is investigated by a sensitivity analysis. KW - temperature based death time estimation KW - finite element method KW - CT segmentation KW - sensitivity analysis Y1 - 2017 U6 - https://doi.org/doi:10.1007/s00414-016-1523-0 VL - 131 IS - 3 SP - 699 EP - 712 ER - TY - GEN A1 - Sahu, Manish A1 - Dill, Sabrina A1 - Mukhopadyay, Anirban A1 - Zachow, Stefan T1 - Surgical Tool Presence Detection for Cataract Procedures N2 - This article outlines the submission to the CATARACTS challenge for automatic tool presence detection [1]. Our approach for this multi-label classification problem comprises labelset-based sampling, a CNN architecture and temporal smothing as described in [3], which we call ZIB-Res-TS. T3 - ZIB-Report - 18-28 Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-69110 SN - 1438-0064 ER - TY - JOUR A1 - Wilson, David A1 - Anglin, Carolyn A1 - Ambellan, Felix A1 - Grewe, Carl Martin A1 - Tack, Alexander A1 - Lamecker, Hans A1 - Dunbar, Michael A1 - Zachow, Stefan T1 - Validation of three-dimensional models of the distal femur created from surgical navigation point cloud data for intraoperative and postoperative analysis of total knee arthroplasty JF - International Journal of Computer Assisted Radiology and Surgery N2 - Purpose: Despite the success of total knee arthroplasty there continues to be a significant proportion of patients who are dissatisfied. One explanation may be a shape mismatch between pre and post-operative distal femurs. The purpose of this study was to investigate a method to match a statistical shape model (SSM) to intra-operatively acquired point cloud data from a surgical navigation system, and to validate it against the pre-operative magnetic resonance imaging (MRI) data from the same patients. Methods: A total of 10 patients who underwent navigated total knee arthroplasty also had an MRI scan less than 2 months pre-operatively. The standard surgical protocol was followed which included partial digitization of the distal femur. Two different methods were employed to fit the SSM to the digitized point cloud data, based on (1) Iterative Closest Points (ICP) and (2) Gaussian Mixture Models (GMM). The available MRI data were manually segmented and the reconstructed three-dimensional surfaces used as ground truth against which the statistical shape model fit was compared. Results: For both approaches, the difference between the statistical shape model-generated femur and the surface generated from MRI segmentation averaged less than 1.7 mm, with maximum errors occurring in less clinically important areas. Conclusion: The results demonstrated good correspondence with the distal femoral morphology even in cases of sparse data sets. Application of this technique will allow for measurement of mismatch between pre and post-operative femurs retrospectively on any case done using the surgical navigation system and could be integrated into the surgical navigation unit to provide real-time feedback. Y1 - 2017 UR - https://link.springer.com/content/pdf/10.1007%2Fs11548-017-1630-5.pdf U6 - https://doi.org/10.1007/s11548-017-1630-5 VL - 12 IS - 12 SP - 2097 EP - 2105 PB - Springer ER - TY - GEN A1 - Grewe, Carl Martin A1 - Zachow, Stefan ED - Doll, Nikola ED - Bredekamp, Horst ED - Schäffner, Wolfgang T1 - Face to Face-Interface T2 - +ultra. Knowledge & Gestaltung Y1 - 2017 SP - 320 EP - 321 PB - Seemann Henschel ER - TY - JOUR A1 - Zahn, Robert A1 - Grotjohann, Sarah A1 - Ramm, Heiko A1 - Zachow, Stefan A1 - Pumberger, Matthias A1 - Putzier, Michael A1 - Perka, Carsten A1 - Tohtz, Stephan T1 - Influence of pelvic tilt on functional acetabular orientation JF - Technology and Health Care Y1 - 2016 U6 - https://doi.org/10.3233/THC-161281 VL - 25 IS - 3 SP - 557 EP - 565 PB - IOS Press ER - TY - JOUR A1 - Lemanis, Robert A1 - Korn, Dieter A1 - Zachow, Stefan A1 - Rybacki, Erik A1 - Hoffmann, René T1 - The Evolution and Development of Cephalopod Chambers and Their Shape JF - PLOS ONE N2 - The Ammonoidea is a group of extinct cephalopods ideal to study evolution through deep time. The evolution of the planispiral shell and complexly folded septa in ammonoids has been thought to have increased the functional surface area of the chambers permitting enhanced metabolic functions such as: chamber emptying, rate of mineralization and increased growth rates throughout ontogeny. Using nano-computed tomography and synchrotron radiation based micro-computed tomography, we present the first study of ontogenetic changes in surface area to volume ratios in the phragmocone chambers of several phylogenetically distant ammonoids and extant cephalopods. Contrary to the initial hypothesis, ammonoids do not possess a persistently high relative chamber surface area. Instead, the functional surface area of the chambers is higher in earliest ontogeny when compared to Spirula spirula. The higher the functional surface area the quicker the potential emptying rate of the chamber; quicker chamber emptying rates would theoretically permit faster growth. This is supported by the persistently higher siphuncular surface area to chamber volume ratio we collected for the ammonite Amauroceras sp. compared to either S. spirula or nautilids. We demonstrate that the curvature of the surface of the chamber increases with greater septal complexity increasing the potential refilling rates. We further show a unique relationship between ammonoid chamber shape and size that does not exist in S. spirula or nautilids. This view of chamber function also has implications for the evolution of the internal shell of coleoids, relating this event to the decoupling of soft-body growth and shell growth. Y1 - 2016 U6 - https://doi.org/10.1371/journal.pone.0151404 VL - 11 IS - 3 ER - TY - JOUR A1 - Dunlop, Jason A1 - Apanaskevich, Dmitry A1 - Lehmann, Jens A1 - Hoffmann, Rene A1 - Fusseis, Florian A1 - Ehlke, Moritz A1 - Zachow, Stefan A1 - Xiao, Xianghui T1 - Microtomography of the Baltic amber tick Ixodes succineus reveals affinities with the modern Asian disease vector Ixodes ovatus JF - BMC Evolutionary Biology N2 - Background: Fossil ticks are extremely rare, whereby Ixodes succineus Weidner, 1964 from Eocene (ca. 44-49 Ma) Baltic amber is one of the oldest examples of a living hard tick genus (Ixodida: Ixodidae). Previous work suggested it was most closely related to the modern and widespread European sheep tick Ixodes ricinus (Linneaus, 1758). Results: Restudy using phase contrast synchrotron x-ray tomography yielded images of exceptional quality. These confirm the fossil's referral to Ixodes Latreille, 1795, but the characters resolved here suggest instead affinities with the Asian subgenus Partipalpiger Hoogstraal et al., 1973 and its single living (and medically significant) species Ixodes ovatus Neumann, 1899. We redescribe the amber fossil here as Ixodes (Partipalpiger) succineus. Conclusions: Our data suggest that Ixodes ricinus is unlikely to be directly derived from Weidner's amber species, but instead reveals that the Partipalpiger lineage was originally more widely distributed across the northern hemisphere. The closeness of Ixodes (P.) succineus to a living vector of a wide range of pathogens offers the potential to correlate its spatial and temporal position (northern Europe, nearly 50 million years ago) with the estimated origination dates of various tick-borne diseases. Y1 - 2016 U6 - https://doi.org/10.1186/s12862-016-0777-y VL - 16 IS - 1 ER - TY - JOUR A1 - Bernard, Florian A1 - Salamanca, Luis A1 - Thunberg, Johan A1 - Tack, Alexander A1 - Jentsch, Dennis A1 - Lamecker, Hans A1 - Zachow, Stefan A1 - Hertel, Frank A1 - Goncalves, Jorge A1 - Gemmar, Peter T1 - Shape-aware Surface Reconstruction from Sparse Data JF - arXiv N2 - The reconstruction of an object's shape or surface from a set of 3D points is a common topic in materials and life sciences, computationally handled in computer graphics. Such points usually stem from optical or tactile 3D coordinate measuring equipment. Surface reconstruction also appears in medical image analysis, e.g. in anatomy reconstruction from tomographic measurements or the alignment of intra-operative navigation and preoperative planning data. In contrast to mere 3D point clouds, medical imaging yields contextual information on the 3D point data that can be used to adopt prior information on the shape that is to be reconstructed from the measurements. In this work we propose to use a statistical shape model (SSM) as a prior for surface reconstruction. The prior knowledge is represented by a point distribution model (PDM) that is associated with a surface mesh. Using the shape distribution that is modelled by the PDM, we reformulate the problem of surface reconstruction from a probabilistic perspective based on a Gaussian Mixture Model (GMM). In order to do so, the given measurements are interpreted as samples of the GMM. By using mixture components with anisotropic covariances that are oriented according to the surface normals at the PDM points, a surface-based tting is accomplished. By estimating the parameters of the GMM in a maximum a posteriori manner, the reconstruction of the surface from the given measurements is achieved. Extensive experiments suggest that our proposed approach leads to superior surface reconstructions compared to Iterative Closest Point (ICP) methods. Y1 - 2016 SP - 1602.08425v1 ER - TY - JOUR A1 - Lemanis, Robert A1 - Zachow, Stefan A1 - Hoffmann, René T1 - Comparative cephalopod shell strength and the role of septum morphology on stress distribution JF - PeerJ N2 - The evolution of complexly folded septa in ammonoids has long been a controversial topic. Explanations of the function of these folded septa can be divided into physiological and mechanical hypotheses with the mechanical functions tending to find widespread support. The complexity of the cephalopod shell has made it difficult to directly test the mechanical properties of these structures without oversimplification of the septal morphology or extraction of a small sub-domain. However, the power of modern finite element analysis now permits direct testing of mechanical hypothesis on complete, empirical models of the shells taken from computed tomographic data. Here we compare, for the first time using empirical models, the capability of the shells of extant Nautilus pompilius, Spirula spirula, and the extinct ammonite Cadoceras sp. to withstand hydrostatic pressure and point loads. Results show hydrostatic pressure imparts highest stress on the final septum with the rest of the shell showing minimal compression. S. spirula shows the lowest stress under hydrostatic pressure while N. pompilius shows the highest stress. Cadoceras sp. shows the development of high stress along the attachment of the septal saddles with the shell wall. Stress due to point loads decreases when the point force is directed along the suture as opposed to the unsupported chamber wall. Cadoceras sp. shows the greatest decrease in stress between the point loads compared to all other models. Greater amplitude of septal flutes corresponds with greater stress due to hydrostatic pressure; however, greater amplitude decreases the stress magnitude of point loads directed along the suture. In our models, sutural complexity does not predict greater resistance to hydrostatic pressure but it does seem to increase resistance to point loads, such as would be from predators. This result permits discussion of palaeoecological reconstructions on the basis of septal morphology. We further suggest that the ratio used to characterize septal morphology in the septal strength index and in calculations of tensile strength of nacre are likely insufficient. A better understanding of the material properties of cephalopod nacre may allow the estimation of maximum depth limits of shelled cephalopods through finite element analysis. Y1 - 2016 U6 - https://doi.org/10.7717/peerj.2434 VL - 4 SP - e2434 ER - TY - CHAP A1 - Mukhopadhyay, Anirban A1 - Morillo, Oscar A1 - Zachow, Stefan A1 - Lamecker, Hans T1 - Robust and Accurate Appearance Models Based on Joint Dictionary Learning Data from the Osteoarthritis Initiative T2 - Lecture Notes in Computer Science, Patch-Based Techniques in Medical Imaging. Patch-MI 2016 N2 - Deformable model-based approaches to 3D image segmentation have been shown to be highly successful. Such methodology requires an appearance model that drives the deformation of a geometric model to the image data. Appearance models are usually either created heuristically or through supervised learning. Heuristic methods have been shown to work effectively in many applications but are hard to transfer from one application (imaging modality/anatomical structure) to another. On the contrary, supervised learning approaches can learn patterns from a collection of annotated training data. In this work, we show that the supervised joint dictionary learning technique is capable of overcoming the traditional drawbacks of the heuristic approaches. Our evaluation based on two different applications (liver/CT and knee/MR) reveals that our approach generates appearance models, which can be used effectively and efficiently in a deformable model-based segmentation framework. Y1 - 2016 U6 - https://doi.org/10.1007/978-3-319-47118-1_4 VL - 9993 SP - 25 EP - 33 ER - TY - CHAP A1 - Lamecker, Hans A1 - Zachow, Stefan T1 - Statistical Shape Modeling of Musculoskeletal Structures and Its Applications T2 - Computational Radiology for Orthopaedic Interventions N2 - Statistical shape models (SSM) describe the shape variability contained in a given population. They are able to describe large populations of complex shapes with few degrees of freedom. This makes them a useful tool for a variety of tasks that arise in computer-aided madicine. In this chapter we are going to explain the basic methodology of SSMs and present a variety of examples, where SSMs have been successfully applied. Y1 - 2016 SN - 978-3-319-23481-6 U6 - https://doi.org/10.1007/978-3-319-23482-3 VL - 23 SP - 1 EP - 23 PB - Springer ER - TY - GEN A1 - Tycowicz, Christoph von A1 - Ambellan, Felix A1 - Mukhopadhyay, Anirban A1 - Zachow, Stefan T1 - A Riemannian Statistical Shape Model using Differential Coordinates N2 - We propose a novel Riemannian framework for statistical analysis of shapes that is able to account for the nonlinearity in shape variation. By adopting a physical perspective, we introduce a differential representation that puts the local geometric variability into focus. We model these differential coordinates as elements of a Lie group thereby endowing our shape space with a non-Euclidian structure. A key advantage of our framework is that statistics in a manifold shape space become numerically tractable improving performance by several orders of magnitude over state-of-the-art. We show that our Riemannian model is well suited for the identification of intra-population variability as well as inter-population differences. In particular, we demonstrate the superiority of the proposed model in experiments on specificity and generalization ability. We further derive a statistical shape descriptor that outperforms the standard Euclidian approach in terms of shape-based classification of morphological disorders. T3 - ZIB-Report - 16-69 Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-61175 UR - https://opus4.kobv.de/opus4-zib/frontdoor/index/index/docId/6485 SN - 1438-0064 ER - TY - CHAP A1 - Grewe, Carl Martin A1 - Zachow, Stefan T1 - Fully Automated and Highly Accurate Dense Correspondence for Facial Surfaces T2 - Computer Vision – ECCV 2016 Workshops N2 - We present a novel framework for fully automated and highly accurate determination of facial landmarks and dense correspondence, e.g. a topologically identical mesh of arbitrary resolution, across the entire surface of 3D face models. For robustness and reliability of the proposed approach, we are combining 2D landmark detectors and 3D statistical shape priors with a variational matching method. Instead of matching faces in the spatial domain only, we employ image registration to align the 2D parametrization of the facial surface to a planar template we call the Unified Facial Parameter Domain (ufpd). This allows us to simultaneously match salient photometric and geometric facial features using robust image similarity measures while reasonably constraining geometric distortion in regions with less significant features. We demonstrate the accuracy of the dense correspondence established by our framework on the BU3DFE database with 2500 facial surfaces and show, that our framework outperforms current state-of-the-art methods with respect to the fully automated location of facial landmarks. Y1 - 2016 U6 - https://doi.org/10.1007/978-3-319-48881-3_38 VL - 9914 SP - 552 EP - 568 PB - Springer International Publishing ER - TY - JOUR A1 - Zachow, Stefan T1 - Computational Planning in Facial Surgery JF - Facial Plastic Surgery N2 - This article reflects the research of the last two decades in computational planning for cranio-maxillofacial surgery. Model-guided and computer-assisted surgery planning has tremendously developed due to ever increasing computational capabilities. Simulators for education, planning, and training of surgery are often compared with flight simulators, where maneuvers are also trained to reduce a possible risk of failure. Meanwhile, digital patient models can be derived from medical image data with astonishing accuracy and thus can serve for model surgery to derive a surgical template model that represents the envisaged result. Computerized surgical planning approaches, however, are often still explorative, meaning that a surgeon tries to find a therapeutic concept based on his or her expertise using computational tools that are mimicking real procedures. Future perspectives of an improved computerized planning may be that surgical objectives will be generated algorithmically by employing mathematical modeling, simulation, and optimization techniques. Planning systems thus act as intelligent decision support systems. However, surgeons can still use the existing tools to vary the proposed approach, but they mainly focus on how to transfer objectives into reality. Such a development may result in a paradigm shift for future surgery planning. Y1 - 2015 U6 - https://doi.org/10.1055/s-0035-1564717 VL - 31 IS - 5 SP - 446 EP - 462 ER - TY - GEN A1 - Lamas-Rodríguez, Julián A1 - Ehlke, Moritz A1 - Hoffmann, René A1 - Zachow, Stefan T1 - GPU-accelerated denoising of large tomographic data sets with low SNR BT - Application for non-invasive analysis of paleontological data N2 - Enhancements in tomographic imaging techniques facilitate non-destructive methods for visualizing fossil structures. However, to penetrate dense materials such as sediments or pyrites, image acquisition is typically performed with high beam energy and very sensitive image intensifiers, leading to artifacts and noise in the acquired data. The analysis of delicate fossil structures requires the images to be captured in maximum resolution, resulting in large data sets of several giga bytes (GB) in size. Since the structural information of interest is often almost in the same spatial range as artifacts and noise, image processing and segmentation algorithms have to cope with a very low signal-to-noise ratio (SNR). Within this report we present a study on the performance of a collection of denoising algorithms applied to a very noisy fossil dataset. The study shows that a non-local means (NLM) filter, in case it is properly configured, is able to remove a considerable amount of noise while preserving most of the structural information of interest. Based on the results of this study, we developed a software tool within ZIBAmira that denoises large tomographic datasets using an adaptive, GPU-accelerated NLM filter. With the help of our implementation a user can interactively configure the filter's parameters and thus its effectiveness with respect to the data of interest, while the filtering response is instantly visualized for a preselected region of interest (ROI). Our implementation efficiently denoises even large fossil datasets in a reasonable amount of time. T3 - ZIB-Report - 15-14 Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-56339 SN - 1438-0064 ER - TY - JOUR A1 - Zahn, Robert A1 - Grotjohann, Sarah A1 - Ramm, Heiko A1 - Zachow, Stefan A1 - Putzier, Michael A1 - Perka, Carsten A1 - Tohtz, Stephan T1 - Pelvic tilt compensates for increased acetabular anteversion JF - International Orthopaedics N2 - Pelvic tilt determines functional orientation of the acetabulum. In this study, we investigated the interaction of pelvic tilt and functional acetabular anteversion (AA) in supine position. Y1 - 2015 U6 - https://doi.org/10.1007/s00264-015-2949-6 VL - 40 IS - 8 SP - 1571 EP - 1575 ER - TY - JOUR A1 - Zachow, Stefan A1 - Heppt, Werner T1 - The Facial Profile JF - Facial Plastic Surgery N2 - Facial appearance in our societies is often associated with notions of attractiveness, juvenileness, beauty, success, and so forth. Hence, the role of facial plastic surgery is highly interrelated to a patient's desire to feature many of these positively connoted attributes, which of course, are subject of different cultural perceptions or social trends. To judge about somebody's facial appearance, appropriate quantitative measures as well as methods to obtain and compare individual facial features are required. This special issue on facial profile is intended to provide an overview on how facial characteristics are surgically managed in an interdisciplinary way based on experience, instrumentation, and modern technology to obtain an aesthetic facial appearance with harmonious facial proportions. The facial profile will be discussed within the context of facial aesthetics. Latest concepts for capturing facial morphology in high speed and impressive detail are presented for quantitative analysis of even subtle changes, aging effects, or facial expressions. In addition, the perception of facial profiles is evaluated based on eye tracking technology. Y1 - 2015 U6 - https://doi.org/10.1055/s-0035-1566132 VL - 31 IS - 5 SP - 419 EP - 420 ER - TY - CHAP A1 - Ehlke, Moritz A1 - Frenzel, Thomas A1 - Ramm, Heiko A1 - Shandiz, Mohsen Akbari A1 - Anglin, Carolyn A1 - Zachow, Stefan T1 - Towards Robust Measurement Of Pelvic Parameters From AP Radiographs Using Articulated 3D Models T2 - Computer Assisted Radiology and Surgery (CARS) N2 - Patient-specific parameters such as the orientation of the acetabulum or pelvic tilt are useful for custom planning for total hip arthroplasty (THA) and for evaluating the outcome of surgical interventions. The gold standard in obtaining pelvic parameters is from three-dimensional (3D) computed tomography (CT) imaging. However, this adds time and cost, exposes the patient to a substantial radiation dose, and does not allow for imaging under load (e.g. while the patient is standing). If pelvic parameters could be reliably derived from the standard anteroposterior (AP) radiograph, preoperative planning would be more widespread, and research analyses could be applied to retrospective data, after a postoperative issue is discovered. The goal of this work is to enable robust measurement of two surgical parameters of interest: the tilt of the anterior pelvic plane (APP) and the orientation of the natural acetabulum. We present a computer-aided reconstruction method to determine the APP and natural acetabular orientation from a single, preoperative X-ray. It can easily be extended to obtain other important preoperative and postoperative parameters solely based on a single AP radiograph. KW - Articulated Models, Statistical Shape And Intensity Models, 2D/3D Anatomy Reconstruction, Pelvic Parameters Measurement, Total Hip Arthroplasty Y1 - 2015 ER - TY - GEN A1 - Ehlke, Moritz A1 - Frenzel, Thomas A1 - Ramm, Heiko A1 - Shandiz, Mohsen Akbari A1 - Anglin, Carolyn A1 - Zachow, Stefan T1 - Towards Robust Measurement of Pelvic Parameters from AP Radiographs using Articulated 3D Models N2 - Patient-specific parameters such as the orientation of the acetabulum or pelvic tilt are useful for custom planning for total hip arthroplasty (THA) and for evaluating the outcome of surgical interventions. The gold standard in obtaining pelvic parameters is from three-dimensional (3D) computed tomography (CT) imaging. However, this adds time and cost, exposes the patient to a substantial radiation dose, and does not allow for imaging under load (e.g. while the patient is standing). If pelvic parameters could be reliably derived from the standard anteroposterior (AP) radiograph, preoperative planning would be more widespread, and research analyses could be applied to retrospective data, after a postoperative issue is discovered. The goal of this work is to enable robust measurement of two surgical parameters of interest: the tilt of the anterior pelvic plane (APP) and the orientation of the natural acetabulum. We present a computer-aided reconstruction method to determine the APP and natural acetabular orientation from a single, preoperative X-ray. It can easily be extended to obtain other important preoperative and postoperative parameters solely based on a single AP radiograph. T3 - ZIB-Report - 15-11 KW - Articulated Models, Statistical Shape And Intensity Models, 2D/3D Anatomy Reconstruction, Pelvic Parameters Measurement, Total Hip Arthroplasty Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-53707 SN - 1438-0064 ER - TY - JOUR A1 - Lemanis, Robert A1 - Zachow, Stefan A1 - Fusseis, Florian A1 - Hoffmann, René T1 - A new approach using high-resolution computed tomography to test the buoyant properties of chambered cephalopod shells JF - Paleobiology N2 - The chambered shell of modern cephalopods functions as a buoyancy apparatus, allowing the animal to enter the water column without expending a large amount of energy to overcome its own weight. Indeed, the chambered shell is largely considered a key adaptation that allowed the earliest cephalopods to leave the ocean floor and enter the water column. It has been argued by some, however, that the iconic chambered shell of Paleozoic and Mesozoic ammonoids did not provide a sufficiently buoyant force to compensate for the weight of the entire animal, thus restricting ammonoids to a largely benthic lifestyle reminiscent of some octopods. Here we develop a technique using high-resolution computed tomography to quantify the buoyant properties of chambered shells without reducing the shell to ideal spirals or eliminating inherent biological variability by using mathematical models that characterize past work in this area. This technique has been tested on Nautilus pompilius and is now extended to the extant deep-sea squid Spirula spirula and the Jurassic ammonite Cadoceras sp. hatchling. Cadoceras is found to have possessed near-neutral to positive buoyancy if hatched when the shell possessed between three and five chambers. However, we show that the animal could also overcome degrees of negative buoyancy through swimming, similar to the paralarvae of modern squids. These calculations challenge past inferences of benthic life habits based solely on calculations of negative buoyancy. The calculated buoyancy of Cadoceras supports the possibility of planktonic dispersal of ammonite hatchlings. This information is essential to understanding ammonoid ecology as well as biotic interactions and has implications for the interpretation of geochemical data gained from the isotopic analysis of the shell. Y1 - 2015 U6 - https://doi.org/10.1017/pab.2014.17 VL - 41 IS - 2 SP - 313 EP - 329 PB - Cambridge University Press CY - Cambridge ER - TY - GEN A1 - Wilson, David A1 - Bücher, Pia A1 - Grewe, Carl Martin A1 - Anglin, Carolyn A1 - Zachow, Stefan A1 - Michael, Dunbar T1 - Validation of Three Dimensional Models of the Distal Femur Created from Surgical Navigation Point Cloud Data T2 - 15th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery (CAOS) Y1 - 2015 ER - TY - JOUR A1 - Grewe, Carl Martin A1 - Schreiber, Lisa A1 - Zachow, Stefan T1 - Fast and Accurate Digital Morphometry of Facial Expressions JF - Facial Plastic Surgery Y1 - 2015 U6 - https://doi.org/10.1055/s-0035-1564720 VL - 31 IS - 05 SP - 431 EP - 438 PB - Thieme Medical Publishers CY - New York ER - TY - GEN A1 - Wilson, David A1 - Bücher, Pia A1 - Grewe, Carl Martin A1 - Mocanu, Valentin A1 - Anglin, Carolyn A1 - Zachow, Stefan A1 - Dunbar, Michael T1 - Validation of Three Dimensional Models of the Distal Femur Created from Surgical Navigation Data T2 - Orthopedic Research Society Annual Meeting Y1 - 2015 CY - Las Vegas, Nevada ER - TY - GEN A1 - Ehlke, Moritz A1 - Heyland, Mark A1 - Märdian, Sven A1 - Duda, Georg A1 - Zachow, Stefan T1 - Assessing the Relative Positioning of an Osteosynthesis Plate to the Patient-Specific Femoral Shape from Plain 2D Radiographs N2 - We present a novel method to derive the surface distance of an osteosynthesis plate w.r.t. the patient­specific surface of the distal femur based on 2D X­ray images. Our goal is to study from clinical data, how the plate­to­bone distance affects bone healing. The patient­specific 3D shape of the femur is, however, seldom recorded for cases of femoral osteosynthesis since this typically requires Computed Tomography (CT), which comes at high cost and radiation dose. Our method instead utilizes two postoperative X­ray images to derive the femoral shape and thus can be applied on radiographs that are taken in clinical routine for follow­up. First, the implant geometry is used as a calibration object to relate the implant and the individual X­ray images spatially in a virtual X­ray setup. In a second step, the patient­specific femoral shape and pose are reconstructed in the virtual setup by fitting a deformable statistical shape and intensity model (SSIM) to the images. The relative positioning between femur and implant is then assessed in terms of displacement between the reconstructed 3D shape of the femur and the plate. A preliminary evaluation based on 4 cadaver datasets shows that the method derives the plate­to­bone distance with a mean absolute error of less than 1mm and a maximum error of 4.7 mm compared to ground truth from CT. We believe that the approach presented in this paper constitutes a meaningful tool to elucidate the effect of implant positioning on fracture healing. T3 - ZIB-Report - 15-21 KW - 3d-­reconstruction from 2d X­rays KW - statistical shape and intensity models KW - fracture fixation of the distal femur KW - pose estimation Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-54268 SN - 1438-0064 ER - TY - GEN A1 - Ehlke, Moritz A1 - Heyland, Mark A1 - Märdian, Sven A1 - Duda, Georg A1 - Zachow, Stefan T1 - 3D Assessment of Osteosynthesis based on 2D Radiographs N2 - We present a novel method to derive the surface distance of an osteosynthesis plate w.r.t. the patient-specific surface of the distal femur based on postoperative 2D radiographs. In a first step, the implant geometry is used as a calibration object to relate the implant and the individual X-ray images spatially in a virtual X-ray setup. Second, the patient-specific femoral shape and pose are reconstructed by fitting a deformable statistical shape and intensity model (SSIM) to the X-rays. The relative positioning between femur and implant is then assessed in terms of the displacement between the reconstructed 3D shape of the femur and the plate. We believe that the approach presented in this paper constitutes a meaningful tool to elucidate the effect of implant positioning on fracture healing and, ultimately, to derive load recommendations after surgery. T3 - ZIB-Report - 15-47 KW - 3d-reconstruction from 2d X-rays KW - statistical shape and intensity models KW - osteosynthesis follow-up Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-56217 SN - 1438-0064 ER - TY - CHAP A1 - Krämer, Martin A1 - Herrmann, Karl-Heinz A1 - Boeth, Heide A1 - Tycowicz, Christoph von A1 - König, Christian A1 - Zachow, Stefan A1 - Ehrig, Rainald A1 - Hege, Hans-Christian A1 - Duda, Georg A1 - Reichenbach, Jürgen T1 - Measuring 3D knee dynamics using center out radial ultra-short echo time trajectories with a low cost experimental setup T2 - ISMRM (International Society for Magnetic Resonance in Medicine), 23rd Annual Meeting 2015, Toronto, Canada Y1 - 2015 ER - TY - CHAP A1 - Ehlke, Moritz A1 - Heyland, Mark A1 - Märdian, Sven A1 - Duda, Georg A1 - Zachow, Stefan T1 - Assessing the relative positioning of an osteosynthesis plate to the patient-specific femoral shape from plain 2D radiographs T2 - Proceedings of the 15th Annual Meeting of CAOS-International (CAOS) N2 - We present a novel method to derive the surface distance of an osteosynthesis plate w.r.t. the patient­specific surface of the distal femur based on 2D X­ray images. Our goal is to study from clinical data, how the plate­to­bone distance affects bone healing. The patient­specific 3D shape of the femur is, however, seldom recorded for cases of femoral osteosynthesis since this typically requires Computed Tomography (CT), which comes at high cost and radiation dose. Our method instead utilizes two postoperative X­ray images to derive the femoral shape and thus can be applied on radiographs that are taken in clinical routine for follow­up. First, the implant geometry is used as a calibration object to relate the implant and the individual X­ray images spatially in a virtual X­ray setup. In a second step, the patient­specific femoral shape and pose are reconstructed in the virtual setup by fitting a deformable statistical shape and intensity model (SSIM) to the images. The relative positioning between femur and implant is then assessed in terms of displacement between the reconstructed 3D shape of the femur and the plate. A preliminary evaluation based on 4 cadaver datasets shows that the method derives the plate­to­bone distance with a mean absolute error of less than 1mm and a maximum error of 4.7 mm compared to ground truth from CT. We believe that the approach presented in this paper constitutes a meaningful tool to elucidate the effect of implant positioning on fracture healing. KW - 3d-­reconstruction from 2d X­rays KW - statistical shape and intensity models KW - fracture fixation of the distal femur KW - pose estimation Y1 - 2015 ER - TY - CHAP A1 - Ehlke, Moritz A1 - Heyland, Mark A1 - Märdian, Sven A1 - Duda, Georg A1 - Zachow, Stefan T1 - 3D Assessment of Osteosynthesis based on 2D Radiographs T2 - Proceedings of the Jahrestagung der Deutschen Gesellschaft für Computer- und Roboterassistierte Chirurgie (CURAC) N2 - We present a novel method to derive the surface distance of an osteosynthesis plate w.r.t. the patient-specific surface of the distal femur based on postoperative 2D radiographs. In a first step, the implant geometry is used as a calibration object to relate the implant and the individual X-ray images spatially in a virtual X-ray setup. Second, the patient- specific femoral shape and pose are reconstructed by fitting a deformable statistical shape and intensity model (SSIM) to the X-rays. The relative positioning between femur and implant is then assessed in terms of the displacement between the reconstructed 3D shape of the femur and the plate. We believe that the approach presented in this paper constitutes a meaningful tool to elucidate the effect of implant positioning on fracture healing and, ultimately, to derive load recommendations after surgery. KW - 3d-reconstruction from 2d X-rays KW - osteosynthesis follow-up KW - statistical shape and intensity models Y1 - 2015 SP - 317 EP - 321 ER - TY - JOUR A1 - Campoli, Gianni A1 - Baka, Nora A1 - Kaptein, Bart A1 - Valstar, Edward A1 - Zachow, Stefan A1 - Weinans, Harrie A1 - Zadpoor, Amir Abbas T1 - Relationship between the shape and density distribution of the femur and its natural frequencies of vibration JF - Journal of Biomechanics N2 - It has been recently suggested that mechanical loads applied at frequencies close to the natural frequencies of bone could enhance bone apposition due to the resonance phenomenon. Other applications of bone modal analysis are also suggested. For the above-mentioned applications, it is important to understand how patient-specific bone shape and density distribution influence the natural frequencies of bones. We used finite element models to study the effects of bone shape and density distribution on the natural frequencies of the femur in free boundary conditions. A statistical shape and appearance model that describes shape and density distribution independently was created, based on a training set of 27 femora. The natural frequencies were then calculated for different shape modes varied around the mean shape while keeping the mean density distribution, for different appearance modes around the mean density distribution while keeping the mean bone shape, and for the 27 training femora. Single shape or appearance modes could cause up to 15% variations in the natural frequencies with certain modes having the greatest impact. For the actual femora, shape and density distribution changed the natural frequencies by up to 38%. First appearance mode that describes the general cortical bone thickness and trabecular bone density had one of the strongest impacts. The first appearance mode could therefore provide a sensitive measure of general bone health and disease progression. Since shape and density could cause large variations in the calculated natural frequencies, patient-specific FE models are needed for accurate estimation of bone natural frequencies. Y1 - 2014 U6 - https://doi.org/10.1016/j.jbiomech.2014.08.008 VL - 47 SP - 3334 EP - 3343 PB - Elsevier ER - TY - JOUR A1 - Hochfeld, Mascha A1 - Lamecker, Hans A1 - Thomale, Ulrich W. A1 - Schulz, Matthias A1 - Zachow, Stefan A1 - Haberl, Hannes T1 - Frame-based cranial reconstruction JF - Journal of Neurosurgery: Pediatrics N2 - The authors report on the first experiences with the prototype of a surgical tool for cranial remodeling. The device enables the surgeon to transfer statistical information, represented in a model, into the disfigured bone. The model is derived from a currently evolving databank of normal head shapes. Ultimately, the databank will provide a set of standard models covering the statistical range of normal head shapes, thus providing the required template for any standard remodeling procedure as well as customized models for intended overcorrection. To date, this technique has been used in the surgical treatment of 14 infants (age range 6-12 months) with craniosynostosis. In all 14 cases, the designated esthetic result, embodied by the selected model, has been achieved, without morbidity or mortality. Frame-based reconstruction provides the required tools to precisely realize the surgical reproduction of the model shape. It enables the establishment of a self-referring system, feeding back postoperative growth patterns, recorded by 3D follow-up, into the model design. Y1 - 2014 U6 - https://doi.org/10.3171/2013.11.PEDS1369 VL - 13 IS - 3 SP - 319 EP - 323 ER - TY - CHAP A1 - Baum, Daniel A1 - Mahlow, Kristin A1 - Lamecker, Hans A1 - Zachow, Stefan A1 - Müller, Johannes A1 - Hege, Hans-Christian T1 - The Potential of Surface-based Geometric Morphometrics for Evolutionary Studies: An Example using Dwarf Snakes (Eirenis) T2 - Abstract in DigitalSpecimen 2014 N2 - Geometric morphometrics plays an important role in evolutionary studies. The state-of-the-art in this field are landmark-based methods. Since the landmarks usually need to be placed manually, only a limited number of landmarks are generally used to represent the shape of an anatomical structure. As a result, shape characteristics that cannot be properly represented by small sets of landmarks are disregarded. In this study, we present a method that is free of this limitation. The method takes into account the whole shape of an anatomical structure, which is represented as a surface, hence the term ‘surface-based morphometrics’. Correspondence between two surfaces is established by defining a partitioning of the surfaces into homologous surface patches. The first step for the generation of a surface partitioning is to place landmarks on the surface. Subsequently, the landmarks are connected by curves lying on the surface. The curves, called ‘surface paths’, might either follow specific anatomical features or they can be geodesics, that is, shortest paths on the surface. One important requirement, however, is that the resulting surface path networks are topologically equivalent across all surfaces. Once the surface path networks have been defined, the surfaces are decomposed into patches according to the path networks. This approach has several advantages. One of them is that we can discretize the surface by as many points as desired. Thus, even fine shape details can be resolved if this is of interest for the study. Since a point discretization is used, another advantage is that well-established analysis methods for landmark-based morphometrics can be utilized. Finally, the shapes can be easily morphed into one another, thereby greatly supporting the understanding of shape changes across all considered specimens. To show the potential of the described method for evolutionary studies of biological specimens, we applied the method to the para-basisphenoid complex of the snake genus Eirenis. By using this anatomical structure as example, we present all the steps that are necessary for surface-based morphometrics, including the segmentation of the para-basisphenoid complex from micro-CT data sets. We also show some first results using statistical analysis as well as classification methods based on the presented technique. Y1 - 2014 ER - TY - JOUR A1 - Hoffmann, René A1 - Schultz, Julia A. A1 - Schellhorn, Rico A1 - Rybacki, Erik A1 - Keupp, Helmut A1 - Gerden, S. R. A1 - Lemanis, Robert A1 - Zachow, Stefan T1 - Non-invasive imaging methods applied to neo- and paleontological cephalopod research JF - Biogeosciences N2 - Several non-invasive methods are common practice in natural sciences today. Here we present how they can be applied and contribute to current topics in cephalopod (paleo-) biology. Different methods will be compared in terms of time necessary to acquire the data, amount of data, accuracy/resolution, minimum/maximum size of objects that can be studied, the degree of post-processing needed and availability. The main application of the methods is seen in morphometry and volumetry of cephalopod shells. In particular we present a method for precise buoyancy calculation. Therefore, cephalopod shells were scanned together with different reference bodies, an approach developed in medical sciences. It is necessary to know the volume of the reference bodies, which should have similar absorption properties like the object of interest. Exact volumes can be obtained from surface scanning. Depending on the dimensions of the study object different computed tomography techniques were applied. Y1 - 2014 U6 - https://doi.org/10.5194/bg-11-2721-2014 N1 - To access the corresponding discussion paper go to www.biogeosciences-discuss.net/10/18803/2013/ - Biogeosciences Discuss., 10, 18803-18851, 2013 VL - 11 IS - 10 SP - 2721 EP - 2739 ER - TY - GEN A1 - Ehlke, Moritz A1 - Frenzel, Thomas A1 - Ramm, Heiko A1 - Lamecker, Hans A1 - Akbari Shandiz, Mohsen A1 - Anglin, Carolyn A1 - Zachow, Stefan T1 - Robust Measurement of Natural Acetabular Orientation from AP Radiographs using Articulated 3D Shape and Intensity Models T3 - ZIB-Report - 14-12 KW - articulated shape and intensity models KW - 3D reconstruction KW - acetabular orientation KW - image registration Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-49824 SN - 1438-0064 ER - TY - GEN A1 - Hoffmann, René A1 - Schultz, Julia A. A1 - Schellhorn, Rico A1 - Rybacki, Erik A1 - Keupp, Helmut A1 - Lemanis, Robert A1 - Zachow, Stefan T1 - Non-invasive imaging methods applied to neo- and paleo-ontological cephalopod research N2 - Several non-invasive methods are common practice in natural sciences today. Here we present how they can be applied and contribute to current topics in cephalopod (paleo-) biology. Different methods will be compared in terms of time necessary to acquire the data, amount of data, accuracy/resolution, minimum/maximum size of objects that can be studied, the degree of post-processing needed and availability. The main application of the methods is seen in morphometry and volumetry of cephalopod shells. In particular we present a method for precise buoyancy calculation. Therefore, cephalopod shells were scanned together with different reference bodies, an approach developed in medical sciences. It is necessary to know the volume of the reference bodies, which should have similar absorption properties like the object of interest. Exact volumes can be obtained from surface scanning. Depending on the dimensions of the study object different computed tomography techniques were applied. T3 - ZIB-Report - 14-18 Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-50300 SN - 1438-0064 ER - TY - JOUR A1 - Zinser, Max A1 - Zachow, Stefan A1 - Sailer, Hermann T1 - Bimaxillary "rotation advancement" procedures in patients with obstructive sleep apnea: A 3-dimensional airway analysis of morphological changes JF - International Journal of Oral & Maxillofacial Surgery Y1 - 2013 U6 - https://doi.org/10.1016/j.ijom.2012.08.002 VL - 42 IS - 5 SP - 569 EP - 578 ER - TY - JOUR A1 - Ehlke, Moritz A1 - Ramm, Heiko A1 - Lamecker, Hans A1 - Hege, Hans-Christian A1 - Zachow, Stefan T1 - Fast Generation of Virtual X-ray Images for Reconstruction of 3D Anatomy JF - IEEE Transactions on Visualization and Computer Graphics Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-35928 VL - 19 IS - 12 SP - 2673 EP - 2682 ER - TY - JOUR A1 - Galloway, Francis A1 - Kahnt, Max A1 - Ramm, Heiko A1 - Worsley, Peter A1 - Zachow, Stefan A1 - Nair, Prasanth A1 - Taylor, Mark T1 - A large scale finite element study of a cementless osseointegrated tibial tray JF - Journal of Biomechanics Y1 - 2013 U6 - https://doi.org//10.1016/j.jbiomech.2013.04.021 VL - 46 IS - 11 SP - 1900 EP - 1906 ER - TY - JOUR A1 - Hildebrandt, Thomas A1 - Goubergrits, Leonid A1 - Heppt, Werner A1 - Bessler, Stefan A1 - Zachow, Stefan T1 - Evaluation of the Intranasal Flow Field through Computational Fluid Dynamics (CFD) JF - Journal of Facial and Plastic Surgery Y1 - 2013 UR - https://www.thieme-connect.de/DOI/DOI?10.1055/s-0033-1341591 U6 - https://doi.org/10.1055/s-0033-1341591 VL - 29 IS - 2 SP - 93 EP - 98 PB - Thieme ER - TY - JOUR A1 - Saevarsson, Stefan A1 - Sharma, Gulshan A1 - Ramm, Heiko A1 - Lieck, Robert A1 - Hutchison, Carol A1 - Werle, Jason A1 - Montgomery, Sigrun A1 - Romeo, Carolina A1 - Zachow, Stefan A1 - Anglin, Carolyn T1 - Kinematic Differences Between Gender Specific And Traditional Knee Implants JF - The Journal of Arthroplasty Y1 - 2013 U6 - https://doi.org/10.1016/j.arth.2013.01.021 VL - 28 IS - 9 SP - 1543 EP - 1550 ER - TY - CHAP A1 - Ramm, Heiko A1 - Victoria Morillo, Oscar Salvador A1 - Todt, Ingo A1 - Schirmacher, Hartmut A1 - Ernst, Arneborg A1 - Zachow, Stefan A1 - Lamecker, Hans ED - Freysinger, Wolfgang T1 - Visual Support for Positioning Hearing Implants T2 - Proceedings of the 12th annual meeting of the CURAC society Y1 - 2013 SP - 116 EP - 120 ER - TY - JOUR A1 - Kainmüller, Dagmar A1 - Lamecker, Hans A1 - Heller, Markus O. A1 - Weber, Britta A1 - Hege, Hans-Christian A1 - Zachow, Stefan T1 - Omnidirectional Displacements for Deformable Surfaces JF - Medical Image Analysis Y1 - 2013 U6 - https://doi.org/10.1016/j.media.2012.11.006 VL - 17 IS - 4 SP - 429 EP - 441 PB - Elsevier ER - TY - JOUR A1 - Lamas-Rodríguez, Julián A1 - Heras, Dora Blanco A1 - Argüello, Francisco A1 - Kainmüller, Dagmar A1 - Zachow, Stefan A1 - Bóo, Montserrat T1 - GPU-accelerated level-set segmentation JF - Journal of Real-Time Image Processing Y1 - 2013 UR - http://dx.doi.org/10.1007/s11554-013-0378-6 U6 - https://doi.org/10.1007/s11554-013-0378-6 SN - 1861-8200 SP - 1 EP - 15 PB - Springer Berlin Heidelberg ER - TY - GEN A1 - Ehlke, Moritz A1 - Ramm, Heiko A1 - Lamecker, Hans A1 - Hege, Hans-Christian A1 - Zachow, Stefan T1 - Fast Generation of Virtual X-ray Images from Deformable Tetrahedral Meshes N2 - We propose a novel GPU-based approach to render virtual X-ray projections of deformable tetrahedral meshes. These meshes represent the shape and the internal density distribution of a particular anatomical structure and are derived from statistical shape and intensity models (SSIMs). We apply our method to improve the geometric reconstruction of 3D anatomy (e.g.\ pelvic bone) from 2D X-ray images. For that purpose, shape and density of a tetrahedral mesh are varied and virtual X-ray projections are generated within an optimization process until the similarity between the computed virtual X-ray and the respective anatomy depicted in a given clinical X-ray is maximized. The OpenGL implementation presented in this work deforms and projects tetrahedral meshes of high resolution (200.000+ tetrahedra) at interactive rates. It generates virtual X-rays that accurately depict the density distribution of an anatomy of interest. Compared to existing methods that accumulate X-ray attenuation in deformable meshes, our novel approach significantly boosts the deformation/projection performance. The proposed projection algorithm scales better with respect to mesh resolution and complexity of the density distribution, and the combined deformation and projection on the GPU scales better with respect to the number of deformation parameters. The gain in performance allows for a larger number of cycles in the optimization process. Consequently, it reduces the risk of being stuck in a local optimum. We believe that our approach contributes in orthopedic surgery, where 3D anatomy information needs to be extracted from 2D X-rays to support surgeons in better planning joint replacements. T3 - ZIB-Report - 13-38 KW - digitally reconstructed radiographs KW - volume rendering KW - mesh deformation KW - statistical shape and intensity models KW - image registration KW - GPU acceleration Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-41896 SN - 1438-0064 ER - TY - GEN A1 - Ramm, Heiko A1 - Morillo Victoria, Oscar Salvador A1 - Todt, Ingo A1 - Schirmacher, Hartmut A1 - Ernst, Arneborg A1 - Zachow, Stefan A1 - Lamecker, Hans T1 - Visual Support for Positioning Hearing Implants N2 - We present a software planning tool that provides intuitive visual feedback for finding suitable positions of hearing implants in the human temporal bone. After an automatic reconstruction of the temporal bone anatomy the tool pre-positions the implant and allows the user to adjust its position interactively with simple 2D dragging and rotation operations on the bone's surface. During this procedure, visual elements like warning labels on the implant or color encoded bone density information on the bone geometry provide guidance for the determination of a suitable fit. T3 - ZIB-Report - 13-53 KW - bone anchored hearing implant KW - surgery planning KW - segmentation KW - visualization Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-42495 SN - 1438-0064 ER - TY - GEN A1 - Grewe, Carl Martin A1 - Lamecker, Hans A1 - Zachow, Stefan ED - Hermanussen, Michael T1 - Landmark-based Statistical Shape Analysis T2 - Auxology - Studying Human Growth and Development url Y1 - 2013 UR - http://www.schweizerbart.de/publications/detail/isbn/9783510652785 SP - 199 EP - 201 PB - Schweizerbart Verlag, Stuttgart ER - TY - JOUR A1 - Saevarsson, Stefan A1 - Sharma, Gulshan A1 - Amiri, Shahram A1 - Montgomery, Sigrun A1 - Ramm, Heiko A1 - Lichti, Derek A1 - Lieck, Robert A1 - Zachow, Stefan A1 - Anglin, Carolyn T1 - Radiological method for measuring patellofemoral tracking and tibiofemoral kinematics before and after total knee replacement JF - Bone and Joint Research Y1 - 2012 UR - http://www.bjr.boneandjoint.org.uk/content/1/10/263.short U6 - https://doi.org/10.1302/2046-3758.110.2000117 VL - 1 IS - 10 SP - 263 EP - 271 ER - TY - GEN A1 - Deuflhard, Peter A1 - Zachow, Stefan T1 - Mathematische Therapie- und Operationsplanung Y1 - 2012 SP - 89 EP - 90 PB - Berliner Wirtschaftsgespräche e.V. CY - Berlin ER - TY - GEN A1 - Bindernagel, Matthias A1 - Kainmüller, Dagmar A1 - Ramm, Heiko A1 - Lamecker, Hans A1 - Zachow, Stefan T1 - Analysis of inter-individual anatomical shape variations of joint structures T2 - Proc. Int. Society of Computer Assisted Orthopaedic Surgery (CAOS) Y1 - 2012 IS - 210 ER - TY - CHAP A1 - Nguyen, The Duy A1 - Lamecker, Hans A1 - Kainmüller, Dagmar A1 - Zachow, Stefan ED - Ayache, Nicholas ED - Delingette, Hervé ED - Golland, Polina ED - Mori, Kensaku T1 - Automatic Detection and Classification of Teeth in CT Data T2 - Proc. Medical Image Computing and Computer Assisted Intervention (MICCAI) Y1 - 2012 VL - 7510 SP - 609 EP - 616 ER - TY - JOUR A1 - Nguyen, The Duy A1 - Kainmüller, Dagmar A1 - Lamecker, Hans A1 - Zachow, Stefan T1 - Automatic bone and tooth detection for CT-based dental implant planning JF - Int. J. Computer Assisted Radiology and Surgery Y1 - 2012 VL - 7, Supplement 1 IS - 1 SP - 293 EP - 294 PB - Springer ER - TY - GEN A1 - Sharma, Gulshan A1 - Ho, Karen A1 - Saevarsson, Stefan A1 - Ramm, Heiko A1 - Lieck, Robert A1 - Zachow, Stefan A1 - Anglin, Carolyn T1 - Knee Pose and Geometry Pre- and Post-Total Knee Arthroplasty Using Computed Tomography T2 - 58th Annual Meeting of the Orthopaedic Research Society (ORS) Y1 - 2012 CY - San Francisco, CA ER - TY - GEN A1 - Sharma, Gulshan A1 - Saevarsson, Stefan A1 - Amiri, Shahram A1 - Montgomery, Sigrun A1 - Ramm, Heiko A1 - Lichti, Derek A1 - Zachow, Stefan A1 - Anglin, Carolyn T1 - Sequential-Biplane Radiography for Measuring Pre and Post Total Knee Arthroplasty Kinematics T2 - 58th Annual Meeting of the Orthopaedic Research Society (ORS) Y1 - 2012 CY - San Francisco, CA ER - TY - CHAP A1 - Stefan, Saevarsson A1 - Gulshan, Sharma A1 - Sigrun, Montgomery A1 - Karen, Ho A1 - Ramm, Heiko A1 - Lieck, Robert A1 - Zachow, Stefan A1 - Hutchison, Carol A1 - Jason, Werle A1 - Carolyn, Anglin T1 - Kinematic Comparison Between Gender Specific and Traditional Femoral Implants T2 - 67th Canadian Orthopaedic Association (COA) Annual Meeting Y1 - 2012 ER - TY - JOUR A1 - Ho, Karen A1 - Saevarsson, Stefan A1 - Ramm, Heiko A1 - Lieck, Robert A1 - Zachow, Stefan A1 - Sharma, Gulshan A1 - Rex, Erica A1 - Amiri, Shahram A1 - Wu, Barnabas A1 - Leumann, Andre A1 - Anglin, Carolyn T1 - Computed tomography analysis of knee pose and geometry before and after total knee arthroplasty JF - Journal of biomechanics Y1 - 2012 UR - http://www.ncbi.nlm.nih.gov/pubmed/22796002 U6 - https://doi.org/10.1016/j.jbiomech.2012.06.004 VL - 45 IS - 13 SP - 2215 EP - 21 ER - TY - GEN A1 - Ehlke, Moritz A1 - Ramm, Heiko A1 - Lamecker, Hans A1 - Zachow, Stefan T1 - Efficient projection and deformation of volumetric shape and intensity models for accurate simulation of X-ray images T2 - Eurographics Workshop on Visual Computing for Biomedicine (NVIDIA best poster award) Y1 - 2012 ER - TY - JOUR A1 - Ramm, Heiko A1 - Kahnt, Max A1 - Zachow, Stefan T1 - Patientenspezifische Simulationsmodelle für die funktionelle Analyse von künstlichem Gelenkersatz JF - Computer Aided Medical Engineering (CaMe) Y1 - 2012 VL - 3 IS - 2 SP - 30 EP - 36 ER - TY - CHAP A1 - Kahnt, Max A1 - Ramm, Heiko A1 - Lamecker, Hans A1 - Zachow, Stefan ED - Levine, Joshua A. ED - Paulsen, Rasmus R. ED - Zhang, Yongjie T1 - Feature-Preserving, Multi-Material Mesh Generation using Hierarchical Oracles T2 - Proc. MICCAI Workshop on Mesh Processing in Medical Image Analysis (MeshMed) Y1 - 2012 VL - 7599 SP - 101 EP - 111 ER - TY - CHAP A1 - Ramm, Heiko A1 - Zachow, Stefan ED - Niederlag, Wolfgang ED - Lemke, Heinz ED - Peitgen, Heinz-Otto ED - Lehrach, Hans T1 - Computergestützte Planung für die individuelle Implantatversorgung T2 - Health Academy Y1 - 2012 VL - 16 SP - 145 EP - 158 ER - TY - GEN A1 - Ehlke, Moritz A1 - Ramm, Heiko A1 - Lamecker, Hans A1 - Zachow, Stefan T1 - Efficient projection and deformation of volumetric intensity models for accurate simulation of X-ray images N2 - We present an efficient GPU-based method to generate virtual X-ray images from tetrahedral meshes which are associated with attenuation values. In addition, a novel approach is proposed that performs the model deformation on the GPU. The tetrahedral grids are derived from volumetric statistical shape and intensity models (SSIMs) and describe anatomical structures. Our research targets at reconstructing 3D anatomical shapes by comparing virtual X-ray images generated using our novel approach with clinical data while varying the shape and density of the SSIM in an optimization process. We assume that a deformed SSIM adequately represents an anatomy of interest when the similarity between the virtual and the clinical X-ray image is maximized. The OpenGL implementation presented here generates accurate (virtual) X-ray images at interactive rates, thus qualifying it for its use in the reconstruction process. T3 - ZIB-Report - 12-40 KW - Digitally Reconstructed Radiograph (DRR), Anatomy Reconstruction, Statistical Shape and Intensity Model (SSIM), GPU acceleration Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-16580 SN - 1438-0064 ER - TY - CHAP A1 - Hoffmann, René A1 - Zachow, Stefan T1 - Non-invasive approach to shed new light on the buoyancy business of chambered cephalopods (Mollusca) T2 - Proc. of the Intl. Assoc. for Mathematical Geosciences, Salzburg Y1 - 2011 U6 - https://doi.org/10.5242/iamg.2011.0163 SP - 1 EP - 11 ER - TY - CHAP A1 - von Berg, Jens A1 - Dworzak, Jalda A1 - Klinder, Tobias A1 - Manke, Dirk A1 - Lamecker, Hans A1 - Zachow, Stefan A1 - Lorenz, Cristian T1 - Temporal Subtraction of Chest Radiographs Compensating Pose Differences T2 - SPIE Medical Imaging Y1 - 2011 ER - TY - CHAP A1 - Bindernagel, Matthias A1 - Kainmüller, Dagmar A1 - Seim, Heiko A1 - Lamecker, Hans A1 - Zachow, Stefan A1 - Hege, Hans-Christian T1 - An Articulated Statistical Shape Model of the Human Knee T2 - Bildverarbeitung für die Medizin 2011 Y1 - 2011 U6 - https://doi.org/10.1007/978-3-642-19335-4_14 SP - 59 EP - 63 PB - Springer ER - TY - CHAP A1 - Kahnt, Max A1 - Galloway, Francis A1 - Seim, Heiko A1 - Lamecker, Hans A1 - Taylor, Mark A1 - Zachow, Stefan T1 - Robust and Intuitive Meshing of Bone-Implant Compounds T2 - CURAC Y1 - 2011 SP - 71 EP - 74 CY - Magdeburg ER - TY - GEN A1 - SK, Saevarsson A1 - GB, Sharma A1 - S, Montgomery A1 - KCT, Ho A1 - Ramm, Heiko A1 - Lieck, Robert A1 - Zachow, Stefan A1 - C, Anglin T1 - Kinematic Comparison Between Gender Specific and Traditional Femoral Implants T2 - Proceedings of the 11th Alberta Biomedical Engineering (BME) Conference (Poster) Y1 - 2011 SP - 80 ER - TY - GEN A1 - Grewe, Carl Martin A1 - Lamecker, Hans A1 - Zachow, Stefan T1 - Digital morphometry: The Potential of Statistical Shape Models T2 - Anthropologischer Anzeiger. Journal of Biological and Clinical Anthropology Y1 - 2011 SP - 506 EP - 506 ER - TY - JOUR A1 - Taylor, William R. A1 - Pöpplau, Berry M. A1 - König, Christian A1 - Ehrig, Rainald A1 - Zachow, Stefan A1 - Duda, Georg A1 - Heller, Markus O. T1 - The medial-lateral force distribution in the ovine stifle joint during walking JF - Journal of Orthopaedic Research Y1 - 2011 U6 - https://doi.org/10.1002/jor.21254 VL - 29 IS - 4 SP - 567 EP - 571 ER - TY - JOUR A1 - Rybak, Jürgen A1 - Kuß, Anja A1 - Lamecker, Hans A1 - Zachow, Stefan A1 - Hege, Hans-Christian A1 - Lienhard, Matthias A1 - Singer, Jochen A1 - Neubert, Kerstin A1 - Menzel, Randolf T1 - The Digital Bee Brain: Integrating and Managing Neurons in a Common 3D Reference System JF - Front. Syst. Neurosci. Y1 - 2010 U6 - https://doi.org/10.3389/fnsys.2010.00030 VL - 4 IS - 30 ER - TY - CHAP A1 - Deuflhard, Peter A1 - Dössel, Olaf A1 - Louis, Alfred A1 - Zachow, Stefan T1 - More Mathematics into Medicine! T2 - Production Factor Mathematics Y1 - 2010 UR - http://www.springer.com/mathematics/book/978-3-642-11247-8 SP - 357 EP - 378 PB - Springer ER - TY - CHAP A1 - Seim, Heiko A1 - Kainmüller, Dagmar A1 - Lamecker, Hans A1 - Bindernagel, Matthias A1 - Malinowski, Jana A1 - Zachow, Stefan ED - v. Ginneken, B. T1 - Model-based Auto-Segmentation of Knee Bones and Cartilage in MRI Data T2 - Proc. MICCAI Workshop Medical Image Analysis for the Clinic Y1 - 2010 SP - 215 EP - 223 ER - TY - JOUR A1 - Weiser, Martin A1 - Zachow, Stefan A1 - Deuflhard, Peter T1 - Craniofacial Surgery Planning Based on Virtual Patient Models JF - it - Information Technology Y1 - 2010 U6 - https://doi.org/10.1524/itit.2010.0600 VL - 52 IS - 5 SP - 258 EP - 263 PB - Oldenbourg Verlagsgruppe ER - TY - CHAP A1 - Zachow, Stefan A1 - Hahn, Horst A1 - Lange, Thomas ED - Schlag, Peter ED - Eulenstein, Sebastian ED - Lange, Thomas T1 - Computerassistierte Chirugieplanung T2 - Computerassistierte Chirurgie Y1 - 2010 SP - 119 EP - 149 PB - Elsevier ER - TY - CHAP A1 - Kainmüller, Dagmar A1 - Lamecker, Hans A1 - Seim, Heiko A1 - Zachow, Stefan A1 - Hege, Hans-Christian ED - Navab, Tianzi ED - P. W. Pluim, Josien ED - Viergever, Max T1 - Improving Deformable Surface Meshes through Omni-directional Displacements and MRFs T2 - Proc. Medical Image Computing and Computer Assisted Intervention (MICCAI) Y1 - 2010 U6 - https://doi.org/10.1007/978-3-642-15705-9_28 VL - 6361 SP - 227 EP - 234 PB - Springer ER - TY - CHAP A1 - Zachow, Stefan A1 - Kubiack, Kim A1 - Malinowski, Jana A1 - Lamecker, Hans A1 - Essig, Harald A1 - Gellrich, Nils-Claudius T1 - Modellgestützte chirurgische Rekonstruktion komplexer Mittelgesichtsfrakturen T2 - Proc. BMT, Biomed Tech 2010 Y1 - 2010 VL - 55 (Suppl 1) SP - 107 EP - 108 PB - Walter de Gruyter-Verlag ER - TY - CHAP A1 - Lamecker, Hans A1 - Kainmüller, Dagmar A1 - Seim, Heiko A1 - Zachow, Stefan T1 - Automatische 3D Rekonstruktion des Unterkiefers und der Mandibulärnerven auf Basis dentaler Bildgebung T2 - Proc. BMT, Biomed Tech Y1 - 2010 VL - 55 (Suppl. 1) SP - 35 EP - 36 PB - Walter de Gruyter-Verlag ER - TY - JOUR A1 - Zachow, Stefan A1 - Lamecker, Hans A1 - Zöckler, Maja A1 - Haberl, Ernst T1 - Computergestützte Planung zur chirurgischen Korrektur von frühkindlichen Schädelfehlbildungen (Craniosynostosen) JF - Face 02/09, Int. Mag. of Orofacial Esthetics, Oemus Journale Leipzig Y1 - 2009 SP - 48 EP - 53 ER - TY - JOUR A1 - Kainmüller, Dagmar A1 - Lamecker, Hans A1 - Seim, Heiko A1 - Zachow, Stefan T1 - Multi-object segmentation of head bones JF - MIDAS Journal Y1 - 2009 ER - TY - CHAP A1 - Seim, Heiko A1 - Kainmüller, Dagmar A1 - Lamecker, Hans A1 - Zachow, Stefan T1 - A System for Unsupervised Extraction of Orthopaedic Parameters from CT Data T2 - GI Workshop Softwareassistenten - Computerunterstützung für die medizinische Diagnose und Therapieplanung Y1 - 2009 SP - 1328 EP - 1337 CY - Lübeck, Germany ER - TY - CHAP A1 - Kainmüller, Dagmar A1 - Lamecker, Hans A1 - Seim, Heiko A1 - Zinser, Max A1 - Zachow, Stefan ED - Yang, Guang-Zhong ED - J. Hawkes, David ED - Rueckert, Daniel ED - Noble, J. Alison ED - J. Taylor, Chris T1 - Automatic Extraction of Mandibular Nerve and Bone from Cone-Beam CT Data T2 - Proceedings of Medical Image Computing and Computer Assisted Intervention (MICCAI) Y1 - 2009 SP - 76 EP - 83 CY - London, UK ER - TY - CHAP A1 - Kainmüller, Dagmar A1 - Lamecker, Hans A1 - Zachow, Stefan A1 - Hege, Hans-Christian T1 - An Articulated Statistical Shape Model for Accurate Hip Joint Segmentation T2 - EBMC 2009. Int. Conf. of the IEEE Eng. in Med. and Biol. Society (EMBC) Y1 - 2009 SP - 6345 EP - 6351 CY - Minneapolis, USA ER - TY - CHAP A1 - Seim, Heiko A1 - Kainmüller, Dagmar A1 - Heller, Markus O. A1 - Zachow, Stefan A1 - Hege, Hans-Christian T1 - Automatic Extraction of Anatomical Landmarks from Medical Image Data: An Evaluation of Different Methods T2 - Proc. of IEEE Int. Symposium on Biomedical Imaging (ISBI) Y1 - 2009 SP - 538 EP - 541 CY - Boston, MA, USA ER - TY - JOUR A1 - Kainmüller, Dagmar A1 - Lamecker, Hans A1 - Zachow, Stefan T1 - Multi-object Segmentation with Coupled Deformable Models JF - Annals of the British Machine Vision Association (BMVA) Y1 - 2009 VL - 5 SP - 1 EP - 10 ER - TY - JOUR A1 - Zachow, Stefan A1 - Muigg, Philipp A1 - Hildebrandt, Thomas A1 - Doleisch, Helmut A1 - Hege, Hans-Christian T1 - Visual Exploration of Nasal Airflow JF - IEEE Transactions on Visualization and Computer Graphics Y1 - 2009 U6 - https://doi.org/10.1109/TVCG.2009.198 VL - 15 IS - 8 SP - 1407 EP - 1414 ER - TY - JOUR A1 - Dworzak, Jalda A1 - Lamecker, Hans A1 - von Berg, Jens A1 - Klinder, Tobias A1 - Lorenz, Cristian A1 - Kainmüller, Dagmar A1 - Seim, Heiko A1 - Hege, Hans-Christian A1 - Zachow, Stefan T1 - 3D Reconstruction of the Human Rib Cage from 2D Projection Images using a Statistical Shape Model JF - Int. J. Comput. Assist. Radiol. Surg. Y1 - 2010 U6 - https://doi.org/10.1007/s11548-009-0390-2 SN - 1861-6410 VL - 5 IS - 2 SP - 111 EP - 124 PB - Springer ER - TY - GEN A1 - Deuflhard, Peter A1 - Dössel, Olaf A1 - Louis, Alfred A1 - Zachow, Stefan T1 - Mehr Mathematik wagen in der Medizin N2 - Der Artikel gibt einen Einblick in das reiche Feld der Zusammenarbeit zwischen Mathematik und Medizin. Beispielhaft werden drei Erfolgsmodelle dargestellt: Medizinische Bildgebung, mathematische Modellierung und Biosignalverarbeitung im Bereich der Dynamik des Herzens sowie mathematische Modellierung und Simulation in der Krebstherapie Hyperthermie und der Mund-Kiefer-Gesichts-Chirurgie. In allen Fällen existiert ein Gleichklang der Interessen von Medizin und Mathematik: Beide Disziplinen wollen die Resultate schnell und zuverlässig. Für die Klinik heißt das, dass notwendige Rechnungen in möglichst kurzer Zeit, und zwar auf dem PC, ablaufen müssen und dass die Resultate so genau und belastbar sein müssen, dass medizinische Entscheidungen darauf aufbauen können. Für die Mathematik folgt daraus, dass höchste Anforderungen an die Effizienz der verwendeten Algorithmen und die darauf aufbauende Software in Numerik und Visualisierung zu stellen sind. Jedes Kapitel endet mit einer Darstellung der Perspektive des jeweiligen Gebietes. Abschließend werden mögliche Handlungsoptionen für Politik und Wirtschaft diskutiert. T3 - ZIB-Report - 08-25 Y1 - 2008 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-10776 SN - 1438-0064 ER - TY - CHAP A1 - Zachow, Stefan A1 - Weiser, Martin A1 - Deuflhard, Peter ED - Niederlag, Wolfgang ED - Lemke, Heinz ED - Meixensberger, Jürgen ED - Baumann, Michael T1 - Modellgestützte Operationsplanung in der Kopfchirurgie T2 - Modellgestützte Therapie Y1 - 2008 SP - 140 EP - 156 PB - Health Academy ER - TY - CHAP A1 - Deuflhard, Peter A1 - Dössel, Olaf A1 - Louis, Alfred A1 - Zachow, Stefan T1 - Mehr Mathematik wagen in der Medizin T2 - acatech diskutiert, Produktionsfaktor Mathematik - Wie Mathematik Technik und Wirtschaft bewegt Y1 - 2008 U6 - https://doi.org/10.1007/978-3-540-89435-3 SP - 435 EP - 459 PB - Springer ER - TY - CHAP A1 - Kainmüller, Dagmar A1 - Lamecker, Hans A1 - Zachow, Stefan A1 - Hege, Hans-Christian T1 - Coupling Deformable Models for Multi-object Segmentation T2 - Proc. Int. Symp. on Computational Models for Biomedical Simulation (ISBMS) Y1 - 2008 U6 - https://doi.org/10.1007/978-3-540-70521-5_8 SP - 69 EP - 78 ER - TY - CHAP A1 - Kainmüller, Dagmar A1 - Lamecker, Hans A1 - Zachow, Stefan A1 - Heller, Markus O. A1 - Hege, Hans-Christian T1 - Multi-Object Segmentation with Coupled Deformable Models T2 - Proc. Medical Image Understanding and Analysis Y1 - 2008 SP - 34 EP - 38 ER - TY - CHAP A1 - Seim, Heiko A1 - Kainmüller, Dagmar A1 - Kuss, Anja A1 - Lamecker, Hans A1 - Zachow, Stefan A1 - Menzel, Randolf A1 - Rybak, Juergen T1 - Model-based autosegmentation of the central brain of the honeybee, Apis mellifera, using active statistical shape models T2 - Proc. 1st INCF Congress of Neuroinformatics: Databasing and Modeling the Brain Y1 - 2008 U6 - https://doi.org/10.3389/conf.neuro.11.2008.01.064 ER - TY - CHAP A1 - Dworzak, Jalda A1 - Lamecker, Hans A1 - von Berg, Jens A1 - Klinder, Tobias A1 - Lorenz, Cristian A1 - Kainmüller, Dagmar A1 - Seim, Heiko A1 - Hege, Hans-Christian A1 - Zachow, Stefan T1 - Towards model-based 3-D reconstruction of the human rib cage from radiographs T2 - Proc. 7. Jahrestagung der Deutschen Gesellschaft für Computer-Roboterassistierte Chirurgie (CURAC) Y1 - 2008 SP - 193 EP - 196 ER - TY - CHAP A1 - Seim, Heiko A1 - Kainmüller, Dagmar A1 - Heller, Markus O. A1 - Lamecker, Hans A1 - Zachow, Stefan A1 - Hege, Hans-Christian T1 - Automatic Segmentation of the Pelvic Bones from CT Data Based on a Statistical Shape Model T2 - Eurographics Workshop on Visual Computing for Biomedicine (VCBM) Y1 - 2008 SP - 93 EP - 100 CY - Delft, Netherlands ER - TY - JOUR A1 - Zachow, Stefan A1 - Deuflhard, Peter T1 - Computergestützte Planung in der kraniofazialen Chirurgie JF - Face 01/08, Int. Mag. of Orofacial Esthetics Y1 - 2008 SP - 43 EP - 49 PB - Oemus Journale Leipzig ER - TY - CHAP A1 - Zilske, Michael A1 - Lamecker, Hans A1 - Zachow, Stefan T1 - Adaptive Remeshing of Non-Manifold Surfaces T2 - Eurographics 2008 Annex to the Conf. Proc. Y1 - 2008 SP - 207 EP - 211 ER - TY - CHAP A1 - Seim, Heiko A1 - Lamecker, Hans A1 - Zachow, Stefan T1 - Segmentation of Bony Structures with Ligament Attachment Sites T2 - Bildverarbeitung für die Medizin 2008 Y1 - 2008 U6 - https://doi.org/10.1007/978-3-540-78640-5_42 SP - 207 EP - 211 PB - Springer ER - TY - CHAP A1 - Neugebauer, Mathias A1 - Janiga, Gabor A1 - Zachow, Stefan A1 - Krischek, Özlem A1 - Preim, Bernhard ED - Hauser, Helwig T1 - Generierung qualitativ hochwertiger Modelle für die Simulation von Blutfluss in zerebralen Aneurysmen T2 - Proc. of Simulation and Visualization 2008 Y1 - 2008 SP - 221 EP - 235 ER - TY - CHAP A1 - Dornheim, Jana A1 - Born, Silvia A1 - Zachow, Stefan A1 - Gessat, Michael A1 - Wellein, Daniela A1 - Strauß, Gero A1 - Preim, Bernhard A1 - Bartz, Dirk ED - Hauser, Helwig T1 - Bildanalyse, Visualisierung und Modellerstellung für die Implantatplanung im Mittelohr T2 - Proc. of Simulation and Visualization 2008 Y1 - 2008 SP - 139 EP - 154 ER - TY - JOUR A1 - Steinmann, Alexander A1 - Bartsch, Peter A1 - Zachow, Stefan A1 - Hildebrandt, Thomas T1 - Breathing Easily: Simulation of airflow in human noses can become a useful rhinosurgery planning tool JF - ANSYS Advantage Y1 - 2008 VL - Vol. II, No. 1 SP - 30 EP - 31 ER - TY - GEN A1 - Zachow, Stefan A1 - Zilske, Michael A1 - Hege, Hans-Christian T1 - 3D reconstruction of individual anatomy from medical image data: Segmentation and geometry processing N2 - For medical diagnosis, visualization, and model-based therapy planning three-dimensional geometric reconstructions of individual anatomical structures are often indispensable. Computer-assisted, model-based planning procedures typically cover specific modifications of “virtual anatomy” as well as numeric simulations of associated phenomena, like e.g. mechanical loads, fluid dynamics, or diffusion processes, in order to evaluate a potential therapeutic outcome. Since internal anatomical structures cannot be measured optically or mechanically in vivo, three-dimensional reconstruction of tomographic image data remains the method of choice. In this work the process chain of individual anatomy reconstruction is described which consists of segmentation of medical image data, geometrical reconstruction of all relevant tissue interfaces, up to the generation of geometric approximations (boundary surfaces and volumetric meshes) of three-dimensional anatomy being suited for finite element analysis. All results presented herein are generated with amira ® – a highly interactive software system for 3D data analysis, visualization and geometry reconstruction. T3 - ZIB-Report - 07-41 KW - Medical image segmentation KW - computational geometry KW - virtual anatomy KW - finite element meshes Y1 - 2007 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-10440 SN - 1438-0064 ER - TY - JOUR A1 - Heppt, Werner A1 - Hildebrandt, Thomas A1 - Steinmann, Alexander A1 - Zachow, Stefan T1 - Aesthetic and Function in Rhinoplasty JF - Springer Journal Y1 - 2007 VL - 264 (Suppl 1), RL 126 SP - 307 ER -