TY - JOUR A1 - Galloway, Francis A1 - Kahnt, Max A1 - Ramm, Heiko A1 - Worsley, Peter A1 - Zachow, Stefan A1 - Nair, Prasanth A1 - Taylor, Mark T1 - A large scale finite element study of a cementless osseointegrated tibial tray JF - Journal of Biomechanics Y1 - 2013 U6 - https://doi.org//10.1016/j.jbiomech.2013.04.021 VL - 46 IS - 11 SP - 1900 EP - 1906 ER - TY - GEN A1 - Tack, Alexander A1 - Shestakov, Alexey A1 - Lüdke, David A1 - Zachow, Stefan T1 - A deep multi-task learning method for detection of meniscal tears in MRI data from the Osteoarthritis Initiative database N2 - We present a novel and computationally efficient method for the detection of meniscal tears in Magnetic Resonance Imaging (MRI) data. Our method is based on a Convolutional Neural Network (CNN) that operates on a complete 3D MRI scan. Our approach detects the presence of meniscal tears in three anatomical sub-regions (anterior horn, meniscal body, posterior horn) for both the Medial Meniscus (MM) and the Lateral Meniscus (LM) individually. For optimal performance of our method, we investigate how to preprocess the MRI data or how to train the CNN such that only relevant information within a Region of Interest (RoI) of the data volume is taken into account for meniscal tear detection. We propose meniscal tear detection combined with a bounding box regressor in a multi-task deep learning framework to let the CNN implicitly consider the corresponding RoIs of the menisci. We evaluate the accuracy of our CNN-based meniscal tear detection approach on 2,399 Double Echo Steady-State (DESS) MRI scans from the Osteoarthritis Initiative database. In addition, to show that our method is capable of generalizing to other MRI sequences, we also adapt our model to Intermediate-Weighted Turbo Spin-Echo (IW TSE) MRI scans. To judge the quality of our approaches, Receiver Operating Characteristic (ROC) curves and Area Under the Curve (AUC) values are evaluated for both MRI sequences. For the detection of tears in DESS MRI, our method reaches AUC values of 0.94, 0.93, 0.93 (anterior horn, body, posterior horn) in MM and 0.96, 0.94, 0.91 in LM. For the detection of tears in IW TSE MRI data, our method yields AUC values of 0.84, 0.88, 0.86 in MM and 0.95, 0.91, 0.90 in LM. In conclusion, the presented method achieves high accuracy for detecting meniscal tears in both DESS and IW TSE MRI data. Furthermore, our method can be easily trained and applied to other MRI sequences. T3 - ZIB-Report - 21-33 Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-84415 SN - 1438-0064 ER - TY - JOUR A1 - Tack, Alexander A1 - Shestakov, Alexey A1 - Lüdke, David A1 - Zachow, Stefan T1 - A deep multi-task learning method for detection of meniscal tears in MRI data from the Osteoarthritis Initiative database JF - Frontiers in Bioengineering and Biotechnology, section Biomechanics N2 - We present a novel and computationally efficient method for the detection of meniscal tears in Magnetic Resonance Imaging (MRI) data. Our method is based on a Convolutional Neural Network (CNN) that operates on a complete 3D MRI scan. Our approach detects the presence of meniscal tears in three anatomical sub-regions (anterior horn, meniscal body, posterior horn) for both the Medial Meniscus (MM) and the Lateral Meniscus (LM) individually. For optimal performance of our method, we investigate how to preprocess the MRI data or how to train the CNN such that only relevant information within a Region of Interest (RoI) of the data volume is taken into account for meniscal tear detection. We propose meniscal tear detection combined with a bounding box regressor in a multi-task deep learning framework to let the CNN implicitly consider the corresponding RoIs of the menisci. We evaluate the accuracy of our CNN-based meniscal tear detection approach on 2,399 Double Echo Steady-State (DESS) MRI scans from the Osteoarthritis Initiative database. In addition, to show that our method is capable of generalizing to other MRI sequences, we also adapt our model to Intermediate-Weighted Turbo Spin-Echo (IW TSE) MRI scans. To judge the quality of our approaches, Receiver Operating Characteristic (ROC) curves and Area Under the Curve (AUC) values are evaluated for both MRI sequences. For the detection of tears in DESS MRI, our method reaches AUC values of 0.94, 0.93, 0.93 (anterior horn, body, posterior horn) in MM and 0.96, 0.94, 0.91 in LM. For the detection of tears in IW TSE MRI data, our method yields AUC values of 0.84, 0.88, 0.86 in MM and 0.95, 0.91, 0.90 in LM. In conclusion, the presented method achieves high accuracy for detecting meniscal tears in both DESS and IW TSE MRI data. Furthermore, our method can be easily trained and applied to other MRI sequences. Y1 - 2021 U6 - https://doi.org/10.3389/fbioe.2021.747217 SP - 28 EP - 41 ER - TY - CHAP A1 - Joachimsky, Robert A1 - Ma, Lihong A1 - Icking, Christian A1 - Zachow, Stefan T1 - A Collision-Aware Articulated Statistical Shape Model of the Human Spine T2 - Proc. of the 18th annual conference on Computer- and Robot-assisted Surgery (CURAC) N2 - Statistical Shape Models (SSMs) are a proven means for model-based 3D anatomy reconstruction from medical image data. In orthopaedics and biomechanics, SSMs are increasingly employed to individualize measurement data or to create individualized anatomical models to which implants can be adapted to or functional tests can be performed on. For modeling and analysis of articulated structures, so called articulated SSMs (aSSMs) have been developed. However, a missing feature of aSSMs is the consideration of collisions in the course of individual fitting and articulation. The aim of our work was to develop aSSMs that handle collisions between components correctly. That way it becomes possible to adjust shape and articulation in view of a physically and geometrically plausible individualization. To be able to apply collision-aware aSSMs in simulation and optimisation, our approach is based on an e� cient collision detection method employing Graphics Processing Units (GPUs). Y1 - 2019 SP - 58 EP - 64 ER - TY - CHAP A1 - Gladilin, Evgeny A1 - Zachow, Stefan A1 - Deuflhard, Peter A1 - Hege, Hans-Christian T1 - A Biomechanical Model for Soft Tissue Simulation in Craniofacial Surgery T2 - Medical Imaging and Augmented Reality (MIAR) Y1 - 2001 U6 - https://doi.org/10.1109/MIAR.2001.930276 SP - 137 EP - 141 CY - Hong Kong, China ER - TY - CHAP A1 - Hein, Andreas A1 - Lueth, Tim A1 - Zachow, Stefan A1 - Stien, Malte T1 - A 2D Planning Sytem for Robot-Assisted Interventions T2 - Computer Assisted Radiology and Surgery Y1 - 1999 SP - 1049 PB - Elsevier Science B.V. ER - TY - JOUR A1 - Dworzak, Jalda A1 - Lamecker, Hans A1 - von Berg, Jens A1 - Klinder, Tobias A1 - Lorenz, Cristian A1 - Kainmüller, Dagmar A1 - Seim, Heiko A1 - Hege, Hans-Christian A1 - Zachow, Stefan T1 - 3D Reconstruction of the Human Rib Cage from 2D Projection Images using a Statistical Shape Model JF - Int. J. Comput. Assist. Radiol. Surg. Y1 - 2010 U6 - https://doi.org/10.1007/s11548-009-0390-2 SN - 1861-6410 VL - 5 IS - 2 SP - 111 EP - 124 PB - Springer ER - TY - GEN A1 - Zachow, Stefan A1 - Zilske, Michael A1 - Hege, Hans-Christian T1 - 3D reconstruction of individual anatomy from medical image data: Segmentation and geometry processing N2 - For medical diagnosis, visualization, and model-based therapy planning three-dimensional geometric reconstructions of individual anatomical structures are often indispensable. Computer-assisted, model-based planning procedures typically cover specific modifications of “virtual anatomy” as well as numeric simulations of associated phenomena, like e.g. mechanical loads, fluid dynamics, or diffusion processes, in order to evaluate a potential therapeutic outcome. Since internal anatomical structures cannot be measured optically or mechanically in vivo, three-dimensional reconstruction of tomographic image data remains the method of choice. In this work the process chain of individual anatomy reconstruction is described which consists of segmentation of medical image data, geometrical reconstruction of all relevant tissue interfaces, up to the generation of geometric approximations (boundary surfaces and volumetric meshes) of three-dimensional anatomy being suited for finite element analysis. All results presented herein are generated with amira ® – a highly interactive software system for 3D data analysis, visualization and geometry reconstruction. T3 - ZIB-Report - 07-41 KW - Medical image segmentation KW - computational geometry KW - virtual anatomy KW - finite element meshes Y1 - 2007 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-10440 SN - 1438-0064 ER - TY - CHAP A1 - Zachow, Stefan A1 - Zilske, Michael A1 - Hege, Hans-Christian T1 - 3D Reconstruction of Individual Anatomy from Medical Image Data: Segmentation and Geometry Processing T2 - 25. ANSYS Conference & CADFEM Users’ Meeting Y1 - 2007 CY - Dresden ER - TY - JOUR A1 - Westermark, Anders A1 - Zachow, Stefan A1 - Eppley, Barry T1 - 3D osteotomy planning in maxillofacial surgery, including 3D soft tissue prediction JF - Journal of Craniofacial Surgery Y1 - 2005 VL - 16(1) SP - 100 EP - 104 ER -