TY - JOUR A1 - Buchmann, Jens A1 - Kaplan, Bernhard A1 - Powell, Samuel A1 - Prohaska, Steffen A1 - Laufer, Jan T1 - Quantitative PA tomography of high resolution 3-D images: experimental validation in tissue phantoms JF - Photoacoustics N2 - Quantitative photoacoustic tomography aims recover the spatial distribution of absolute chromophore concentrations and their ratios from deep tissue, high-resolution images. In this study, a model-based inversion scheme based on a Monte-Carlo light transport model is experimentally validated on 3-D multispectral images of a tissue phantom acquired using an all-optical scanner with a planar detection geometry. A calibrated absorber allowed scaling of the measured data during the inversion, while an acoustic correction method was employed to compensate the effects of limited view detection. Chromophore- and fluence-dependent step sizes and Adam optimization were implemented to achieve rapid convergence. High resolution 3-D maps of absolute concentrations and their ratios were recovered with high accuracy. Potential applications of this method include quantitative functional and molecular photoacoustic tomography of deep tissue in preclinical and clinical studies. Y1 - 2020 U6 - https://doi.org/10.1016/j.pacs.2019.100157 VL - 17 SP - 100157 ER - TY - JOUR A1 - Buchmann, Jens A1 - Kaplan, Bernhard A1 - Powell, Samuel A1 - Prohaska, Steffen A1 - Laufer, Jan T1 - 3D quantitative photoacoustic tomography using an adjoint radiance Monte Carlo model and gradient descent JF - Journal of Biomedical Optics N2 - Quantitative photoacoustic tomography aims to recover maps of the local concentrations of tissue chromophores from multispectral images. While model-based inversion schemes are promising approaches, major challenges to their practical implementation include the unknown fluence distribution and the scale of the inverse problem. This paper describes an inversion scheme based on a radiance Monte Carlo model and an adjoint-assisted gradient optimization that incorporates fluence-dependent step sizes and adaptive moment estimation. The inversion is shown to recover absolute chromophore concentrations, blood oxygen saturation and the Grüneisen parameter from in silico 3D phantom images for different radiance approximations. The scattering coefficient was assumed to be homogeneous and known a priori. Y1 - 2019 U6 - https://doi.org/10.1117/1.JBO.24.6.066001 VL - 24 IS - 6 SP - 066001 ER - TY - GEN A1 - Buchmann, Jens A1 - Kaplan, Bernhard A1 - Powell, Samuel A1 - Prohaska, Steffen A1 - Laufer, Jan T1 - 3D quantitative photoacoustic tomography using an adjoint radiance Monte Carlo model and gradient descent N2 - Quantitative photoacoustic tomography aims to recover maps of the local concentrations of tissue chromophores from multispectral images. While model-based inversion schemes are promising approaches, major challenges to their practical implementation include the unknown fluence distribution and the scale of the inverse problem. This paper describes an inversion scheme based on a radiance Monte Carlo model and an adjoint-assisted gradient optimization that incorporates fluence-dependent step sizes and adaptive moment estimation. The inversion is shown to recover absolute chromophore concentrations, blood oxygen saturation and the Grüneisen parameter from in silico 3D phantom images for different radiance approximations. The scattering coefficient was assumed to be homogeneous and known a priori. T3 - ZIB-Report - 19-16 KW - quantitative photoacoustic imaging KW - blood oxygen saturation KW - inverse problem KW - model-based inversion KW - Monte Carlo KW - spectral unmixing Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-72995 SN - 1438-0064 ER - TY - GEN A1 - Buchmann, Jens A1 - Kaplan, Bernhard A1 - Powell, Samuel A1 - Prohaska, Steffen A1 - Laufer, Jan T1 - Quantitative PA tomography of high resolution 3-D images: experimental validation in tissue phantoms N2 - Quantitative photoacoustic tomography aims recover the spatial distribution of absolute chromophore concentrations and their ratios from deep tissue, high-resolution images. In this study, a model-based inversion scheme based on a Monte-Carlo light transport model is experimentally validated on 3-D multispectral images of a tissue phantom acquired using an all-optical scanner with a planar detection geometry. A calibrated absorber allowed scaling of the measured data during the inversion, while an acoustic correction method was employed to compensate the effects of limited view detection. Chromophore- and fluence-dependent step sizes and Adam optimization were implemented to achieve rapid convergence. High resolution 3-D maps of absolute concentrations and their ratios were recovered with high accuracy. Potential applications of this method include quantitative functional and molecular photoacoustic tomography of deep tissue in preclinical and clinical studies. T3 - ZIB-Report - 19-60 KW - quantitative photoacoustic imaging KW - blood oxygen saturation KW - inverse problem KW - model-based inversion KW - Monte Carlo KW - spectral unmixing Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-75416 SN - 1438-0064 ER -