TY - JOUR A1 - Deuflhard, Peter A1 - Weiser, Martin A1 - Seebaß, Martin T1 - A New Nonlinear Elliptic Multilevel FEM Applied to Regional Hyperthermia JF - Comput. Visual. Sci. Y1 - 2000 U6 - https://doi.org/10.1007/PL00013546 VL - 3 SP - 1 EP - 6 ER - TY - GEN A1 - Günther, Andreas A1 - Lamecker, Hans A1 - Weiser, Martin T1 - Direct LDDMM of Discrete Currents with Adaptive Finite Elements N2 - We consider Large Deformation Diffeomorphic Metric Mapping of general $m$-currents. After stating an optimization algorithm in the function space of admissable morph generating velocity fields, two innovative aspects in this framework are presented and numerically investigated: First, we spatially discretize the velocity field with conforming adaptive finite elements and discuss advantages of this new approach. Second, we directly compute the temporal evolution of discrete $m$-current attributes. T3 - ZIB-Report - 11-22 KW - Large Deformation KW - Diffeomorphic Registration KW - Matching KW - Currents KW - Adaptive Finite Elements Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-13090 ER - TY - CHAP A1 - Zachow, Stefan A1 - Weiser, Martin A1 - Deuflhard, Peter ED - Niederlag, Wolfgang ED - Lemke, Heinz ED - Meixensberger, Jürgen ED - Baumann, Michael T1 - Modellgestützte Operationsplanung in der Kopfchirurgie T2 - Modellgestützte Therapie Y1 - 2008 SP - 140 EP - 156 PB - Health Academy ER - TY - GEN A1 - Günther, Andreas A1 - Lamecker, Hans A1 - Weiser, Martin ED - Pennec, X. ED - Joshi, S. ED - Nielsen, M. T1 - Direct LDDMM of Discrete Currents with Adaptive Finite Elements T2 - Proceedings of the Third International Workshop on Mathematical Foundations of Computational Anatomy - Geometrical and Statistical Methods for Modelling Biological Shape Variability N2 - We consider Large Deformation Diffeomorphic Metric Mapping of general $m$-currents. After stating an optimization algorithm in the function space of admissable morph generating velocity fields, two innovative aspects in this framework are presented and numerically investigated: First, we spatially discretize the velocity field with conforming adaptive finite elements and discuss advantages of this new approach. Second, we directly compute the temporal evolution of discrete $m$-current attributes. Y1 - 2011 SP - 1 EP - 14 ER - TY - GEN A1 - Weiser, Martin A1 - Erdmann, Bodo A1 - Schenkl, Sebastian A1 - Muggenthaler, Holger A1 - Hubig, Michael A1 - Mall, Gita A1 - Zachow, Stefan T1 - Uncertainty in Temperature-Based Determination of Time of Death N2 - Temperature-based estimation of time of death (ToD) can be per- formed either with the help of simple phenomenological models of corpse cooling or with detailed mechanistic (thermodynamic) heat transfer mod- els. The latter are much more complex, but allow a higher accuracy of ToD estimation as in principle all relevant cooling mechanisms can be taken into account. The potentially higher accuracy depends on the accuracy of tissue and environmental parameters as well as on the geometric resolution. We in- vestigate the impact of parameter variations and geometry representation on the estimated ToD based on a highly detailed 3D corpse model, that has been segmented and geometrically reconstructed from a computed to- mography (CT) data set, differentiating various organs and tissue types. From that we identify the most crucial parameters to measure or estimate, and obtain a local uncertainty quantifcation for the ToD. T3 - ZIB-Report - 17-18 KW - forensic medicine KW - determination of time of death KW - heat transfer equation KW - sensitivity i.r.t. thermal parameters KW - sensitivity i.r.t. geometric resolution Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-63818 SN - 1438-0064 ER - TY - JOUR A1 - Weiser, Martin A1 - Erdmann, Bodo A1 - Schenkl, Sebastian A1 - Muggenthaler, Holger A1 - Hubig, Michael A1 - Mall, Gita A1 - Zachow, Stefan T1 - Uncertainty in Temperature-Based Determination of Time of Death JF - Heat and Mass Transfer N2 - Temperature-based estimation of time of death (ToD) can be per- formed either with the help of simple phenomenological models of corpse cooling or with detailed mechanistic (thermodynamic) heat transfer mod- els. The latter are much more complex, but allow a higher accuracy of ToD estimation as in principle all relevant cooling mechanisms can be taken into account. The potentially higher accuracy depends on the accuracy of tissue and environmental parameters as well as on the geometric resolution. We in- vestigate the impact of parameter variations and geometry representation on the estimated ToD based on a highly detailed 3D corpse model, that has been segmented and geometrically reconstructed from a computed to- mography (CT) data set, differentiating various organs and tissue types. Y1 - 2018 U6 - https://doi.org/10.1007/s00231-018-2324-4 VL - 54 IS - 9 SP - 2815 EP - 2826 PB - Springer ER - TY - JOUR A1 - Schenkl, Sebastian A1 - Muggenthaler, Holger A1 - Hubig, Michael A1 - Erdmann, Bodo A1 - Weiser, Martin A1 - Zachow, Stefan A1 - Heinrich, Andreas A1 - Güttler, Felix Victor A1 - Teichgräber, Ulf A1 - Mall, Gita T1 - Automatic CT-based finite element model generation for temperature-based death time estimation: feasibility study and sensitivity analysis JF - International Journal of Legal Medicine N2 - Temperature based death time estimation is based either on simple phenomenological models of corpse cooling or on detailed physical heat transfer models. The latter are much more complex, but allow a higher accuracy of death time estimation as in principle all relevant cooling mechanisms can be taken into account. Here, a complete work flow for finite element based cooling simulation models is presented. The following steps are demonstrated on CT-phantoms: • CT-scan • Segmentation of the CT images for thermodynamically relevant features of individual geometries • Conversion of the segmentation result into a Finite Element (FE) simulation model • Computation of the model cooling curve • Calculation of the cooling time For the first time in FE-based cooling time estimation the steps from the CT image over segmentation to FE model generation are semi-automatically performed. The cooling time calculation results are compared to cooling measurements performed on the phantoms under controlled conditions. In this context, the method is validated using different CTphantoms. Some of the CT phantoms thermodynamic material parameters had to be experimentally determined via independent experiments. Moreover the impact of geometry and material parameter uncertainties on the estimated cooling time is investigated by a sensitivity analysis. KW - temperature based death time estimation KW - finite element method KW - CT segmentation KW - sensitivity analysis Y1 - 2017 U6 - https://doi.org/doi:10.1007/s00414-016-1523-0 VL - 131 IS - 3 SP - 699 EP - 712 ER - TY - JOUR A1 - Weiser, Martin A1 - Zachow, Stefan A1 - Deuflhard, Peter T1 - Craniofacial Surgery Planning Based on Virtual Patient Models JF - it - Information Technology Y1 - 2010 U6 - https://doi.org/10.1524/itit.2010.0600 VL - 52 IS - 5 SP - 258 EP - 263 PB - Oldenbourg Verlagsgruppe ER -