TY - JOUR A1 - Hochfeld, Mascha A1 - Lamecker, Hans A1 - Thomale, Ulrich W. A1 - Schulz, Matthias A1 - Zachow, Stefan A1 - Haberl, Hannes T1 - Frame-based cranial reconstruction JF - Journal of Neurosurgery: Pediatrics N2 - The authors report on the first experiences with the prototype of a surgical tool for cranial remodeling. The device enables the surgeon to transfer statistical information, represented in a model, into the disfigured bone. The model is derived from a currently evolving databank of normal head shapes. Ultimately, the databank will provide a set of standard models covering the statistical range of normal head shapes, thus providing the required template for any standard remodeling procedure as well as customized models for intended overcorrection. To date, this technique has been used in the surgical treatment of 14 infants (age range 6-12 months) with craniosynostosis. In all 14 cases, the designated esthetic result, embodied by the selected model, has been achieved, without morbidity or mortality. Frame-based reconstruction provides the required tools to precisely realize the surgical reproduction of the model shape. It enables the establishment of a self-referring system, feeding back postoperative growth patterns, recorded by 3D follow-up, into the model design. Y1 - 2014 U6 - https://doi.org/10.3171/2013.11.PEDS1369 VL - 13 IS - 3 SP - 319 EP - 323 ER - TY - CHAP A1 - Mukhopadhyay, Anirban A1 - Morillo, Oscar A1 - Zachow, Stefan A1 - Lamecker, Hans T1 - Robust and Accurate Appearance Models Based on Joint Dictionary Learning Data from the Osteoarthritis Initiative T2 - Lecture Notes in Computer Science, Patch-Based Techniques in Medical Imaging. Patch-MI 2016 N2 - Deformable model-based approaches to 3D image segmentation have been shown to be highly successful. Such methodology requires an appearance model that drives the deformation of a geometric model to the image data. Appearance models are usually either created heuristically or through supervised learning. Heuristic methods have been shown to work effectively in many applications but are hard to transfer from one application (imaging modality/anatomical structure) to another. On the contrary, supervised learning approaches can learn patterns from a collection of annotated training data. In this work, we show that the supervised joint dictionary learning technique is capable of overcoming the traditional drawbacks of the heuristic approaches. Our evaluation based on two different applications (liver/CT and knee/MR) reveals that our approach generates appearance models, which can be used effectively and efficiently in a deformable model-based segmentation framework. Y1 - 2016 U6 - https://doi.org/10.1007/978-3-319-47118-1_4 VL - 9993 SP - 25 EP - 33 ER - TY - JOUR A1 - Wilson, David A1 - Anglin, Carolyn A1 - Ambellan, Felix A1 - Grewe, Carl Martin A1 - Tack, Alexander A1 - Lamecker, Hans A1 - Dunbar, Michael A1 - Zachow, Stefan T1 - Validation of three-dimensional models of the distal femur created from surgical navigation point cloud data for intraoperative and postoperative analysis of total knee arthroplasty JF - International Journal of Computer Assisted Radiology and Surgery N2 - Purpose: Despite the success of total knee arthroplasty there continues to be a significant proportion of patients who are dissatisfied. One explanation may be a shape mismatch between pre and post-operative distal femurs. The purpose of this study was to investigate a method to match a statistical shape model (SSM) to intra-operatively acquired point cloud data from a surgical navigation system, and to validate it against the pre-operative magnetic resonance imaging (MRI) data from the same patients. Methods: A total of 10 patients who underwent navigated total knee arthroplasty also had an MRI scan less than 2 months pre-operatively. The standard surgical protocol was followed which included partial digitization of the distal femur. Two different methods were employed to fit the SSM to the digitized point cloud data, based on (1) Iterative Closest Points (ICP) and (2) Gaussian Mixture Models (GMM). The available MRI data were manually segmented and the reconstructed three-dimensional surfaces used as ground truth against which the statistical shape model fit was compared. Results: For both approaches, the difference between the statistical shape model-generated femur and the surface generated from MRI segmentation averaged less than 1.7 mm, with maximum errors occurring in less clinically important areas. Conclusion: The results demonstrated good correspondence with the distal femoral morphology even in cases of sparse data sets. Application of this technique will allow for measurement of mismatch between pre and post-operative femurs retrospectively on any case done using the surgical navigation system and could be integrated into the surgical navigation unit to provide real-time feedback. Y1 - 2017 UR - https://link.springer.com/content/pdf/10.1007%2Fs11548-017-1630-5.pdf U6 - https://doi.org/10.1007/s11548-017-1630-5 VL - 12 IS - 12 SP - 2097 EP - 2105 PB - Springer ER - TY - GEN A1 - Ehlke, Moritz A1 - Frenzel, Thomas A1 - Ramm, Heiko A1 - Lamecker, Hans A1 - Akbari Shandiz, Mohsen A1 - Anglin, Carolyn A1 - Zachow, Stefan T1 - Robust Measurement of Natural Acetabular Orientation from AP Radiographs using Articulated 3D Shape and Intensity Models T3 - ZIB-Report - 14-12 KW - articulated shape and intensity models KW - 3D reconstruction KW - acetabular orientation KW - image registration Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-49824 SN - 1438-0064 ER - TY - CHAP A1 - Lamecker, Hans A1 - Zachow, Stefan T1 - Statistical Shape Modeling of Musculoskeletal Structures and Its Applications T2 - Computational Radiology for Orthopaedic Interventions N2 - Statistical shape models (SSM) describe the shape variability contained in a given population. They are able to describe large populations of complex shapes with few degrees of freedom. This makes them a useful tool for a variety of tasks that arise in computer-aided madicine. In this chapter we are going to explain the basic methodology of SSMs and present a variety of examples, where SSMs have been successfully applied. Y1 - 2016 SN - 978-3-319-23481-6 U6 - https://doi.org/10.1007/978-3-319-23482-3 VL - 23 SP - 1 EP - 23 PB - Springer ER - TY - JOUR A1 - Günther, Andreas A1 - Lamecker, Hans A1 - Weiser, Martin T1 - Flexible Shape Matching with Finite Element Based LDDMM JF - International Journal of Computer Vision N2 - We consider Large Deformation Diffeomorphic Metric Mapping of general $m$-currents. After stating an optimization algorithm in the function space of admissable morph generating velocity fields, two innovative aspects in this framework are presented and numerically investigated: First, we spatially discretize the velocity field with conforming adaptive finite elements and discuss advantages of this new approach. Second, we directly compute the temporal evolution of discrete $m$-current attributes. Y1 - 2013 U6 - https://doi.org/10.1007/s11263-012-0599-3 VL - 105 IS - 2 SP - 128 EP - 143 ER - TY - GEN A1 - Günther, Andreas A1 - Lamecker, Hans A1 - Weiser, Martin ED - Pennec, X. ED - Joshi, S. ED - Nielsen, M. T1 - Direct LDDMM of Discrete Currents with Adaptive Finite Elements T2 - Proceedings of the Third International Workshop on Mathematical Foundations of Computational Anatomy - Geometrical and Statistical Methods for Modelling Biological Shape Variability N2 - We consider Large Deformation Diffeomorphic Metric Mapping of general $m$-currents. After stating an optimization algorithm in the function space of admissable morph generating velocity fields, two innovative aspects in this framework are presented and numerically investigated: First, we spatially discretize the velocity field with conforming adaptive finite elements and discuss advantages of this new approach. Second, we directly compute the temporal evolution of discrete $m$-current attributes. Y1 - 2011 SP - 1 EP - 14 ER - TY - JOUR A1 - Li, Jianning A1 - Pimentel, Pedro A1 - Szengel, Angelika A1 - Ehlke, Moritz A1 - Lamecker, Hans A1 - Zachow, Stefan A1 - Estacio, Laura A1 - Doenitz, Christian A1 - Ramm, Heiko A1 - Shi, Haochen A1 - Chen, Xiaojun A1 - Matzkin, Franco A1 - Newcombe, Virginia A1 - Ferrante, Enzo A1 - Jin, Yuan A1 - Ellis, David G. A1 - Aizenberg, Michele R. A1 - Kodym, Oldrich A1 - Spanel, Michal A1 - Herout, Adam A1 - Mainprize, James G. A1 - Fishman, Zachary A1 - Hardisty, Michael R. A1 - Bayat, Amirhossein A1 - Shit, Suprosanna A1 - Wang, Bomin A1 - Liu, Zhi A1 - Eder, Matthias A1 - Pepe, Antonio A1 - Gsaxner, Christina A1 - Alves, Victor A1 - Zefferer, Ulrike A1 - von Campe, Cord A1 - Pistracher, Karin A1 - Schäfer, Ute A1 - Schmalstieg, Dieter A1 - Menze, Bjoern H. A1 - Glocker, Ben A1 - Egger, Jan T1 - AutoImplant 2020 - First MICCAI Challenge on Automatic Cranial Implant Design JF - IEEE Transactions on Medical Imaging N2 - The aim of this paper is to provide a comprehensive overview of the MICCAI 2020 AutoImplant Challenge. The approaches and publications submitted and accepted within the challenge will be summarized and reported, highlighting common algorithmic trends and algorithmic diversity. Furthermore, the evaluation results will be presented, compared and discussed in regard to the challenge aim: seeking for low cost, fast and fully automated solutions for cranial implant design. Based on feedback from collaborating neurosurgeons, this paper concludes by stating open issues and post-challenge requirements for intra-operative use. Y1 - 2021 U6 - https://doi.org/10.1109/TMI.2021.3077047 SN - 0278-0062 VL - 40 IS - 9 SP - 2329 EP - 2342 ER - TY - JOUR A1 - Xie, Kunpeng A1 - Gruber, Lennart Johannes A1 - Crampen, Martin A1 - Li, Yao A1 - Ferreira, André A1 - Tappeiner, Elias A1 - Gillot, Maxime A1 - Schepers, Jan A1 - Xu, Jiangchang A1 - Pankert, Tobias A1 - Beyer, Michel A1 - Shahamiri, Negar A1 - ten Brink, Reinier A1 - Dot, Gauthier A1 - Weschke, Charlotte A1 - van Nistelrooij, Niels A1 - Verhelst, Pieter-Jan A1 - Guo, Yan A1 - Xu, Zhibin A1 - Bienzeisler, Jonas A1 - Rashad, Ashkan A1 - Flügge, Tabea A1 - Cotton, Ross A1 - Vinayahalingam, Shankeeth A1 - Ilesan, Robert A1 - Raith, Stefan A1 - Madsen, Dennis A1 - Seibold, Constantin A1 - Xi, Tong A1 - Bergé, Stefaan A1 - Nebelung, Sven A1 - Kodym, Oldřich A1 - Sundqvist, Osku A1 - Thieringer, Florian A1 - Lamecker, Hans A1 - Coppens, Antoine A1 - Potrusil, Thomas A1 - Kraeima, Joep A1 - Witjes, Max A1 - Wu, Guomin A1 - Chen, Xiaojun A1 - Lambrechts, Adriaan A1 - Cevidanes, Lucia H Soares A1 - Zachow, Stefan A1 - Hermans, Alexander A1 - Truhn, Daniel A1 - Alves, Victor A1 - Egger, Jan A1 - Röhrig, Rainer A1 - Hölzle, Frank A1 - Puladi, Behrus T1 - Beyond Benchmarks: Towards Robust Artificial Intelligence Bone Segmentation in Socio-Technical Systems JF - Expert Systems With Applications N2 - Despite the advances in automated medical image segmentation, AI models still underperform in various clinical settings, challenging real-world integration. In this multicenter evaluation, we analyzed 20 state-of-the-art mandibular segmentation models across 19,218 segmentations of 1,000 clinically resampled CT/CBCT scans. We show that segmentation accuracy varies by up to 25% depending on socio-technical factors such as voxel size, bone orientation, and patient conditions such as osteosynthesis or pathology. Higher sharpness, isotropic smaller voxels, and neutral orientation significantly improved results, while metallic osteosynthesis and anatomical complexity led to significant degradation. Our findings challenge the common view of AI models as “plug-and-play” tools and suggest evidence-based optimization recommendations for both clinicians and developers. This will in turn boost the integration of AI segmentation tools in routine healthcare. Y1 - 2025 UR - https://www.medrxiv.org/content/10.1101/2025.06.11.25329022v1 U6 - https://doi.org/10.1016/j.eswa.2025.130031 VL - 299 IS - Part D ER -