TY - JOUR A1 - Todt, Ingo A1 - Lamecker, Hans A1 - Ramm, Heiko A1 - Ernst, Arneborg T1 - A computed tomographic data-based vibrant bonebridge visualization tool JF - Cochlear Implants International N2 - Information about the temporal bone size and variations of anatomical structures are crucial for a safe positioning of the Vibrant Bonebridge B-FMT. A radiological based preoperative planning of the surgical procedure decreases the surgical time and minimizes the risk of complications. We developed a software tool, which allows a catch up of foreign DICOM data based CT temporal bone scans. The individual CT scan is transmitted into a 3D reconstructed pattern of the temporal bone. In this 3D reconstruction the individually favored position of the B- FMT should be found. The software allows a determination of a safe B-FMT position by identifying the individual relation of middle fossa, jugular bulb and external auditory canal. Skull thickness and screw length are contained parameters for the surgical planning. An easy to handle software tool allows a radiologically data based safe and fast surgical positioning of the B-FMT. Y1 - 2014 U6 - https://doi.org/10.1179/1467010014Z.000000000155 VL - 15 IS - S1 SP - 72 EP - 74 ER - TY - JOUR A1 - Galloway, Francis A1 - Kahnt, Max A1 - Ramm, Heiko A1 - Worsley, Peter A1 - Zachow, Stefan A1 - Nair, Prasanth A1 - Taylor, Mark T1 - A large scale finite element study of a cementless osseointegrated tibial tray JF - Journal of Biomechanics Y1 - 2013 U6 - https://doi.org//10.1016/j.jbiomech.2013.04.021 VL - 46 IS - 11 SP - 1900 EP - 1906 ER - TY - GEN A1 - Bindernagel, Matthias A1 - Kainmüller, Dagmar A1 - Ramm, Heiko A1 - Lamecker, Hans A1 - Zachow, Stefan T1 - Analysis of inter-individual anatomical shape variations of joint structures T2 - Proc. Int. Society of Computer Assisted Orthopaedic Surgery (CAOS) Y1 - 2012 IS - 210 ER - TY - JOUR A1 - Li, Jianning A1 - Pimentel, Pedro A1 - Szengel, Angelika A1 - Ehlke, Moritz A1 - Lamecker, Hans A1 - Zachow, Stefan A1 - Estacio, Laura A1 - Doenitz, Christian A1 - Ramm, Heiko A1 - Shi, Haochen A1 - Chen, Xiaojun A1 - Matzkin, Franco A1 - Newcombe, Virginia A1 - Ferrante, Enzo A1 - Jin, Yuan A1 - Ellis, David G. A1 - Aizenberg, Michele R. A1 - Kodym, Oldrich A1 - Spanel, Michal A1 - Herout, Adam A1 - Mainprize, James G. A1 - Fishman, Zachary A1 - Hardisty, Michael R. A1 - Bayat, Amirhossein A1 - Shit, Suprosanna A1 - Wang, Bomin A1 - Liu, Zhi A1 - Eder, Matthias A1 - Pepe, Antonio A1 - Gsaxner, Christina A1 - Alves, Victor A1 - Zefferer, Ulrike A1 - von Campe, Cord A1 - Pistracher, Karin A1 - Schäfer, Ute A1 - Schmalstieg, Dieter A1 - Menze, Bjoern H. A1 - Glocker, Ben A1 - Egger, Jan T1 - AutoImplant 2020 - First MICCAI Challenge on Automatic Cranial Implant Design JF - IEEE Transactions on Medical Imaging N2 - The aim of this paper is to provide a comprehensive overview of the MICCAI 2020 AutoImplant Challenge. The approaches and publications submitted and accepted within the challenge will be summarized and reported, highlighting common algorithmic trends and algorithmic diversity. Furthermore, the evaluation results will be presented, compared and discussed in regard to the challenge aim: seeking for low cost, fast and fully automated solutions for cranial implant design. Based on feedback from collaborating neurosurgeons, this paper concludes by stating open issues and post-challenge requirements for intra-operative use. Y1 - 2021 U6 - https://doi.org/10.1109/TMI.2021.3077047 SN - 0278-0062 VL - 40 IS - 9 SP - 2329 EP - 2342 ER - TY - JOUR A1 - Pimentel, Pedro A1 - Szengel, Angelika A1 - Ehlke, Moritz A1 - Lamecker, Hans A1 - Zachow, Stefan A1 - Estacio, Laura A1 - Doenitz, Christian A1 - Ramm, Heiko ED - Li, Jianning ED - Egger, Jan T1 - Automated Virtual Reconstruction of Large Skull Defects using Statistical Shape Models and Generative Adversarial Networks BT - First Challenge, AutoImplant 2020, Held in Conjunction with MICCAI 2020, Lima, Peru, October 8, 2020, Proceedings JF - Towards the Automatization of Cranial Implant Design in Cranioplasty N2 - We present an automated method for extrapolating missing regions in label data of the skull in an anatomically plausible manner. The ultimate goal is to design patient-speci� c cranial implants for correcting large, arbitrarily shaped defects of the skull that can, for example, result from trauma of the head. Our approach utilizes a 3D statistical shape model (SSM) of the skull and a 2D generative adversarial network (GAN) that is trained in an unsupervised fashion from samples of healthy patients alone. By � tting the SSM to given input labels containing the skull defect, a First approximation of the healthy state of the patient is obtained. The GAN is then applied to further correct and smooth the output of the SSM in an anatomically plausible manner. Finally, the defect region is extracted using morphological operations and subtraction between the extrapolated healthy state of the patient and the defective input labels. The method is trained and evaluated based on data from the MICCAI 2020 AutoImplant challenge. It produces state-of-the art results on regularly shaped cut-outs that were present in the training and testing data of the challenge. Furthermore, due to unsupervised nature of the approach, the method generalizes well to previously unseen defects of varying shapes that were only present in the hidden test dataset. Y1 - 2020 U6 - https://doi.org/10.1007/978-3-030-64327-0_3 N1 - Best Paper Award VL - 12439 SP - 16 EP - 27 PB - Springer International Publishing ET - 1 ER - TY - JOUR A1 - Akbari Shandiz, Mohsen A1 - Boulos, Paul A1 - Sævarsson, Stefan A1 - Ramm, Heiko A1 - Fu, Chun Kit A1 - Miller, Stephen A1 - Zachow, Stefan A1 - Anglin, Carolyn T1 - Changes in Knee Shape and Geometry Resulting from Total Knee Arthroplasty JF - Journal of Engineering in Medicine N2 - Changes in knee shape and geometry resulting from total knee arthroplasty can affect patients in numerous important ways: pain, function, stability, range of motion, and kinematics. Quantitative data concerning these changes have not been previously available, to our knowledge, yet are essential to understand individual experiences of total knee arthroplasty and thereby improve outcomes for all patients. The limiting factor has been the challenge of accurately measuring these changes. Our study objective was to develop a conceptual framework and analysis method to investigate changes in knee shape and geometry, and prospectively apply it to a sample total knee arthroplasty population. Using clinically available computed tomography and radiography imaging systems, the three-dimensional knee shape and geometry of nine patients (eight varus and one valgus) were compared before and after total knee arthroplasty. All patients had largely good outcomes after their total knee arthroplasty. Knee shape changed both visually and numerically. On average, the distal condyles were slightly higher medially and lower laterally (range: +4.5 mm to −4.4 mm), the posterior condyles extended farther out medially but not laterally (range: +1.8 to −6.4 mm), patellofemoral distance increased throughout flexion by 1.8–3.5 mm, and patellar thickness alone increased by 2.9 mm (range: 0.7–5.2 mm). External femoral rotation differed preop and postop. Joint line distance, taking cartilage into account, changed by +0.7 to −1.5 mm on average throughout flexion. Important differences in shape and geometry were seen between pre-total knee arthroplasty and post-total knee arthroplasty knees. While this is qualitatively known, this is the first study to report it quantitatively, an important precursor to identifying the reasons for the poor outcome of some patients. Using the developed protocol and visualization techniques to compare patients with good versus poor clinical outcomes could lead to changes in implant design, implant selection, component positioning, and surgical technique. Recommendations based on this sample population are provided. Intraoperative and postoperative feedback could ultimately improve patient satisfaction. Y1 - 2018 UR - http://journals.sagepub.com/eprint/ZVgNrNESA9EjIcaFWSjb/full U6 - https://doi.org/10.1177/0954411917743274 VL - 232 IS - 1 SP - 67 EP - 79 ER - TY - JOUR A1 - Brüning, Jan A1 - Hildebrandt, Thomas A1 - Heppt, Werner A1 - Schmidt, Nora A1 - Lamecker, Hans A1 - Szengel, Angelika A1 - Amiridze, Natalja A1 - Ramm, Heiko A1 - Bindernagel, Matthias A1 - Zachow, Stefan A1 - Goubergrits, Leonid T1 - Characterization of the Airflow within an Average Geometry of the Healthy Human Nasal Cavity JF - Scientific Reports N2 - This study’s objective was the generation of a standardized geometry of the healthy nasal cavity. An average geometry of the healthy nasal cavity was generated using a statistical shape model based on 25 symptom-free subjects. Airflow within the average geometry and these geometries was calculated using fluid simulations. Integral measures of the nasal resistance, wall shear stresses (WSS) and velocities were calculated as well as cross-sectional areas (CSA). Furthermore, individual WSS and static pressure distributions were mapped onto the average geometry. The average geometry featured an overall more regular shape that resulted in less resistance, reduced wall shear stresses and velocities compared to the median of the 25 geometries. Spatial distributions of WSS and pressure of average geometry agreed well compared to the average distributions of all individual geometries. The minimal CSA of the average geometry was larger than the median of all individual geometries (83.4 vs. 74.7 mm²). The airflow observed within the average geometry of the healthy nasal cavity did not equal the average airflow of the individual geometries. While differences observed for integral measures were notable, the calculated values for the average geometry lay within the distributions of the individual parameters. Spatially resolved parameters differed less prominently. Y1 - 2020 UR - https://rdcu.be/b2irD U6 - https://doi.org/10.1038/s41598-020-60755-3 VL - 3755 IS - 10 ER - TY - JOUR A1 - Ho, Karen A1 - Saevarsson, Stefan A1 - Ramm, Heiko A1 - Lieck, Robert A1 - Zachow, Stefan A1 - Sharma, Gulshan A1 - Rex, Erica A1 - Amiri, Shahram A1 - Wu, Barnabas A1 - Leumann, Andre A1 - Anglin, Carolyn T1 - Computed tomography analysis of knee pose and geometry before and after total knee arthroplasty JF - Journal of biomechanics Y1 - 2012 UR - http://www.ncbi.nlm.nih.gov/pubmed/22796002 U6 - https://doi.org/10.1016/j.jbiomech.2012.06.004 VL - 45 IS - 13 SP - 2215 EP - 21 ER - TY - CHAP A1 - Ramm, Heiko A1 - Zachow, Stefan ED - Niederlag, Wolfgang ED - Lemke, Heinz ED - Peitgen, Heinz-Otto ED - Lehrach, Hans T1 - Computergestützte Planung für die individuelle Implantatversorgung T2 - Health Academy Y1 - 2012 VL - 16 SP - 145 EP - 158 ER - TY - GEN A1 - Ehlke, Moritz A1 - Ramm, Heiko A1 - Lamecker, Hans A1 - Zachow, Stefan T1 - Efficient projection and deformation of volumetric intensity models for accurate simulation of X-ray images N2 - We present an efficient GPU-based method to generate virtual X-ray images from tetrahedral meshes which are associated with attenuation values. In addition, a novel approach is proposed that performs the model deformation on the GPU. The tetrahedral grids are derived from volumetric statistical shape and intensity models (SSIMs) and describe anatomical structures. Our research targets at reconstructing 3D anatomical shapes by comparing virtual X-ray images generated using our novel approach with clinical data while varying the shape and density of the SSIM in an optimization process. We assume that a deformed SSIM adequately represents an anatomy of interest when the similarity between the virtual and the clinical X-ray image is maximized. The OpenGL implementation presented here generates accurate (virtual) X-ray images at interactive rates, thus qualifying it for its use in the reconstruction process. T3 - ZIB-Report - 12-40 KW - Digitally Reconstructed Radiograph (DRR), Anatomy Reconstruction, Statistical Shape and Intensity Model (SSIM), GPU acceleration Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-16580 SN - 1438-0064 ER -