TY - JOUR A1 - Thomsen, Jesper A1 - Laib, Andreas A1 - Koller, Bruno A1 - Prohaska, Steffen A1 - Mosekilde, L. A1 - Gowin, Wolfgang T1 - Stereological measures of trabecular bone structure: Comparison of 3D micro computed tomography with 2D histological sections in human proximal tibial bone biopsies JF - Journal of Microscopy Y1 - 2005 VL - 218 SP - 171 EP - 179 ER - TY - CHAP A1 - Prohaska, Steffen A1 - Hutanu, Andrei T1 - Remote data access for interactive visualization T2 - 13th Annual Mardi Gras Conference: Frontiers of Grid Applications and Technologies Y1 - 2005 SP - 17 EP - 22 ER - TY - JOUR A1 - Fouard, Céline A1 - Malandain, Grégoire A1 - Prohaska, Steffen A1 - Westerhoff, Malte T1 - Blockwise processing applied to brain micro-vascular network study JF - IEEE Transactions on Medical Imaging Y1 - 2006 U6 - https://doi.org/10.1109/TMI.2006.880670 VL - 25 IS - 10 SP - 1319 EP - 1328 ER - TY - JOUR A1 - Zaikin, Alexei A1 - Saparin, Peter A1 - Kurths, Jürgen A1 - Prohaska, Steffen A1 - Gowin, Wolfgang T1 - Modeling resorption in 2D-CT and 3D μ-CT bone images JF - Int. J. of Bif. and Chaos Y1 - 2005 VL - 15(9) SP - 2995 EP - 3009 ER - TY - JOUR A1 - Weber, Britta A1 - Tranfield, Erin M. A1 - Höög, Johanna L. A1 - Baum, Daniel A1 - Antony, Claude A1 - Hyman, Tony A1 - Verbavatz, Jean-Marc A1 - Prohaska, Steffen T1 - Automated stitching of microtubule centerlines across serial electron tomograms JF - PLoS ONE Y1 - 2014 U6 - https://doi.org/10.1371/journal.pone.0113222 SP - e113222 ER - TY - GEN A1 - Redemann, Stefanie A1 - Weber, Britta A1 - Möller, Marit A1 - Verbavatz, Jean-Marc A1 - Hyman, Anthony A1 - Baum, Daniel A1 - Prohaska, Steffen A1 - Müller-Reichert, Thomas T1 - The Segmentation of Microtubules in Electron Tomograms Using Amira T2 - Mitosis: Methods and Protocols Y1 - 2014 U6 - https://doi.org/10.1007/978-1-4939-0329-0_12 SP - 261 EP - 278 PB - Springer ER - TY - GEN A1 - Costa, Marta A1 - Ostrovsky, Aaron D. A1 - Manton, James D. A1 - Prohaska, Steffen A1 - Jefferis, Gregory S.X.E. T1 - NBLAST: Rapid, sensitive comparison of neuronal structure and construction of neuron family databases T2 - bioRxiv preprint Y1 - 2015 U6 - https://doi.org/10.1101/006346 ER - TY - GEN A1 - Hoerth, Rebecca M. A1 - Baum, Daniel A1 - Knötel, David A1 - Prohaska, Steffen A1 - Willie, Bettina M. A1 - Duda, Georg A1 - Hege, Hans-Christian A1 - Fratzl, Peter A1 - Wagermaier, Wolfgang T1 - Registering 2D and 3D Imaging Data of Bone during Healing N2 - Purpose/Aims of the Study: Bone’s hierarchical structure can be visualized using a variety of methods. Many techniques, such as light and electron microscopy generate two-dimensional (2D) images, while micro computed tomography (μCT) allows a direct representation of the three-dimensional (3D) structure. In addition, different methods provide complementary structural information, such as the arrangement of organic or inorganic compounds. The overall aim of the present study is to answer bone research questions by linking information of different 2D and 3D imaging techniques. A great challenge in combining different methods arises from the fact that they usually reflect different characteristics of the real structure. Materials and Methods: We investigated bone during healing by means of μCT and a couple of 2D methods. Backscattered electron images were used to qualitatively evaluate the tissue’s calcium content and served as a position map for other experimental data. Nanoindentation and X-ray scattering experiments were performed to visualize mechanical and structural properties. Results: We present an approach for the registration of 2D data in a 3D μCT reference frame, where scanning electron microscopies serve as a methodic link. Backscattered electron images are perfectly suited for registration into μCT reference frames, since both show structures based on the same physical principles. We introduce specific registration tools that have been developed to perform the registration process in a semi-automatic way. Conclusions: By applying this routine, we were able to exactly locate structural information (e.g. mineral particle properties) in the 3D bone volume. In bone healing studies this will help to better understand basic formation, remodeling and mineralization processes. T3 - ZIB-Report - 15-01 Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-53426 SN - 1438-0064 ER - TY - JOUR A1 - Hoerth, Rebecca M. A1 - Baum, Daniel A1 - Knötel, David A1 - Prohaska, Steffen A1 - Willie, Bettina M. A1 - Duda, Georg A1 - Hege, Hans-Christian A1 - Fratzl, Peter A1 - Wagermaier, Wolfgang T1 - Registering 2D and 3D Imaging Data of Bone during Healing JF - Connective Tissue Research Y1 - 2015 U6 - https://doi.org/10.3109/03008207.2015.1005210 VL - 56 IS - 2 SP - 133 EP - 143 PB - Taylor & Francis ER - TY - GEN A1 - Weber, Britta A1 - Tranfield, Erin M. A1 - Höög, Johanna L. A1 - Baum, Daniel A1 - Antony, Claude A1 - Hyman, Tony A1 - Verbavatz, Jean-Marc A1 - Prohaska, Steffen T1 - Automated stitching of microtubule centerlines across serial electron tomograms N2 - Tracing microtubule centerlines in serial section electron tomography requires microtubules to be stitched across sections, that is lines from different sections need to be aligned, endpoints need to be matched at section boundaries to establish a correspondence between neighboring sections, and corresponding lines need to be connected across multiple sections. We present computational methods for these tasks: 1) An initial alignment is computed using a distance compatibility graph. 2) A fine alignment is then computed with a probabilistic variant of the iterative closest points algorithm, which we extended to handle the orientation of lines by introducing a periodic random variable to the probabilistic formulation. 3) Endpoint correspondence is established by formulating a matching problem in terms of a Markov random field and computing the best matching with belief propagation. Belief propagation is not generally guaranteed to converge to a minimum. We show how convergence can be achieved, nonetheless, with minimal manual input. In addition to stitching microtubule centerlines, the correspondence is also applied to transform and merge the electron tomograms. We applied the proposed methods to samples from the mitotic spindle in C. elegans, the meiotic spindle in X. laevis, and sub-pellicular microtubule arrays in T. brucei. The methods were able to stitch microtubules across section boundaries in good agreement with experts’ opinions for the spindle samples. Results, however, were not satisfactory for the microtubule arrays. For certain experiments, such as an analysis of the spindle, the proposed methods can replace manual expert tracing and thus enable the analysis of microtubules over long distances with reasonable manual effort. T3 - ZIB-Report - 14-41 KW - electron tomography KW - microtubules KW - serial sectioning KW - image analysis KW - geometry reconstruction KW - image and geometry alignment KW - point correspondence Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-52958 SN - 1438-0064 ER - TY - GEN A1 - Kaplan, Bernhard A1 - Laufer, Jan A1 - Prohaska, Steffen A1 - Buchmann, Jens T1 - Monte-Carlo-based inversion scheme for 3D quantitative photoacoustic tomography N2 - The goal of quantitative photoacoustic tomography (qPAT) is to recover maps of the chromophore distributions from multiwavelength images of the initial pressure. Model-based inversions that incorporate the physical processes underlying the photoacoustic (PA) signal generation represent a promising approach. Monte-Carlo models of the light transport are computationally expensive, but provide accurate fluence distributions predictions, especially in the ballistic and quasi-ballistic regimes. Here, we focus on the inverse problem of 3D qPAT of blood oxygenation and investigate the application of the Monte-Carlo method in a model-based inversion scheme. A forward model of the light transport based on the MCX simulator and acoustic propagation modeled by the k-Wave toolbox was used to generate a PA image data set acquired in a tissue phantom over a planar detection geometry. The combination of the optical and acoustic models is shown to account for limited-view artifacts. In addition, the errors in the fluence due to, for example, partial volume artifacts and absorbers immediately adjacent to the region of interest are investigated. To accomplish large-scale inversions in 3D, the number of degrees of freedom is reduced by applying image segmentation to the initial pressure distribution to extract a limited number of regions with homogeneous optical parameters. The absorber concentration in the tissue phantom was estimated using a coordinate descent parameter search based on the comparison between measured and modeled PA spectra. The estimated relative concentrations using this approach lie within 5 % compared to the known concentrations. Finally, we discuss the feasibility of this approach to recover the blood oxygenation from experimental data. T3 - ZIB-Report - 17-04 KW - quantitative photoacoustic tomography KW - model-based inversion KW - oxygen saturation KW - chromophore concentration KW - photoacoustic imaging KW - Monte Carlo methods for light transport KW - boundary conditions KW - coordinate search Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-62318 SN - 1438-0064 ER - TY - CHAP A1 - Kaplan, Bernhard A1 - Buchmann, Jens A1 - Prohaska, Steffen A1 - Laufer, Jan T1 - Monte-Carlo-based inversion scheme for 3D quantitative photoacoustic tomography T2 - Proc. of SPIE, Photons Plus Ultrasound: Imaging and Sensing 2017 N2 - The goal of quantitative photoacoustic tomography (qPAT) is to recover maps of the chromophore distributions from multiwavelength images of the initial pressure. Model-based inversions that incorporate the physical processes underlying the photoacoustic (PA) signal generation represent a promising approach. Monte-Carlo models of the light transport are computationally expensive, but provide accurate fluence distributions predictions, especially in the ballistic and quasi-ballistic regimes. Here, we focus on the inverse problem of 3D qPAT of blood oxygenation and investigate the application of the Monte-Carlo method in a model-based inversion scheme. A forward model of the light transport based on the MCX simulator and acoustic propagation modeled by the k-Wave toolbox was used to generate a PA image data set acquired in a tissue phantom over a planar detection geometry. The combination of the optical and acoustic models is shown to account for limited-view artifacts. In addition, the errors in the fluence due to, for example, partial volume artifacts and absorbers immediately adjacent to the region of interest are investigated. To accomplish large-scale inversions in 3D, the number of degrees of freedom is reduced by applying image segmentation to the initial pressure distribution to extract a limited number of regions with homogeneous optical parameters. The absorber concentration in the tissue phantom was estimated using a coordinate descent parameter search based on the comparison between measured and modeled PA spectra. The estimated relative concentrations using this approach lie within 5 % compared to the known concentrations. Finally, we discuss the feasibility of this approach to recover the blood oxygenation from experimental data. Y1 - 2017 U6 - https://doi.org/10.1117/12.2251945 VL - 10064 SP - 100645J EP - 100645J-13 ER - TY - CHAP A1 - Buchmann, Jens A1 - Kaplan, Bernhard A1 - Prohaska, Steffen A1 - Laufer, Jan T1 - Experimental validation of a Monte-Carlo-based inversion scheme for 3D quantitative photoacoustic tomography T2 - Proc. of SPIE, Photons Plus Ultrasound: Imaging and Sensing N2 - Quantitative photoacoustic tomography (qPAT) aims to extract physiological parameters, such as blood oxygen saturation (sO2), from measured multi-wavelength image data sets. The challenge of this approach lies in the inherently nonlinear fluence distribution in the tissue, which has to be accounted for by using an appropriate model, and the large scale of the inverse problem. In addition, the accuracy of experimental and scanner-specific parameters, such as the wavelength dependence of the incident fluence, the acoustic detector response, the beam profile and divergence, needs to be considered. This study aims at quantitative imaging of blood sO2, as it has been shown to be a more robust parameter compared to absolute concentrations. We propose a Monte-Carlo–based inversion scheme in conjunction with a reduction in the number of variables achieved using image segmentation. The inversion scheme is experimentally validated in tissue-mimicking phantoms consisting of polymer tubes suspended in a scattering liquid. The tubes were filled with chromophore solutions at different concentration ratios. 3-D multi-spectral image data sets were acquired using a Fabry-Perot based PA scanner. A quantitative comparison of the measured data with the output of the forward model is presented. Parameter estimates of chromophore concentration ratios were found to be within 5 % of the true values. Y1 - 2017 U6 - https://doi.org/10.1117/12.2252359 VL - 10064 SP - 1006416 EP - 1006416-8 ER - TY - GEN A1 - Zhukova, Yulia A1 - Hiepen, Christian A1 - Knaus, Petra A1 - Osterland, Marc A1 - Prohaska, Steffen A1 - Dunlop, John W. C. A1 - Fratzl, Peter A1 - Skorb, Ekaterina V. T1 - The role of titanium surface nanotopography on preosteoblast morphology, adhesion and migration N2 - Surface structuring of titanium-based implants with appropriate nanotopographies can significantly modulate their impact on the biological behavior of cells populating these implants. Implant assisted bone tissue repair and regeneration require functional adhesion and expansion of bone progenitors. The surface nanotopography of implant materials used to support bone healing and its effect on cell behavior, in particular cell adhesion, spreading, expansion, and motility, is still not clearly understood. The aim of this study is to investigate preosteoblast proliferation, adhesion, morphology, and migration on different titanium materials with similar surface chemistry, but distinct nanotopographical features. Sonochemical treatment and anodic oxidation were employed to fabricate disordered – mesoporous titania (TMS), and ordered – titania nanotubular (TNT) topographies respectively. The morphological evaluation revealed a surface dependent shape, thickness, and spreading of cells owing to different adherence behavior. Cells were polygonal-shaped and well-spread on glass and TMS, but displayed an elongated fibroblast-like morphology on TNT surfaces. The cells on glass however, were much flatter than on nanostructured surfaces. Both nanostructured surfaces impaired cell adhesion, but TMS was more favorable for cell growth due to its support of cell attachment and spreading in contrast to TNT. Quantitative wound healing assay in combination with live-cell imaging revealed that cells seeded on TMS surfaces migrated in close proximity to neighboring cells and less directed when compared to the migratory behavior on other surfaces. The results indicate distinctly different cell adhesion and migration on ordered and disordered titania nanotopographies, providing important information that could be used in optimizing titanium-based scaffold design to foster bone tissue growth and repair. T3 - ZIB-Report - 17-06 Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-63053 SN - 1438-0064 ER - TY - JOUR A1 - Homberg, Ulrike A1 - Baum, Daniel A1 - Prohaska, Steffen A1 - Günster, Jens A1 - Krauß-Schüler, Stefanie T1 - Adapting trabecular structures for 3D printing: an image processing approach based on µCT data JF - Biomedical Physics & Engineering Express N2 - Materials with a trabecular structure notably combine advantages such as lightweight, reasonable strength, and permeability for fluids. This combination of advantages is especially interesting for tissue engineering in trauma surgery and orthopedics. Bone-substituting scaffolds for instance are designed with a trabecular structure in order to allow cell migration for bone ingrowth and vascularization. An emerging and recently very popular technology to produce such complex, porous structures is 3D printing. However, several technological aspects regarding the scaffold architecture, the printable resolution, and the feature size have to be considered when fabricating scaffolds for bone tissue replacement and regeneration. Here, we present a strategy to assess and prepare realistic trabecular structures for 3D printing using image analysis with the aim of preserving the structural elements. We discuss critical conditions of the printing system and present a 3-stage approach to adapt a trabecular structure from $\mu$CT data while incorporating knowledge about the printing system. In the first stage, an image-based extraction of solid and void structures is performed, which results in voxel- and graph-based representations of the extracted structures. These representations not only allow us to quantify geometrical properties such as pore size or strut geometry and length. But, since the graph represents the geometry and the topology of the initial structure, it can be used in the second stage to modify and adjust feature size, volume and sample size in an easy and consistent way. In the final reconstruction stage, the graph is then converted into a voxel representation preserving the topology of the initial structure. This stage generates a model with respect to the printing conditions to ensure a stable and controlled voxel placement during the printing process. Y1 - 2017 U6 - https://doi.org/10.1088/2057-1976/aa7611 VL - 3 IS - 3 PB - IOP Publishing ER - TY - GEN A1 - Homberg, Ulrike A1 - Baum, Daniel A1 - Prohaska, Steffen A1 - Günster, Jens A1 - Krauß-Schüler, Stefanie T1 - Adapting trabecular structures for 3D printing: an image processing approach based on µCT data N2 - Materials with a trabecular structure notably combine advantages such as lightweight, reasonable strength, and permeability for fluids. This combination of advantages is especially interesting for tissue engineering in trauma surgery and orthopedics. Bone-substituting scaffolds for instance are designed with a trabecular structure in order to allow cell migration for bone ingrowth and vascularization. An emerging and recently very popular technology to produce such complex, porous structures is 3D printing. However, several technological aspects regarding the scaffold architecture, the printable resolution, and the feature size have to be considered when fabricating scaffolds for bone tissue replacement and regeneration. Here, we present a strategy to assess and prepare realistic trabecular structures for 3D printing using image analysis with the aim of preserving the structural elements. We discuss critical conditions of the printing system and present a 3-stage approach to adapt a trabecular structure from $\mu$CT data while incorporating knowledge about the printing system. In the first stage, an image-based extraction of solid and void structures is performed, which results in voxel- and graph-based representations of the extracted structures. These representations not only allow us to quantify geometrical properties such as pore size or strut geometry and length. But, since the graph represents the geometry and the topology of the initial structure, it can be used in the second stage to modify and adjust feature size, volume and sample size in an easy and consistent way. In the final reconstruction stage, the graph is then converted into a voxel representation preserving the topology of the initial structure. This stage generates a model with respect to the printing conditions to ensure a stable and controlled voxel placement during the printing process. T3 - ZIB-Report - 17-26 KW - trabecular structures KW - image-based analysis KW - additive manufacturing KW - printability Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-64004 SN - 1438-0064 ER - TY - JOUR A1 - Redemann, Stefanie A1 - Baumgart, Johannes A1 - Lindow, Norbert A1 - Shelley, Michael A1 - Nazockdast, Ehssan A1 - Kratz, Andrea A1 - Prohaska, Steffen A1 - Brugués, Jan A1 - Fürthauer, Sebastian A1 - Müller-Reichert, Thomas T1 - C. elegans chromosomes connect to centrosomes by anchoring into the spindle network JF - Nature Communications N2 - The mitotic spindle ensures the faithful segregation of chromosomes. Here we combine the first large-scale serial electron tomography of whole mitotic spindles in early C. elegans embryos with live-cell imaging to reconstruct all microtubules in 3D and identify their plus- and minus-ends. We classify them as kinetochore (KMTs), spindle (SMTs) or astral microtubules (AMTs) according to their positions, and quantify distinct properties of each class. While our light microscopy and mutant studies show that microtubules are nucleated from the centrosomes, we find only a few KMTs directly connected to the centrosomes. Indeed, by quantitatively analysing several models of microtubule growth, we conclude that minus-ends of KMTs have selectively detached and depolymerized from the centrosome. In toto, our results show that the connection between centrosomes and chromosomes is mediated by an anchoring into the entire spindle network and that any direct connections through KMTs are few and likely very transient. Y1 - 2017 U6 - https://doi.org/10.1038/ncomms15288 VL - 8 IS - 15288 ER - TY - JOUR A1 - Paetsch, Olaf A1 - Baum, Daniel A1 - Prohaska, Steffen A1 - Ehrig, Karsten A1 - Ebell, Gino A1 - Meinel, Dietmar A1 - Heyn, Andreas T1 - Korrosionsverfolgung in 3D-computertomographischen Aufnahmen von Stahlbetonproben JF - DGZfP-Jahrestagung 2014 Konferenzband Y1 - 2014 ER - TY - GEN A1 - Paetsch, Olaf A1 - Baum, Daniel A1 - Ebell, Gino A1 - Ehrig, Karsten A1 - Heyn, Andreas A1 - Meinel, Dietmar A1 - Prohaska, Steffen T1 - Korrosionsverfolgung in 3D-computertomographischen Aufnahmen von Stahlbetonproben N2 - Kurzfassung. Durch die Alkalität des Betons wird Betonstahl dauerhaft vor Korrosion geschützt. Infolge von Chlorideintrag kann dieser Schutz nicht länger aufrechterhalten werden und führt zu Lochkorrosion. Die zerstörungsfreie Prüfung von Stahlbetonproben mit 3D-CT bietet die Möglichkeit, eine Probe mehrfach gezielt vorzuschädigen und den Korrosionsfortschritt zu untersuchen. Zur Quantifizierung des Schädigungsgrades müssen die bei dieser Untersuchung anfallenden großen Bilddaten mit Bildverarbeitungsmethoden ausgewertet werden. Ein wesentlicher Schritt dabei ist die Segmentierung der Bilddaten, bei der zwischen Korrosionsprodukt (Rost), Betonstahl (BSt), Beton, Rissen, Poren und Umgebung unterschieden werden muss. Diese Segmentierung bildet die Grundlage für statistische Untersuchungen des Schädigungsfortschritts. Hierbei sind die Änderung der BSt-Geometrie, die Zunahme von Korrosionsprodukten und deren Veränderung über die Zeit sowie ihrer räumlichen Verteilung in der Probe von Interesse. Aufgrund der Größe der CT-Bilddaten ist eine manuelle Segmentierung nicht durchführbar, so dass automatische Verfahren unabdingbar sind. Dabei ist insbesondere die Segmentierung der Korrosionsprodukte in den Bilddaten ein schwieriges Problem. Allein aufgrund der Grauwerte ist eine Zuordnung nahezu unmöglich, denn die Grauwerte von Beton und Korrosionsprodukt unterscheiden sich kaum. Eine formbasierte Suche ist nicht offensichtlich, da die Korrosionsprodukte in Beton diffuse Formen haben. Allerdings lässt sich Vorwissen über die Ausbreitung der Korrosionsprodukte nutzen. Sie bilden sich in räumlicher Nähe des BSt (in Bereichen vorheriger Volumenabnahme des BSt), entlang von Rissen sowie in Porenräumen, die direkt am BSt und in dessen Nahbereich liegen. Davon ausgehend wird vor der Korrosionsprodukterkennung zunächst eine BSt-Volumen-, Riss- und Porenerkennung durchgeführt. Dieser in der Arbeit näher beschriebene Schritt erlaubt es, halbautomatisch Startpunkte (Seed Points) für die Korrosionsprodukterkennung zu finden. Weiterhin werden verschiedene in der Bildverarbeitung bekannte Algorithmen auf ihre Eignung untersucht werden. T3 - ZIB-Report - 14-24 KW - Beton KW - Korrosionserkennung KW - Bildverarbeitung KW - Computertomografie KW - concrete KW - corrosiondetection KW - image processing KW - computed tomography Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-50912 SN - 1438-0064 ER - TY - GEN A1 - Osterland, Marc A1 - Benn, Andreas A1 - Prohaska, Steffen A1 - Schütte, Christof T1 - Single Cell Tracking in Phase-Contrast Microscopy T2 - EMBL Symposium 2015 - Seeing is Believing - Imaging the Processes of Life N2 - In this work, we developed an automatic algorithm to analyze cell migration in chemotaxis assays, based on phase-contrast time-lapse microscopy. While manual approaches are still widely used in recent publications, our algorithm is able to track hundreds of single cells per frame. The extracted paths are analysed with traditional geometrical approaches as well as diffusion-driven Markov state models (MSM). Based on these models, a detailed view on spatial and temporal effects is possible. Using our new approach on experimental data, we are able to distinguish between directed migration (e.g. towards a VEGF gradient) and random migration without favored direction. A calculation of the committor probabilities reveals that cells of the whole image area are more likely to migrate directly towards the VEGF than away from it during the first four hours. However, in absence of a chemoattractant, cells migrate more likely to their nearest image border. These conclusions are supported by the spatial mean directions. In a next step, the cell-cell interaction during migration and the migration of cell clusters will be analyzed. Furthermore, we want to observe phenotypical changes during migration based on fluorescence microscopy and machine learning. The algorithm is part of a collaborative platform which brings the experimental expertise of scientists from life sciences and the analytical knowledge of computer scientists together. This platform is built using web-based technologies with a responsive real-time user interface. All data, including raw and metadata as well as the accompanying results, will be stored in a secure and scalable compute cluster. The compute cluster provides sufficient space and computational power for modern image-based experiments and their analyses. Specific versions of data and results can be tagged to keep immutable records for archival. Y1 - 2015 ER -