TY - JOUR A1 - Sekuboyina, Anjany A1 - Bayat, Amirhossein A1 - Husseini, Malek E. A1 - Löffler, Maximilian A1 - Li, Hongwei A1 - Tetteh, Giles A1 - Kukačka, Jan A1 - Payer, Christian A1 - Štern, Darko A1 - Urschler, Martin A1 - Chen, Maodong A1 - Cheng, Dalong A1 - Lessmann, Nikolas A1 - Hu, Yujin A1 - Wang, Tianfu A1 - Yang, Dong A1 - Xu, Daguang A1 - Ambellan, Felix A1 - Amiranashvili, Tamaz A1 - Ehlke, Moritz A1 - Lamecker, Hans A1 - Lehnert, Sebastian A1 - Lirio, Marilia A1 - de Olaguer, Nicolás Pérez A1 - Ramm, Heiko A1 - Sahu, Manish A1 - Tack, Alexander A1 - Zachow, Stefan A1 - Jiang, Tao A1 - Ma, Xinjun A1 - Angerman, Christoph A1 - Wang, Xin A1 - Wei, Qingyue A1 - Brown, Kevin A1 - Wolf, Matthias A1 - Kirszenberg, Alexandre A1 - Puybareau, Élodie A1 - Valentinitsch, Alexander A1 - Rempfler, Markus A1 - Menze, Björn H. A1 - Kirschke, Jan S. T1 - VerSe: A Vertebrae Labelling and Segmentation Benchmark for Multi-detector CT Images JF - arXiv Y1 - 2020 ER - TY - THES A1 - Ehlke, Moritz T1 - 3D Reconstruction of Anatomical Structures from 2D X-ray Images Y1 - 2020 UR - https://depositonce.tu-berlin.de/handle/11303/12753 U6 - https://doi.org/https://doi.org/10.14279/depositonce-11553 ER - TY - JOUR A1 - Ehlke, Moritz A1 - Ramm, Heiko A1 - Lamecker, Hans A1 - Hege, Hans-Christian A1 - Zachow, Stefan T1 - Fast Generation of Virtual X-ray Images for Reconstruction of 3D Anatomy JF - IEEE Transactions on Visualization and Computer Graphics Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-35928 VL - 19 IS - 12 SP - 2673 EP - 2682 ER - TY - GEN A1 - Ehlke, Moritz A1 - Ramm, Heiko A1 - Lamecker, Hans A1 - Zachow, Stefan T1 - Efficient projection and deformation of volumetric shape and intensity models for accurate simulation of X-ray images T2 - Eurographics Workshop on Visual Computing for Biomedicine (NVIDIA best poster award) Y1 - 2012 ER - TY - CHAP A1 - Ehlke, Moritz A1 - Heyland, Mark A1 - Märdian, Sven A1 - Duda, Georg A1 - Zachow, Stefan T1 - 3D Assessment of Osteosynthesis based on 2D Radiographs T2 - Proceedings of the Jahrestagung der Deutschen Gesellschaft für Computer- und Roboterassistierte Chirurgie (CURAC) N2 - We present a novel method to derive the surface distance of an osteosynthesis plate w.r.t. the patient-specific surface of the distal femur based on postoperative 2D radiographs. In a first step, the implant geometry is used as a calibration object to relate the implant and the individual X-ray images spatially in a virtual X-ray setup. Second, the patient- specific femoral shape and pose are reconstructed by fitting a deformable statistical shape and intensity model (SSIM) to the X-rays. The relative positioning between femur and implant is then assessed in terms of the displacement between the reconstructed 3D shape of the femur and the plate. We believe that the approach presented in this paper constitutes a meaningful tool to elucidate the effect of implant positioning on fracture healing and, ultimately, to derive load recommendations after surgery. KW - 3d-reconstruction from 2d X-rays KW - osteosynthesis follow-up KW - statistical shape and intensity models Y1 - 2015 SP - 317 EP - 321 ER - TY - GEN A1 - Ehlke, Moritz A1 - Heyland, Mark A1 - Märdian, Sven A1 - Duda, Georg A1 - Zachow, Stefan T1 - 3D Assessment of Osteosynthesis based on 2D Radiographs N2 - We present a novel method to derive the surface distance of an osteosynthesis plate w.r.t. the patient-specific surface of the distal femur based on postoperative 2D radiographs. In a first step, the implant geometry is used as a calibration object to relate the implant and the individual X-ray images spatially in a virtual X-ray setup. Second, the patient-specific femoral shape and pose are reconstructed by fitting a deformable statistical shape and intensity model (SSIM) to the X-rays. The relative positioning between femur and implant is then assessed in terms of the displacement between the reconstructed 3D shape of the femur and the plate. We believe that the approach presented in this paper constitutes a meaningful tool to elucidate the effect of implant positioning on fracture healing and, ultimately, to derive load recommendations after surgery. T3 - ZIB-Report - 15-47 KW - 3d-reconstruction from 2d X-rays KW - statistical shape and intensity models KW - osteosynthesis follow-up Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-56217 SN - 1438-0064 ER - TY - CHAP A1 - Ehlke, Moritz A1 - Heyland, Mark A1 - Märdian, Sven A1 - Duda, Georg A1 - Zachow, Stefan T1 - Assessing the relative positioning of an osteosynthesis plate to the patient-specific femoral shape from plain 2D radiographs T2 - Proceedings of the 15th Annual Meeting of CAOS-International (CAOS) N2 - We present a novel method to derive the surface distance of an osteosynthesis plate w.r.t. the patient­specific surface of the distal femur based on 2D X­ray images. Our goal is to study from clinical data, how the plate­to­bone distance affects bone healing. The patient­specific 3D shape of the femur is, however, seldom recorded for cases of femoral osteosynthesis since this typically requires Computed Tomography (CT), which comes at high cost and radiation dose. Our method instead utilizes two postoperative X­ray images to derive the femoral shape and thus can be applied on radiographs that are taken in clinical routine for follow­up. First, the implant geometry is used as a calibration object to relate the implant and the individual X­ray images spatially in a virtual X­ray setup. In a second step, the patient­specific femoral shape and pose are reconstructed in the virtual setup by fitting a deformable statistical shape and intensity model (SSIM) to the images. The relative positioning between femur and implant is then assessed in terms of displacement between the reconstructed 3D shape of the femur and the plate. A preliminary evaluation based on 4 cadaver datasets shows that the method derives the plate­to­bone distance with a mean absolute error of less than 1mm and a maximum error of 4.7 mm compared to ground truth from CT. We believe that the approach presented in this paper constitutes a meaningful tool to elucidate the effect of implant positioning on fracture healing. KW - 3d-­reconstruction from 2d X­rays KW - statistical shape and intensity models KW - fracture fixation of the distal femur KW - pose estimation Y1 - 2015 ER - TY - GEN A1 - Ehlke, Moritz A1 - Heyland, Mark A1 - Märdian, Sven A1 - Duda, Georg A1 - Zachow, Stefan T1 - Assessing the Relative Positioning of an Osteosynthesis Plate to the Patient-Specific Femoral Shape from Plain 2D Radiographs N2 - We present a novel method to derive the surface distance of an osteosynthesis plate w.r.t. the patient­specific surface of the distal femur based on 2D X­ray images. Our goal is to study from clinical data, how the plate­to­bone distance affects bone healing. The patient­specific 3D shape of the femur is, however, seldom recorded for cases of femoral osteosynthesis since this typically requires Computed Tomography (CT), which comes at high cost and radiation dose. Our method instead utilizes two postoperative X­ray images to derive the femoral shape and thus can be applied on radiographs that are taken in clinical routine for follow­up. First, the implant geometry is used as a calibration object to relate the implant and the individual X­ray images spatially in a virtual X­ray setup. In a second step, the patient­specific femoral shape and pose are reconstructed in the virtual setup by fitting a deformable statistical shape and intensity model (SSIM) to the images. The relative positioning between femur and implant is then assessed in terms of displacement between the reconstructed 3D shape of the femur and the plate. A preliminary evaluation based on 4 cadaver datasets shows that the method derives the plate­to­bone distance with a mean absolute error of less than 1mm and a maximum error of 4.7 mm compared to ground truth from CT. We believe that the approach presented in this paper constitutes a meaningful tool to elucidate the effect of implant positioning on fracture healing. T3 - ZIB-Report - 15-21 KW - 3d-­reconstruction from 2d X­rays KW - statistical shape and intensity models KW - fracture fixation of the distal femur KW - pose estimation Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-54268 SN - 1438-0064 ER - TY - CHAP A1 - Ehlke, Moritz A1 - Frenzel, Thomas A1 - Ramm, Heiko A1 - Shandiz, Mohsen Akbari A1 - Anglin, Carolyn A1 - Zachow, Stefan T1 - Towards Robust Measurement Of Pelvic Parameters From AP Radiographs Using Articulated 3D Models T2 - Computer Assisted Radiology and Surgery (CARS) N2 - Patient-specific parameters such as the orientation of the acetabulum or pelvic tilt are useful for custom planning for total hip arthroplasty (THA) and for evaluating the outcome of surgical interventions. The gold standard in obtaining pelvic parameters is from three-dimensional (3D) computed tomography (CT) imaging. However, this adds time and cost, exposes the patient to a substantial radiation dose, and does not allow for imaging under load (e.g. while the patient is standing). If pelvic parameters could be reliably derived from the standard anteroposterior (AP) radiograph, preoperative planning would be more widespread, and research analyses could be applied to retrospective data, after a postoperative issue is discovered. The goal of this work is to enable robust measurement of two surgical parameters of interest: the tilt of the anterior pelvic plane (APP) and the orientation of the natural acetabulum. We present a computer-aided reconstruction method to determine the APP and natural acetabular orientation from a single, preoperative X-ray. It can easily be extended to obtain other important preoperative and postoperative parameters solely based on a single AP radiograph. KW - Articulated Models, Statistical Shape And Intensity Models, 2D/3D Anatomy Reconstruction, Pelvic Parameters Measurement, Total Hip Arthroplasty Y1 - 2015 ER - TY - GEN A1 - Ehlke, Moritz A1 - Frenzel, Thomas A1 - Ramm, Heiko A1 - Shandiz, Mohsen Akbari A1 - Anglin, Carolyn A1 - Zachow, Stefan T1 - Towards Robust Measurement of Pelvic Parameters from AP Radiographs using Articulated 3D Models N2 - Patient-specific parameters such as the orientation of the acetabulum or pelvic tilt are useful for custom planning for total hip arthroplasty (THA) and for evaluating the outcome of surgical interventions. The gold standard in obtaining pelvic parameters is from three-dimensional (3D) computed tomography (CT) imaging. However, this adds time and cost, exposes the patient to a substantial radiation dose, and does not allow for imaging under load (e.g. while the patient is standing). If pelvic parameters could be reliably derived from the standard anteroposterior (AP) radiograph, preoperative planning would be more widespread, and research analyses could be applied to retrospective data, after a postoperative issue is discovered. The goal of this work is to enable robust measurement of two surgical parameters of interest: the tilt of the anterior pelvic plane (APP) and the orientation of the natural acetabulum. We present a computer-aided reconstruction method to determine the APP and natural acetabular orientation from a single, preoperative X-ray. It can easily be extended to obtain other important preoperative and postoperative parameters solely based on a single AP radiograph. T3 - ZIB-Report - 15-11 KW - Articulated Models, Statistical Shape And Intensity Models, 2D/3D Anatomy Reconstruction, Pelvic Parameters Measurement, Total Hip Arthroplasty Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-53707 SN - 1438-0064 ER - TY - GEN A1 - Ehlke, Moritz A1 - Frenzel, Thomas A1 - Ramm, Heiko A1 - Lamecker, Hans A1 - Akbari Shandiz, Mohsen A1 - Anglin, Carolyn A1 - Zachow, Stefan T1 - Robust Measurement of Natural Acetabular Orientation from AP Radiographs using Articulated 3D Shape and Intensity Models T3 - ZIB-Report - 14-12 KW - articulated shape and intensity models KW - 3D reconstruction KW - acetabular orientation KW - image registration Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-49824 SN - 1438-0064 ER - TY - GEN A1 - Lamas-Rodríguez, Julián A1 - Ehlke, Moritz A1 - Hoffmann, René A1 - Zachow, Stefan T1 - GPU-accelerated denoising of large tomographic data sets with low SNR BT - Application for non-invasive analysis of paleontological data N2 - Enhancements in tomographic imaging techniques facilitate non-destructive methods for visualizing fossil structures. However, to penetrate dense materials such as sediments or pyrites, image acquisition is typically performed with high beam energy and very sensitive image intensifiers, leading to artifacts and noise in the acquired data. The analysis of delicate fossil structures requires the images to be captured in maximum resolution, resulting in large data sets of several giga bytes (GB) in size. Since the structural information of interest is often almost in the same spatial range as artifacts and noise, image processing and segmentation algorithms have to cope with a very low signal-to-noise ratio (SNR). Within this report we present a study on the performance of a collection of denoising algorithms applied to a very noisy fossil dataset. The study shows that a non-local means (NLM) filter, in case it is properly configured, is able to remove a considerable amount of noise while preserving most of the structural information of interest. Based on the results of this study, we developed a software tool within ZIBAmira that denoises large tomographic datasets using an adaptive, GPU-accelerated NLM filter. With the help of our implementation a user can interactively configure the filter's parameters and thus its effectiveness with respect to the data of interest, while the filtering response is instantly visualized for a preselected region of interest (ROI). Our implementation efficiently denoises even large fossil datasets in a reasonable amount of time. T3 - ZIB-Report - 15-14 Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-56339 SN - 1438-0064 ER - TY - JOUR A1 - Li, Jianning A1 - Pimentel, Pedro A1 - Szengel, Angelika A1 - Ehlke, Moritz A1 - Lamecker, Hans A1 - Zachow, Stefan A1 - Estacio, Laura A1 - Doenitz, Christian A1 - Ramm, Heiko A1 - Shi, Haochen A1 - Chen, Xiaojun A1 - Matzkin, Franco A1 - Newcombe, Virginia A1 - Ferrante, Enzo A1 - Jin, Yuan A1 - Ellis, David G. A1 - Aizenberg, Michele R. A1 - Kodym, Oldrich A1 - Spanel, Michal A1 - Herout, Adam A1 - Mainprize, James G. A1 - Fishman, Zachary A1 - Hardisty, Michael R. A1 - Bayat, Amirhossein A1 - Shit, Suprosanna A1 - Wang, Bomin A1 - Liu, Zhi A1 - Eder, Matthias A1 - Pepe, Antonio A1 - Gsaxner, Christina A1 - Alves, Victor A1 - Zefferer, Ulrike A1 - von Campe, Cord A1 - Pistracher, Karin A1 - Schäfer, Ute A1 - Schmalstieg, Dieter A1 - Menze, Bjoern H. A1 - Glocker, Ben A1 - Egger, Jan T1 - AutoImplant 2020 - First MICCAI Challenge on Automatic Cranial Implant Design JF - IEEE Transactions on Medical Imaging N2 - The aim of this paper is to provide a comprehensive overview of the MICCAI 2020 AutoImplant Challenge. The approaches and publications submitted and accepted within the challenge will be summarized and reported, highlighting common algorithmic trends and algorithmic diversity. Furthermore, the evaluation results will be presented, compared and discussed in regard to the challenge aim: seeking for low cost, fast and fully automated solutions for cranial implant design. Based on feedback from collaborating neurosurgeons, this paper concludes by stating open issues and post-challenge requirements for intra-operative use. Y1 - 2021 U6 - https://doi.org/10.1109/TMI.2021.3077047 SN - 0278-0062 VL - 40 IS - 9 SP - 2329 EP - 2342 ER - TY - JOUR A1 - Sekuboyina, Anjany A1 - Husseini, Malek E. A1 - Bayat, Amirhossein A1 - Löffler, Maximilian A1 - Liebl, Hans A1 - Li, Hongwei A1 - Tetteh, Giles A1 - Kukačka, Jan A1 - Payer, Christian A1 - Štern, Darko A1 - Urschler, Martin A1 - Chen, Maodong A1 - Cheng, Dalong A1 - Lessmann, Nikolas A1 - Hu, Yujin A1 - Wang, Tianfu A1 - Yang, Dong A1 - Xu, Daguang A1 - Ambellan, Felix A1 - Amiranashvili, Tamaz A1 - Ehlke, Moritz A1 - Lamecker, Hans A1 - Lehnert, Sebastian A1 - Lirio, Marilia A1 - de Olaguer, Nicolás Pérez A1 - Ramm, Heiko A1 - Sahu, Manish A1 - Tack, Alexander A1 - Zachow, Stefan A1 - Jiang, Tao A1 - Ma, Xinjun A1 - Angerman, Christoph A1 - Wang, Xin A1 - Brown, Kevin A1 - Kirszenberg, Alexandre A1 - Puybareau, Élodie A1 - Chen, Di A1 - Bai, Yiwei A1 - Rapazzo, Brandon H. A1 - Yeah, Timyoas A1 - Zhang, Amber A1 - Xu, Shangliang A1 - Hou, Feng A1 - He, Zhiqiang A1 - Zeng, Chan A1 - Xiangshang, Zheng A1 - Liming, Xu A1 - Netherton, Tucker J. A1 - Mumme, Raymond P. A1 - Court, Laurence E. A1 - Huang, Zixun A1 - He, Chenhang A1 - Wang, Li-Wen A1 - Ling, Sai Ho A1 - Huynh, Lê Duy A1 - Boutry, Nicolas A1 - Jakubicek, Roman A1 - Chmelik, Jiri A1 - Mulay, Supriti A1 - Sivaprakasam, Mohanasankar A1 - Paetzold, Johannes C. A1 - Shit, Suprosanna A1 - Ezhov, Ivan A1 - Wiestler, Benedikt A1 - Glocker, Ben A1 - Valentinitsch, Alexander A1 - Rempfler, Markus A1 - Menze, Björn H. A1 - Kirschke, Jan S. T1 - VerSe: A Vertebrae labelling and segmentation benchmark for multi-detector CT images JF - Medical Image Analysis N2 - Vertebral labelling and segmentation are two fundamental tasks in an automated spine processing pipeline. Reliable and accurate processing of spine images is expected to benefit clinical decision support systems for diagnosis, surgery planning, and population-based analysis of spine and bone health. However, designing automated algorithms for spine processing is challenging predominantly due to considerable variations in anatomy and acquisition protocols and due to a severe shortage of publicly available data. Addressing these limitations, the Large Scale Vertebrae Segmentation Challenge (VerSe) was organised in conjunction with the International Conference on Medical Image Computing and Computer Assisted Intervention (MICCAI) in 2019 and 2020, with a call for algorithms tackling the labelling and segmentation of vertebrae. Two datasets containing a total of 374 multi-detector CT scans from 355 patients were prepared and 4505 vertebrae have individually been annotated at voxel level by a human-machine hybrid algorithm (https://osf.io/nqjyw/, https://osf.io/t98fz/). A total of 25 algorithms were benchmarked on these datasets. In this work, we present the results of this evaluation and further investigate the performance variation at the vertebra level, scan level, and different fields of view. We also evaluate the generalisability of the approaches to an implicit domain shift in data by evaluating the top-performing algorithms of one challenge iteration on data from the other iteration. The principal takeaway from VerSe: the performance of an algorithm in labelling and segmenting a spine scan hinges on its ability to correctly identify vertebrae in cases of rare anatomical variations. The VerSe content and code can be accessed at: https://github.com/anjany/verse. Y1 - 2021 U6 - https://doi.org/10.1016/j.media.2021.102166 VL - 73 ER -