TY - GEN A1 - Titschack, Jürgen A1 - Baum, Daniel T1 - Advanced computed tomography analyses of cold-water coral mound cores: new insights into mound formation processes T2 - Poster, 19th International Sedimentological Congress, Geneva, Switzerland, 2014, August 18 - 22 Y1 - 2014 ER - TY - CHAP A1 - Hege, Hans-Christian T1 - Visual analysis of molecular dynamics data using geometric and topological methods T2 - Forum "Math for Industry" 2014 Y1 - 2014 VL - 57 SP - 45 EP - 46 PB - Institute of Mathematics for Industry, Kyushu University CY - Fukuoka, Japan ER - TY - THES A1 - von Hafe Pérez Ferreira da Silva, Maria Isabel T1 - Computational Left-Ventricle Reconstruction from MRI Data for Patient-specific Cardiac Simulations Y1 - 2014 ER - TY - CHAP A1 - Bonneau, Georges-Pierre A1 - Hege, Hans-Christian A1 - Johnson, Chris R. A1 - Oliveira, Manuel M. A1 - Potter, Kristin A1 - Rheingans, Penny A1 - Schultz, Thomas T1 - Overview and State-of-the-Art of Uncertainty Visualization T2 - Scientific Visualization - Uncertainty, Multifield, Biomedical, and Scalable Visualization N2 - The goal of visualization is to effectively and accurately communicate data. Visualization research has often overlooked the errors and uncertainty which accompany the scientific process and describe key characteristics used to fully understand the data. The lack of these representations can be attributed, in part, to the inherent difficulty in defining, characterizing, and controlling this uncertainty, and in part, to the difficulty in including additional visual metaphors in a well designed, potent display. However, the exclusion of this information cripples the use of visualization as a decision making tool due to the fact that the display is no longer a true representation of the data. This systematic omission of uncertainty commands fundamental research within the visualization community to address, integrate, and expect uncertainty information. In this chapter, we outline sources and models of uncertainty, give an overview of the state-of-the-art, provide general guidelines, outline small exemplary applications, and finally, discuss open problems in uncertainty visualization. Y1 - 2014 SN - 978-1-4471-6496-8 U6 - https://doi.org/10.1007/978-1-4471-6497-5_1 SP - 3 EP - 27 PB - Springer ER - TY - CHAP A1 - Pfister, Hanspeter A1 - Kaynig, Verena A1 - Botha, Charl P. A1 - Bruckner, Stefan A1 - Dercksen, Vincent J. A1 - Hege, Hans-Christian A1 - Roerdink, Jos B.T.M. ED - Hansen, Charles D. ED - Chen, Min ED - Johnson, Christopher R. ED - Kaufman, Arie E. ED - Hagen, Hans T1 - Visualization in Connectomics T2 - Scientific Visualization - Uncertainty, Multifield, Biomedical, and Scalable Visualization N2 - Connectomics is a branch of neuroscience that attempts to create a connectome, i.e., a complete map of the neuronal system and all connections between neuronal structures. This representation can be used to understand how functional brain states emerge from their underlying anatomical structures and how dysfunction and neuronal diseases arise. We review the current state-of-the-art of visualization and image processing techniques in the field of connectomics and describe a number of challenges. After a brief summary of the biological background and an overview of relevant imaging modalities, we review current techniques to extract connectivity information from image data at macro-, meso- and microscales. We also discuss data integration and neural network modeling, as well as the visualization, analysis and comparison of brain networks. Y1 - 2014 SN - 978-1-4471-6496-8 U6 - https://doi.org/10.1007/978-1-4471-6497-5_21 SP - 221 EP - 245 PB - Springer ER - TY - CHAP A1 - Stoppel, Sergej A1 - Hege, Hans-Christian A1 - Wiebel, Alexander T1 - Visibility-driven depth determination of surface patches in direct volume rendering T2 - EuroVis - Short Papers 2014 N2 - This paper presents an algorithm called surfseek for selecting surfaces on the most visible features in direct volume rendering (DVR). The algorithm is based on a previously published technique (WYSIWYP) for picking 3D locations in DVR. The new algorithm projects a surface patch on the DVR image, consisting of multiple rays. For each ray the algorithm uses WYSIWYP or a variant of it to find the candidates for the most visible locations along the ray. Using these candidates the algorithm constructs a graph and computes a minimum cut on this graph. The minimum cut represents a visible and typically rather smooth surface. In the last step the selected surface is displayed. We provide examples for results using artificially generated and real-world data sets. Y1 - 2014 U6 - https://doi.org/10.2312/eurovisshort.20141164 SP - 97 EP - 101 ER - TY - JOUR A1 - Goubergrits, Leonid A1 - Spuler, Andreas A1 - Schaller, Jens A1 - Wiegmann, Nils A1 - Berthe, Andre A1 - Hege, Hans-Christian A1 - Affeld, Klaus A1 - Kertzscher, Ulrich T1 - In vitro study of hemodynamic treatment improvement: Hunterian ligation of a fenestrated basilar artery aneurysm after coiling JF - The International Journal of Artificial Organs N2 - Hunterian ligation affecting hemodynamics in vessels was proposed to avoid rebleeding in a case of a fenestrated basilar artery aneurysm after incomplete coil occlusion. We studied the hemodynamics in vitro to predict the hemodynamic changes near the aneurysm remnant caused by Hunterian ligation. A transparent model was fabricated based on three-dimensional rotational angiography imaging. Arteries were segmented and reconstructed. Pulsatile flow in the artery segments near the partially occluded (coiled) aneurysm was investigated by means of particle image velocimetry. The hemodynamic situation was investigated before and after Hunterian ligation of either the left or the right vertebral artery (LVA/RVA). Since post-ligation flow rate in the basilar artery was unknown, reduced and retained flow rates were simulated for both ligation options. Flow in the RVA and in the corresponding fenestra vessel is characterized by a vortex at the vertebrobasilar junction, whereas the LVA exhibits undisturbed laminar flow. Both options (RVA or LVA ligation) cause a significant flow reduction near the aneurysm remnant with a retained flow rate. The impact of RVA ligation is, however, significantly higher. This in vitro case study shows that flow reduction near the aneurysm remnant can be achieved by Hunterian ligation and that this effect depends largely on the selection of the ligated vessel. Thus the ability of the proposed in vitro pipe-line to improve hemodynamic impact of the proposed therapy was successfully proved. Y1 - 2014 U6 - https://doi.org/10.5301/ijao.5000314 VL - 37 IS - 4 SP - 325 EP - 335 ER - TY - JOUR A1 - Egger, Robert A1 - Dercksen, Vincent J. A1 - Udvary, Daniel A1 - Hege, Hans-Christian A1 - Oberlaender, Marcel T1 - Generation of dense statistical connectomes from sparse morphological data JF - Frontiers in Neuroanatomy Y1 - 2014 U6 - https://doi.org/10.3389/fnana.2014.00129 VL - 8 IS - 129 ER - TY - JOUR A1 - Lindow, Norbert A1 - Baum, Daniel A1 - Hege, Hans-Christian T1 - Ligand Excluded Surface: A New Type of Molecular Surface JF - IEEE Transactions on Visualization and Computer Graphics N2 - The most popular molecular surface in molecular visualization is the solvent excluded surface (SES). It provides information about the accessibility of a biomolecule for a solvent molecule that is geometrically approximated by a sphere. During a period of almost four decades, the SES has served for many purposes – including visualization, analysis of molecular interactions and the study of cavities in molecular structures. However, if one is interested in the surface that is accessible to a molecule whose shape differs significantly from a sphere, a different concept is necessary. To address this problem, we generalize the definition of the SES by replacing the probe sphere with the full geometry of the ligand defined by the arrangement of its van der Waals spheres. We call the new surface ligand excluded surface (LES) and present an efficient, grid-based algorithm for its computation. Furthermore, we show that this algorithm can also be used to compute molecular cavities that could host the ligand molecule. We provide a detailed description of its implementation on CPU and GPU. Furthermore, we present a performance and convergence analysis and compare the LES for several molecules, using as ligands either water or small organic molecules. Y1 - 2014 U6 - https://doi.org/10.1109/TVCG.2014.2346404 VL - 20 IS - 12 SP - 2486 EP - 2495 ER - TY - GEN A1 - Lindow, Norbert A1 - Baum, Daniel A1 - Hege, Hans-Christian T1 - Ligand Excluded Surface: A New Type of Molecular Surface N2 - The most popular molecular surface in molecular visualization is the solvent excluded surface (SES). It provides information about the accessibility of a biomolecule for a solvent molecule that is geometrically approximated by a sphere. During a period of almost four decades, the SES has served for many purposes – including visualization, analysis of molecular interactions and the study of cavities in molecular structures. However, if one is interested in the surface that is accessible to a molecule whose shape differs significantly from a sphere, a different concept is necessary. To address this problem, we generalize the definition of the SES by replacing the probe sphere with the full geometry of the ligand defined by the arrangement of its van der Waals spheres. We call the new surface ligand excluded surface (LES) and present an efficient, grid-based algorithm for its computation. Furthermore, we show that this algorithm can also be used to compute molecular cavities that could host the ligand molecule. We provide a detailed description of its implementation on CPU and GPU. Furthermore, we present a performance and convergence analysis and compare the LES for several molecules, using as ligands either water or small organic molecules. T3 - ZIB-Report - 14-27 Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0297-zib-51194 SN - 1438-0064 ER -