@misc{EhlkeRammLameckeretal.2013, author = {Ehlke, Moritz and Ramm, Heiko and Lamecker, Hans and Hege, Hans-Christian and Zachow, Stefan}, title = {Fast Generation of Virtual X-ray Images from Deformable Tetrahedral Meshes}, issn = {1438-0064}, url = {http://nbn-resolving.de/urn:nbn:de:0297-zib-41896}, year = {2013}, abstract = {We propose a novel GPU-based approach to render virtual X-ray projections of deformable tetrahedral meshes. These meshes represent the shape and the internal density distribution of a particular anatomical structure and are derived from statistical shape and intensity models (SSIMs). We apply our method to improve the geometric reconstruction of 3D anatomy (e.g.\ pelvic bone) from 2D X-ray images. For that purpose, shape and density of a tetrahedral mesh are varied and virtual X-ray projections are generated within an optimization process until the similarity between the computed virtual X-ray and the respective anatomy depicted in a given clinical X-ray is maximized. The OpenGL implementation presented in this work deforms and projects tetrahedral meshes of high resolution (200.000+ tetrahedra) at interactive rates. It generates virtual X-rays that accurately depict the density distribution of an anatomy of interest. Compared to existing methods that accumulate X-ray attenuation in deformable meshes, our novel approach significantly boosts the deformation/projection performance. The proposed projection algorithm scales better with respect to mesh resolution and complexity of the density distribution, and the combined deformation and projection on the GPU scales better with respect to the number of deformation parameters. The gain in performance allows for a larger number of cycles in the optimization process. Consequently, it reduces the risk of being stuck in a local optimum. We believe that our approach contributes in orthopedic surgery, where 3D anatomy information needs to be extracted from 2D X-rays to support surgeons in better planning joint replacements.}, language = {en} } @misc{Ehlke2012, type = {Master Thesis}, author = {Ehlke, Moritz}, title = {Simulating X-ray images from deformable shape and intensity models on the GPU}, year = {2012}, language = {en} } @misc{EhlkeRammLameckeretal.2012, author = {Ehlke, Moritz and Ramm, Heiko and Lamecker, Hans and Zachow, Stefan}, title = {Efficient projection and deformation of volumetric intensity models for accurate simulation of X-ray images}, issn = {1438-0064}, url = {http://nbn-resolving.de/urn:nbn:de:0297-zib-16580}, year = {2012}, abstract = {We present an efficient GPU-based method to generate virtual X-ray images from tetrahedral meshes which are associated with attenuation values. In addition, a novel approach is proposed that performs the model deformation on the GPU. The tetrahedral grids are derived from volumetric statistical shape and intensity models (SSIMs) and describe anatomical structures. Our research targets at reconstructing 3D anatomical shapes by comparing virtual X-ray images generated using our novel approach with clinical data while varying the shape and density of the SSIM in an optimization process. We assume that a deformed SSIM adequately represents an anatomy of interest when the similarity between the virtual and the clinical X-ray image is maximized. The OpenGL implementation presented here generates accurate (virtual) X-ray images at interactive rates, thus qualifying it for its use in the reconstruction process.}, language = {en} } @misc{Bindernagel2013, type = {Master Thesis}, author = {Bindernagel, Matthias}, title = {Articulated Statistical Shape Models}, year = {2013}, language = {en} } @inproceedings{EstacioEhlkeTacketal.2021, author = {Estacio, Laura and Ehlke, Moritz and Tack, Alexander and Castro-Gutierrez, Eveling and Lamecker, Hans and Mora, Rensso and Zachow, Stefan}, title = {Unsupervised Detection of Disturbances in 2D Radiographs}, booktitle = {2021 IEEE 18th International Symposium on Biomedical Imaging (ISBI)}, doi = {10.1109/ISBI48211.2021.9434091}, pages = {367 -- 370}, year = {2021}, abstract = {We present a method based on a generative model for detection of disturbances such as prosthesis, screws, zippers, and metals in 2D radiographs. The generative model is trained in an unsupervised fashion using clinical radiographs as well as simulated data, none of which contain disturbances. Our approach employs a latent space consistency loss which has the benefit of identifying similarities, and is enforced to reconstruct X-rays without disturbances. In order to detect images with disturbances, an anomaly score is computed also employing the Frechet distance between the input X-ray and the reconstructed one using our generative model. Validation was performed using clinical pelvis radiographs. We achieved an AUC of 0.77 and 0.83 with clinical and synthetic data, respectively. The results demonstrated a good accuracy of our method for detecting outliers as well as the advantage of utilizing synthetic data.}, language = {en} } @article{EhlkeRammLameckeretal.2013, author = {Ehlke, Moritz and Ramm, Heiko and Lamecker, Hans and Hege, Hans-Christian and Zachow, Stefan}, title = {Fast Generation of Virtual X-ray Images for Reconstruction of 3D Anatomy}, volume = {19}, journal = {IEEE Transactions on Visualization and Computer Graphics}, number = {12}, doi = {10.1109/TVCG.2013.159}, url = {http://nbn-resolving.de/urn:nbn:de:0297-zib-35928}, pages = {2673 -- 2682}, year = {2013}, language = {en} } @article{DworzakLameckervonBergetal.2009, author = {Dworzak, Jalda and Lamecker, Hans and von Berg, Jens and Klinder, Tobias and Lorenz, Cristian and Kainm{\"u}ller, Dagmar and Seim, Heiko and Hege, Hans-Christian and Zachow, Stefan}, title = {3D Reconstruction of the Human Rib Cage from 2D Projection Images using a Statistical Shape Model}, volume = {5}, journal = {Int. J. Comput. Assist. Radiol. Surg.}, number = {2}, publisher = {Springer}, issn = {1861-6410}, doi = {10.1007/s11548-009-0390-2}, pages = {111 -- 124}, year = {2009}, language = {en} } @misc{EhlkeRammLameckeretal.2012, author = {Ehlke, Moritz and Ramm, Heiko and Lamecker, Hans and Zachow, Stefan}, title = {Efficient projection and deformation of volumetric shape and intensity models for accurate simulation of X-ray images}, journal = {Eurographics Workshop on Visual Computing for Biomedicine (NVIDIA best poster award)}, year = {2012}, language = {en} } @inproceedings{DworzakLameckervonBergetal.2008, author = {Dworzak, Jalda and Lamecker, Hans and von Berg, Jens and Klinder, Tobias and Lorenz, Cristian and Kainm{\"u}ller, Dagmar and Seim, Heiko and Hege, Hans-Christian and Zachow, Stefan}, title = {Towards model-based 3-D reconstruction of the human rib cage from radiographs}, booktitle = {Proc. 7. Jahrestagung der Deutschen Gesellschaft f{\"u}r Computer-Roboterassistierte Chirurgie (CURAC)}, pages = {193 -- 196}, year = {2008}, language = {en} } @inproceedings{LameckerWenckebachHege2006, author = {Lamecker, Hans and Wenckebach, Thomas and Hege, Hans-Christian}, title = {Atlas-based 3D-shape reconstruction from x-ray images}, volume = {Volume I}, booktitle = {Proc. Int. Conf. of Pattern Recognition (ICPR2006)}, publisher = {IEEE Computer Society}, doi = {10.1109/ICPR.2006.279}, pages = {371 -- 374}, year = {2006}, language = {en} } @inproceedings{LameckerWenckebachHegeetal.2006, author = {Lamecker, Hans and Wenckebach, Thomas and Hege, Hans-Christian and N. Duda, Georg and Heller, Markus}, title = {Atlas-basierte 3D-Rekonstruktion des Beckens aus 2D-Projektionsbildern}, booktitle = {Bildverarbeitung f{\"u}r die Medizin 2006: Algorithmen - Systeme - Anwendungen}, publisher = {Springer Berlin Heidelberg}, doi = {10.1007/3-540-32137-3_6}, pages = {26 -- 30}, year = {2006}, language = {en} } @inproceedings{EhlkeHeylandMaerdianetal.2015, author = {Ehlke, Moritz and Heyland, Mark and M{\"a}rdian, Sven and Duda, Georg and Zachow, Stefan}, title = {3D Assessment of Osteosynthesis based on 2D Radiographs}, booktitle = {Proceedings of the Jahrestagung der Deutschen Gesellschaft f{\"u}r Computer- und Roboterassistierte Chirurgie (CURAC)}, pages = {317 -- 321}, year = {2015}, abstract = {We present a novel method to derive the surface distance of an osteosynthesis plate w.r.t. the patient-specific surface of the distal femur based on postoperative 2D radiographs. In a first step, the implant geometry is used as a calibration object to relate the implant and the individual X-ray images spatially in a virtual X-ray setup. Second, the patient- specific femoral shape and pose are reconstructed by fitting a deformable statistical shape and intensity model (SSIM) to the X-rays. The relative positioning between femur and implant is then assessed in terms of the displacement between the reconstructed 3D shape of the femur and the plate. We believe that the approach presented in this paper constitutes a meaningful tool to elucidate the effect of implant positioning on fracture healing and, ultimately, to derive load recommendations after surgery.}, language = {en} } @misc{EhlkeHeylandMaerdianetal.2015, author = {Ehlke, Moritz and Heyland, Mark and M{\"a}rdian, Sven and Duda, Georg and Zachow, Stefan}, title = {3D Assessment of Osteosynthesis based on 2D Radiographs}, issn = {1438-0064}, url = {http://nbn-resolving.de/urn:nbn:de:0297-zib-56217}, year = {2015}, abstract = {We present a novel method to derive the surface distance of an osteosynthesis plate w.r.t. the patient-specific surface of the distal femur based on postoperative 2D radiographs. In a first step, the implant geometry is used as a calibration object to relate the implant and the individual X-ray images spatially in a virtual X-ray setup. Second, the patient-specific femoral shape and pose are reconstructed by fitting a deformable statistical shape and intensity model (SSIM) to the X-rays. The relative positioning between femur and implant is then assessed in terms of the displacement between the reconstructed 3D shape of the femur and the plate. We believe that the approach presented in this paper constitutes a meaningful tool to elucidate the effect of implant positioning on fracture healing and, ultimately, to derive load recommendations after surgery.}, language = {en} } @misc{EhlkeHeylandMaerdianetal.2015, author = {Ehlke, Moritz and Heyland, Mark and M{\"a}rdian, Sven and Duda, Georg and Zachow, Stefan}, title = {Assessing the Relative Positioning of an Osteosynthesis Plate to the Patient-Specific Femoral Shape from Plain 2D Radiographs}, issn = {1438-0064}, url = {http://nbn-resolving.de/urn:nbn:de:0297-zib-54268}, year = {2015}, abstract = {We present a novel method to derive the surface distance of an osteosynthesis plate w.r.t. the patient­specific surface of the distal femur based on 2D X­ray images. Our goal is to study from clinical data, how the plate­to­bone distance affects bone healing. The patient­specific 3D shape of the femur is, however, seldom recorded for cases of femoral osteosynthesis since this typically requires Computed Tomography (CT), which comes at high cost and radiation dose. Our method instead utilizes two postoperative X­ray images to derive the femoral shape and thus can be applied on radiographs that are taken in clinical routine for follow­up. First, the implant geometry is used as a calibration object to relate the implant and the individual X­ray images spatially in a virtual X­ray setup. In a second step, the patient­specific femoral shape and pose are reconstructed in the virtual setup by fitting a deformable statistical shape and intensity model (SSIM) to the images. The relative positioning between femur and implant is then assessed in terms of displacement between the reconstructed 3D shape of the femur and the plate. A preliminary evaluation based on 4 cadaver datasets shows that the method derives the plate­to­bone distance with a mean absolute error of less than 1mm and a maximum error of 4.7 mm compared to ground truth from CT. We believe that the approach presented in this paper constitutes a meaningful tool to elucidate the effect of implant positioning on fracture healing.}, language = {en} } @inproceedings{EhlkeFrenzelRammetal.2015, author = {Ehlke, Moritz and Frenzel, Thomas and Ramm, Heiko and Shandiz, Mohsen Akbari and Anglin, Carolyn and Zachow, Stefan}, title = {Towards Robust Measurement Of Pelvic Parameters From AP Radiographs Using Articulated 3D Models}, booktitle = {Computer Assisted Radiology and Surgery (CARS)}, year = {2015}, abstract = {Patient-specific parameters such as the orientation of the acetabulum or pelvic tilt are useful for custom planning for total hip arthroplasty (THA) and for evaluating the outcome of surgical interventions. The gold standard in obtaining pelvic parameters is from three-dimensional (3D) computed tomography (CT) imaging. However, this adds time and cost, exposes the patient to a substantial radiation dose, and does not allow for imaging under load (e.g. while the patient is standing). If pelvic parameters could be reliably derived from the standard anteroposterior (AP) radiograph, preoperative planning would be more widespread, and research analyses could be applied to retrospective data, after a postoperative issue is discovered. The goal of this work is to enable robust measurement of two surgical parameters of interest: the tilt of the anterior pelvic plane (APP) and the orientation of the natural acetabulum. We present a computer-aided reconstruction method to determine the APP and natural acetabular orientation from a single, preoperative X-ray. It can easily be extended to obtain other important preoperative and postoperative parameters solely based on a single AP radiograph.}, language = {en} } @misc{EhlkeFrenzelRammetal.2015, author = {Ehlke, Moritz and Frenzel, Thomas and Ramm, Heiko and Shandiz, Mohsen Akbari and Anglin, Carolyn and Zachow, Stefan}, title = {Towards Robust Measurement of Pelvic Parameters from AP Radiographs using Articulated 3D Models}, issn = {1438-0064}, url = {http://nbn-resolving.de/urn:nbn:de:0297-zib-53707}, year = {2015}, abstract = {Patient-specific parameters such as the orientation of the acetabulum or pelvic tilt are useful for custom planning for total hip arthroplasty (THA) and for evaluating the outcome of surgical interventions. The gold standard in obtaining pelvic parameters is from three-dimensional (3D) computed tomography (CT) imaging. However, this adds time and cost, exposes the patient to a substantial radiation dose, and does not allow for imaging under load (e.g. while the patient is standing). If pelvic parameters could be reliably derived from the standard anteroposterior (AP) radiograph, preoperative planning would be more widespread, and research analyses could be applied to retrospective data, after a postoperative issue is discovered. The goal of this work is to enable robust measurement of two surgical parameters of interest: the tilt of the anterior pelvic plane (APP) and the orientation of the natural acetabulum. We present a computer-aided reconstruction method to determine the APP and natural acetabular orientation from a single, preoperative X-ray. It can easily be extended to obtain other important preoperative and postoperative parameters solely based on a single AP radiograph.}, language = {en} } @misc{EhlkeFrenzelRammetal.2014, author = {Ehlke, Moritz and Frenzel, Thomas and Ramm, Heiko and Lamecker, Hans and Akbari Shandiz, Mohsen and Anglin, Carolyn and Zachow, Stefan}, title = {Robust Measurement of Natural Acetabular Orientation from AP Radiographs using Articulated 3D Shape and Intensity Models}, issn = {1438-0064}, url = {http://nbn-resolving.de/urn:nbn:de:0297-zib-49824}, year = {2014}, language = {en} } @article{ZahnGrotjohannRammetal.2016, author = {Zahn, Robert and Grotjohann, Sarah and Ramm, Heiko and Zachow, Stefan and Pumberger, Matthias and Putzier, Michael and Perka, Carsten and Tohtz, Stephan}, title = {Influence of pelvic tilt on functional acetabular orientation}, volume = {25}, journal = {Technology and Health Care}, number = {3}, publisher = {IOS Press}, doi = {10.3233/THC-161281}, pages = {557 -- 565}, year = {2016}, language = {en} }