@article{ZahnGrotjohannRammetal., author = {Zahn, Robert and Grotjohann, Sarah and Ramm, Heiko and Zachow, Stefan and Pumberger, Matthias and Putzier, Michael and Perka, Carsten and Tohtz, Stephan}, title = {Influence of pelvic tilt on functional acetabular orientation}, series = {Technology and Health Care}, volume = {25}, journal = {Technology and Health Care}, number = {3}, publisher = {IOS Press}, doi = {10.3233/THC-161281}, pages = {557 -- 565}, language = {en} } @article{ZahnGrotjohannRammetal., author = {Zahn, Robert and Grotjohann, Sarah and Ramm, Heiko and Zachow, Stefan and Putzier, Michael and Perka, Carsten and Tohtz, Stephan}, title = {Pelvic tilt compensates for increased acetabular anteversion}, series = {International Orthopaedics}, volume = {40}, journal = {International Orthopaedics}, number = {8}, doi = {10.1007/s00264-015-2949-6}, pages = {1571 -- 1575}, abstract = {Pelvic tilt determines functional orientation of the acetabulum. In this study, we investigated the interaction of pelvic tilt and functional acetabular anteversion (AA) in supine position.}, language = {en} } @inproceedings{RammVictoriaMorilloTodtetal.2013, author = {Ramm, Heiko and Victoria Morillo, Oscar Salvador and Todt, Ingo and Schirmacher, Hartmut and Ernst, Arneborg and Zachow, Stefan and Lamecker, Hans}, title = {Visual Support for Positioning Hearing Implants}, series = {Proceedings of the 12th annual meeting of the CURAC society}, booktitle = {Proceedings of the 12th annual meeting of the CURAC society}, editor = {Freysinger, Wolfgang}, pages = {116 -- 120}, year = {2013}, language = {en} } @misc{SKGBSetal.2011, author = {SK, Saevarsson and GB, Sharma and S, Montgomery and KCT, Ho and Ramm, Heiko and Lieck, Robert and Zachow, Stefan and C, Anglin}, title = {Kinematic Comparison Between Gender Specific and Traditional Femoral Implants}, series = {Proceedings of the 11th Alberta Biomedical Engineering (BME) Conference (Poster)}, journal = {Proceedings of the 11th Alberta Biomedical Engineering (BME) Conference (Poster)}, pages = {80}, year = {2011}, language = {en} } @misc{EhlkeRammLameckeretal.2012, author = {Ehlke, Moritz and Ramm, Heiko and Lamecker, Hans and Zachow, Stefan}, title = {Efficient projection and deformation of volumetric shape and intensity models for accurate simulation of X-ray images}, series = {Eurographics Workshop on Visual Computing for Biomedicine (NVIDIA best poster award)}, journal = {Eurographics Workshop on Visual Computing for Biomedicine (NVIDIA best poster award)}, year = {2012}, language = {en} } @article{RammKahntZachow2012, author = {Ramm, Heiko and Kahnt, Max and Zachow, Stefan}, title = {Patientenspezifische Simulationsmodelle f{\"u}r die funktionelle Analyse von k{\"u}nstlichem Gelenkersatz}, series = {Computer Aided Medical Engineering (CaMe)}, volume = {3}, journal = {Computer Aided Medical Engineering (CaMe)}, number = {2}, pages = {30 -- 36}, year = {2012}, language = {de} } @inproceedings{KahntRammLameckeretal.2012, author = {Kahnt, Max and Ramm, Heiko and Lamecker, Hans and Zachow, Stefan}, title = {Feature-Preserving, Multi-Material Mesh Generation using Hierarchical Oracles}, series = {Proc. MICCAI Workshop on Mesh Processing in Medical Image Analysis (MeshMed)}, volume = {7599}, booktitle = {Proc. MICCAI Workshop on Mesh Processing in Medical Image Analysis (MeshMed)}, editor = {Levine, Joshua A. and Paulsen, Rasmus R. and Zhang, Yongjie}, pages = {101 -- 111}, year = {2012}, language = {en} } @incollection{RammZachow2012, author = {Ramm, Heiko and Zachow, Stefan}, title = {Computergest{\"u}tzte Planung f{\"u}r die individuelle Implantatversorgung}, series = {Health Academy}, volume = {16}, booktitle = {Health Academy}, editor = {Niederlag, Wolfgang and Lemke, Heinz and Peitgen, Heinz-Otto and Lehrach, Hans}, pages = {145 -- 158}, year = {2012}, language = {de} } @inproceedings{EhlkeFrenzelRammetal., author = {Ehlke, Moritz and Frenzel, Thomas and Ramm, Heiko and Shandiz, Mohsen Akbari and Anglin, Carolyn and Zachow, Stefan}, title = {Towards Robust Measurement Of Pelvic Parameters From AP Radiographs Using Articulated 3D Models}, series = {Computer Assisted Radiology and Surgery (CARS)}, booktitle = {Computer Assisted Radiology and Surgery (CARS)}, abstract = {Patient-specific parameters such as the orientation of the acetabulum or pelvic tilt are useful for custom planning for total hip arthroplasty (THA) and for evaluating the outcome of surgical interventions. The gold standard in obtaining pelvic parameters is from three-dimensional (3D) computed tomography (CT) imaging. However, this adds time and cost, exposes the patient to a substantial radiation dose, and does not allow for imaging under load (e.g. while the patient is standing). If pelvic parameters could be reliably derived from the standard anteroposterior (AP) radiograph, preoperative planning would be more widespread, and research analyses could be applied to retrospective data, after a postoperative issue is discovered. The goal of this work is to enable robust measurement of two surgical parameters of interest: the tilt of the anterior pelvic plane (APP) and the orientation of the natural acetabulum. We present a computer-aided reconstruction method to determine the APP and natural acetabular orientation from a single, preoperative X-ray. It can easily be extended to obtain other important preoperative and postoperative parameters solely based on a single AP radiograph.}, language = {en} } @misc{EhlkeFrenzelRammetal., author = {Ehlke, Moritz and Frenzel, Thomas and Ramm, Heiko and Shandiz, Mohsen Akbari and Anglin, Carolyn and Zachow, Stefan}, title = {Towards Robust Measurement of Pelvic Parameters from AP Radiographs using Articulated 3D Models}, issn = {1438-0064}, url = {http://nbn-resolving.de/urn:nbn:de:0297-zib-53707}, abstract = {Patient-specific parameters such as the orientation of the acetabulum or pelvic tilt are useful for custom planning for total hip arthroplasty (THA) and for evaluating the outcome of surgical interventions. The gold standard in obtaining pelvic parameters is from three-dimensional (3D) computed tomography (CT) imaging. However, this adds time and cost, exposes the patient to a substantial radiation dose, and does not allow for imaging under load (e.g. while the patient is standing). If pelvic parameters could be reliably derived from the standard anteroposterior (AP) radiograph, preoperative planning would be more widespread, and research analyses could be applied to retrospective data, after a postoperative issue is discovered. The goal of this work is to enable robust measurement of two surgical parameters of interest: the tilt of the anterior pelvic plane (APP) and the orientation of the natural acetabulum. We present a computer-aided reconstruction method to determine the APP and natural acetabular orientation from a single, preoperative X-ray. It can easily be extended to obtain other important preoperative and postoperative parameters solely based on a single AP radiograph.}, language = {en} }