@inproceedings{ZachowHierlErdmann2004, author = {Zachow, Stefan and Hierl, Thomas and Erdmann, Bodo}, title = {On the Predictability of tissue changes after osteotomy planning in maxillofacial surgery}, booktitle = {Computer Assisted Radiology and Surgery (CARS)}, address = {Chicago, USA}, doi = {10.1016/j.ics.2004.03.043}, pages = {648 -- 653}, year = {2004}, language = {en} } @inproceedings{ZachowHierlErdmann2004, author = {Zachow, Stefan and Hierl, Thomas and Erdmann, Bodo}, title = {{\"U}ber die Genauigkeit einer 3D Weichgewebepr{\"a}diktion in der MKG-Cirurgie}, booktitle = {Workshop 'Bildverarbeitung f{\"u}r die Medizin' (BVM)}, address = {Berlin, Germany}, pages = {75 -- 79}, year = {2004}, language = {en} } @inproceedings{LameckerZoecklerHaberletal.2005, author = {Lamecker, Hans and Z{\"o}ckler, Maja and Haberl, Hannes and Zachow, Stefan and Hege, Hans-Christian}, title = {Statistical shape modeling for craniosynostosis planning}, booktitle = {2nd International Conference Advanced Digital Technology in Head and Neck Reconstruction 2005, Abstract Volume}, address = {Banff, Alberta}, pages = {64}, year = {2005}, language = {en} } @article{WestermarkZachowEppley2005, author = {Westermark, Anders and Zachow, Stefan and Eppley, Barry}, title = {3D osteotomy planning in maxillofacial surgery, including 3D soft tissue prediction}, volume = {16(1)}, journal = {Journal of Craniofacial Surgery}, pages = {100 -- 104}, year = {2005}, language = {en} } @article{ZachowHegeDeuflhard2005, author = {Zachow, Stefan and Hege, Hans-Christian and Deuflhard, Peter}, title = {Maxillofacial surgery planning with 3D soft tissue prediction - modeling, planning, simulation}, journal = {2. Int. Conf. on Advanced Digital Technology in Head and Neck Reconstruction, Abstract 33}, address = {Banff, Alberta, CA}, pages = {64}, year = {2005}, language = {en} } @article{LameckerZachowHaberletal.2005, author = {Lamecker, Hans and Zachow, Stefan and Haberl, Hannes and Stiller, Michael}, title = {Medical applications for statistical shape models}, volume = {17 (258)}, journal = {Computer Aided Surgery around the Head, Fortschritt-Berichte VDI - Biotechnik/Medizintechnik}, pages = {61}, year = {2005}, language = {en} } @inproceedings{ZachowLameckerElsholtzetal.2005, author = {Zachow, Stefan and Lamecker, Hans and Elsholtz, Barbara and Stiller, Michael}, title = {Reconstruction of mandibular dysplasia using a statistical 3D shape model}, booktitle = {Proc. Computer Assisted Radiology and Surgery (CARS)}, address = {Berlin, Germany}, doi = {10.1016/j.ics.2005.03.339}, pages = {1238 -- 1243}, year = {2005}, language = {en} } @inproceedings{NkenkeHaeuslerNeukametal.2005, author = {Nkenke, Emeka and H{\"a}usler, Gerd and Neukam, Friedrich and Zachow, Stefan}, title = {Streak artifact correction of CT data by optical 3D imaging in the simulation of orthognathic surgery}, booktitle = {Computer Assisted Radiology and Surgery (CARS)}, address = {Berlin Germany}, doi = {doi:10.1016/j.ics.2005.03.278}, year = {2005}, language = {en} } @inproceedings{NkenkeZachowHaeusler2005, author = {Nkenke, Emeka and Zachow, Stefan and H{\"a}usler, Gerd}, title = {Fusion von optischen 3D- und CT-Daten des Gebisses zur Metallartefaktkorrektur vor computerassistierter Planung MKG-chirurgischer Eingriffe}, booktitle = {Symposium der Arbeitsgemeinschaf f{\"u}r Kieferchirurgie}, address = {Bad Homburg v.d.H}, year = {2005}, language = {en} } @misc{WilsonBuecherGreweetal.2015, author = {Wilson, David and B{\"u}cher, Pia and Grewe, Carl Martin and Anglin, Carolyn and Zachow, Stefan and Michael, Dunbar}, title = {Validation of Three Dimensional Models of the Distal Femur Created from Surgical Navigation Point Cloud Data}, journal = {15th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery (CAOS)}, year = {2015}, language = {en} } @inproceedings{EhlkeHeylandMaerdianetal.2015, author = {Ehlke, Moritz and Heyland, Mark and M{\"a}rdian, Sven and Duda, Georg and Zachow, Stefan}, title = {3D Assessment of Osteosynthesis based on 2D Radiographs}, booktitle = {Proceedings of the Jahrestagung der Deutschen Gesellschaft f{\"u}r Computer- und Roboterassistierte Chirurgie (CURAC)}, pages = {317 -- 321}, year = {2015}, abstract = {We present a novel method to derive the surface distance of an osteosynthesis plate w.r.t. the patient-specific surface of the distal femur based on postoperative 2D radiographs. In a first step, the implant geometry is used as a calibration object to relate the implant and the individual X-ray images spatially in a virtual X-ray setup. Second, the patient- specific femoral shape and pose are reconstructed by fitting a deformable statistical shape and intensity model (SSIM) to the X-rays. The relative positioning between femur and implant is then assessed in terms of the displacement between the reconstructed 3D shape of the femur and the plate. We believe that the approach presented in this paper constitutes a meaningful tool to elucidate the effect of implant positioning on fracture healing and, ultimately, to derive load recommendations after surgery.}, language = {en} } @misc{EhlkeHeylandMaerdianetal.2015, author = {Ehlke, Moritz and Heyland, Mark and M{\"a}rdian, Sven and Duda, Georg and Zachow, Stefan}, title = {3D Assessment of Osteosynthesis based on 2D Radiographs}, issn = {1438-0064}, url = {http://nbn-resolving.de/urn:nbn:de:0297-zib-56217}, year = {2015}, abstract = {We present a novel method to derive the surface distance of an osteosynthesis plate w.r.t. the patient-specific surface of the distal femur based on postoperative 2D radiographs. In a first step, the implant geometry is used as a calibration object to relate the implant and the individual X-ray images spatially in a virtual X-ray setup. Second, the patient-specific femoral shape and pose are reconstructed by fitting a deformable statistical shape and intensity model (SSIM) to the X-rays. The relative positioning between femur and implant is then assessed in terms of the displacement between the reconstructed 3D shape of the femur and the plate. We believe that the approach presented in this paper constitutes a meaningful tool to elucidate the effect of implant positioning on fracture healing and, ultimately, to derive load recommendations after surgery.}, language = {en} } @inproceedings{KraemerHerrmannBoethetal.2015, author = {Kr{\"a}mer, Martin and Herrmann, Karl-Heinz and Boeth, Heide and Tycowicz, Christoph von and K{\"o}nig, Christian and Zachow, Stefan and Ehrig, Rainald and Hege, Hans-Christian and Duda, Georg and Reichenbach, J{\"u}rgen}, title = {Measuring 3D knee dynamics using center out radial ultra-short echo time trajectories with a low cost experimental setup}, booktitle = {ISMRM (International Society for Magnetic Resonance in Medicine), 23rd Annual Meeting 2015, Toronto, Canada}, year = {2015}, language = {en} } @inproceedings{EhlkeHeylandMaerdianetal.2015, author = {Ehlke, Moritz and Heyland, Mark and M{\"a}rdian, Sven and Duda, Georg and Zachow, Stefan}, title = {Assessing the relative positioning of an osteosynthesis plate to the patient-specific femoral shape from plain 2D radiographs}, booktitle = {Proceedings of the 15th Annual Meeting of CAOS-International (CAOS)}, year = {2015}, abstract = {We present a novel method to derive the surface distance of an osteosynthesis plate w.r.t. the patient­specific surface of the distal femur based on 2D X­ray images. Our goal is to study from clinical data, how the plate­to­bone distance affects bone healing. The patient­specific 3D shape of the femur is, however, seldom recorded for cases of femoral osteosynthesis since this typically requires Computed Tomography (CT), which comes at high cost and radiation dose. Our method instead utilizes two postoperative X­ray images to derive the femoral shape and thus can be applied on radiographs that are taken in clinical routine for follow­up. First, the implant geometry is used as a calibration object to relate the implant and the individual X­ray images spatially in a virtual X­ray setup. In a second step, the patient­specific femoral shape and pose are reconstructed in the virtual setup by fitting a deformable statistical shape and intensity model (SSIM) to the images. The relative positioning between femur and implant is then assessed in terms of displacement between the reconstructed 3D shape of the femur and the plate. A preliminary evaluation based on 4 cadaver datasets shows that the method derives the plate­to­bone distance with a mean absolute error of less than 1mm and a maximum error of 4.7 mm compared to ground truth from CT. We believe that the approach presented in this paper constitutes a meaningful tool to elucidate the effect of implant positioning on fracture healing.}, language = {en} } @misc{EhlkeHeylandMaerdianetal.2015, author = {Ehlke, Moritz and Heyland, Mark and M{\"a}rdian, Sven and Duda, Georg and Zachow, Stefan}, title = {Assessing the Relative Positioning of an Osteosynthesis Plate to the Patient-Specific Femoral Shape from Plain 2D Radiographs}, issn = {1438-0064}, url = {http://nbn-resolving.de/urn:nbn:de:0297-zib-54268}, year = {2015}, abstract = {We present a novel method to derive the surface distance of an osteosynthesis plate w.r.t. the patient­specific surface of the distal femur based on 2D X­ray images. Our goal is to study from clinical data, how the plate­to­bone distance affects bone healing. The patient­specific 3D shape of the femur is, however, seldom recorded for cases of femoral osteosynthesis since this typically requires Computed Tomography (CT), which comes at high cost and radiation dose. Our method instead utilizes two postoperative X­ray images to derive the femoral shape and thus can be applied on radiographs that are taken in clinical routine for follow­up. First, the implant geometry is used as a calibration object to relate the implant and the individual X­ray images spatially in a virtual X­ray setup. In a second step, the patient­specific femoral shape and pose are reconstructed in the virtual setup by fitting a deformable statistical shape and intensity model (SSIM) to the images. The relative positioning between femur and implant is then assessed in terms of displacement between the reconstructed 3D shape of the femur and the plate. A preliminary evaluation based on 4 cadaver datasets shows that the method derives the plate­to­bone distance with a mean absolute error of less than 1mm and a maximum error of 4.7 mm compared to ground truth from CT. We believe that the approach presented in this paper constitutes a meaningful tool to elucidate the effect of implant positioning on fracture healing.}, language = {en} } @article{CampoliBakaKapteinetal.2014, author = {Campoli, Gianni and Baka, Nora and Kaptein, Bart and Valstar, Edward and Zachow, Stefan and Weinans, Harrie and Zadpoor, Amir Abbas}, title = {Relationship between the shape and density distribution of the femur and its natural frequencies of vibration}, volume = {47}, journal = {Journal of Biomechanics}, publisher = {Elsevier}, doi = {10.1016/j.jbiomech.2014.08.008}, pages = {3334 -- 3343}, year = {2014}, abstract = {It has been recently suggested that mechanical loads applied at frequencies close to the natural frequencies of bone could enhance bone apposition due to the resonance phenomenon. Other applications of bone modal analysis are also suggested. For the above-mentioned applications, it is important to understand how patient-specific bone shape and density distribution influence the natural frequencies of bones. We used finite element models to study the effects of bone shape and density distribution on the natural frequencies of the femur in free boundary conditions. A statistical shape and appearance model that describes shape and density distribution independently was created, based on a training set of 27 femora. The natural frequencies were then calculated for different shape modes varied around the mean shape while keeping the mean density distribution, for different appearance modes around the mean density distribution while keeping the mean bone shape, and for the 27 training femora. Single shape or appearance modes could cause up to 15\% variations in the natural frequencies with certain modes having the greatest impact. For the actual femora, shape and density distribution changed the natural frequencies by up to 38\%. First appearance mode that describes the general cortical bone thickness and trabecular bone density had one of the strongest impacts. The first appearance mode could therefore provide a sensitive measure of general bone health and disease progression. Since shape and density could cause large variations in the calculated natural frequencies, patient-specific FE models are needed for accurate estimation of bone natural frequencies.}, language = {en} } @article{HochfeldLameckerThomaleetal.2014, author = {Hochfeld, Mascha and Lamecker, Hans and Thomale, Ulrich W. and Schulz, Matthias and Zachow, Stefan and Haberl, Hannes}, title = {Frame-based cranial reconstruction}, volume = {13}, journal = {Journal of Neurosurgery: Pediatrics}, number = {3}, doi = {10.3171/2013.11.PEDS1369}, pages = {319 -- 323}, year = {2014}, abstract = {The authors report on the first experiences with the prototype of a surgical tool for cranial remodeling. The device enables the surgeon to transfer statistical information, represented in a model, into the disfigured bone. The model is derived from a currently evolving databank of normal head shapes. Ultimately, the databank will provide a set of standard models covering the statistical range of normal head shapes, thus providing the required template for any standard remodeling procedure as well as customized models for intended overcorrection. To date, this technique has been used in the surgical treatment of 14 infants (age range 6-12 months) with craniosynostosis. In all 14 cases, the designated esthetic result, embodied by the selected model, has been achieved, without morbidity or mortality. Frame-based reconstruction provides the required tools to precisely realize the surgical reproduction of the model shape. It enables the establishment of a self-referring system, feeding back postoperative growth patterns, recorded by 3D follow-up, into the model design.}, language = {en} } @article{LemanisZachowFusseisetal.2015, author = {Lemanis, Robert and Zachow, Stefan and Fusseis, Florian and Hoffmann, Ren{\´e}}, title = {A new approach using high-resolution computed tomography to test the buoyant properties of chambered cephalopod shells}, volume = {41}, journal = {Paleobiology}, number = {2}, publisher = {Cambridge University Press}, address = {Cambridge}, doi = {10.1017/pab.2014.17}, pages = {313 -- 329}, year = {2015}, abstract = {The chambered shell of modern cephalopods functions as a buoyancy apparatus, allowing the animal to enter the water column without expending a large amount of energy to overcome its own weight. Indeed, the chambered shell is largely considered a key adaptation that allowed the earliest cephalopods to leave the ocean floor and enter the water column. It has been argued by some, however, that the iconic chambered shell of Paleozoic and Mesozoic ammonoids did not provide a sufficiently buoyant force to compensate for the weight of the entire animal, thus restricting ammonoids to a largely benthic lifestyle reminiscent of some octopods. Here we develop a technique using high-resolution computed tomography to quantify the buoyant properties of chambered shells without reducing the shell to ideal spirals or eliminating inherent biological variability by using mathematical models that characterize past work in this area. This technique has been tested on Nautilus pompilius and is now extended to the extant deep-sea squid Spirula spirula and the Jurassic ammonite Cadoceras sp. hatchling. Cadoceras is found to have possessed near-neutral to positive buoyancy if hatched when the shell possessed between three and five chambers. However, we show that the animal could also overcome degrees of negative buoyancy through swimming, similar to the paralarvae of modern squids. These calculations challenge past inferences of benthic life habits based solely on calculations of negative buoyancy. The calculated buoyancy of Cadoceras supports the possibility of planktonic dispersal of ammonite hatchlings. This information is essential to understanding ammonoid ecology as well as biotic interactions and has implications for the interpretation of geochemical data gained from the isotopic analysis of the shell.}, language = {en} } @inproceedings{EhlkeFrenzelRammetal.2015, author = {Ehlke, Moritz and Frenzel, Thomas and Ramm, Heiko and Shandiz, Mohsen Akbari and Anglin, Carolyn and Zachow, Stefan}, title = {Towards Robust Measurement Of Pelvic Parameters From AP Radiographs Using Articulated 3D Models}, booktitle = {Computer Assisted Radiology and Surgery (CARS)}, year = {2015}, abstract = {Patient-specific parameters such as the orientation of the acetabulum or pelvic tilt are useful for custom planning for total hip arthroplasty (THA) and for evaluating the outcome of surgical interventions. The gold standard in obtaining pelvic parameters is from three-dimensional (3D) computed tomography (CT) imaging. However, this adds time and cost, exposes the patient to a substantial radiation dose, and does not allow for imaging under load (e.g. while the patient is standing). If pelvic parameters could be reliably derived from the standard anteroposterior (AP) radiograph, preoperative planning would be more widespread, and research analyses could be applied to retrospective data, after a postoperative issue is discovered. The goal of this work is to enable robust measurement of two surgical parameters of interest: the tilt of the anterior pelvic plane (APP) and the orientation of the natural acetabulum. We present a computer-aided reconstruction method to determine the APP and natural acetabular orientation from a single, preoperative X-ray. It can easily be extended to obtain other important preoperative and postoperative parameters solely based on a single AP radiograph.}, language = {en} } @misc{EhlkeFrenzelRammetal.2015, author = {Ehlke, Moritz and Frenzel, Thomas and Ramm, Heiko and Shandiz, Mohsen Akbari and Anglin, Carolyn and Zachow, Stefan}, title = {Towards Robust Measurement of Pelvic Parameters from AP Radiographs using Articulated 3D Models}, issn = {1438-0064}, url = {http://nbn-resolving.de/urn:nbn:de:0297-zib-53707}, year = {2015}, abstract = {Patient-specific parameters such as the orientation of the acetabulum or pelvic tilt are useful for custom planning for total hip arthroplasty (THA) and for evaluating the outcome of surgical interventions. The gold standard in obtaining pelvic parameters is from three-dimensional (3D) computed tomography (CT) imaging. However, this adds time and cost, exposes the patient to a substantial radiation dose, and does not allow for imaging under load (e.g. while the patient is standing). If pelvic parameters could be reliably derived from the standard anteroposterior (AP) radiograph, preoperative planning would be more widespread, and research analyses could be applied to retrospective data, after a postoperative issue is discovered. The goal of this work is to enable robust measurement of two surgical parameters of interest: the tilt of the anterior pelvic plane (APP) and the orientation of the natural acetabulum. We present a computer-aided reconstruction method to determine the APP and natural acetabular orientation from a single, preoperative X-ray. It can easily be extended to obtain other important preoperative and postoperative parameters solely based on a single AP radiograph.}, language = {en} }