@article{ZahnGrotjohannRammetal., author = {Zahn, Robert and Grotjohann, Sarah and Ramm, Heiko and Zachow, Stefan and Putzier, Michael and Perka, Carsten and Tohtz, Stephan}, title = {Pelvic tilt compensates for increased acetabular anteversion}, series = {International Orthopaedics}, volume = {40}, journal = {International Orthopaedics}, number = {8}, doi = {10.1007/s00264-015-2949-6}, pages = {1571 -- 1575}, abstract = {Pelvic tilt determines functional orientation of the acetabulum. In this study, we investigated the interaction of pelvic tilt and functional acetabular anteversion (AA) in supine position.}, language = {en} } @article{ZachowHeppt, author = {Zachow, Stefan and Heppt, Werner}, title = {The Facial Profile}, series = {Facial Plastic Surgery}, volume = {31}, journal = {Facial Plastic Surgery}, number = {5}, doi = {10.1055/s-0035-1566132}, pages = {419 -- 420}, abstract = {Facial appearance in our societies is often associated with notions of attractiveness, juvenileness, beauty, success, and so forth. Hence, the role of facial plastic surgery is highly interrelated to a patient's desire to feature many of these positively connoted attributes, which of course, are subject of different cultural perceptions or social trends. To judge about somebody's facial appearance, appropriate quantitative measures as well as methods to obtain and compare individual facial features are required. This special issue on facial profile is intended to provide an overview on how facial characteristics are surgically managed in an interdisciplinary way based on experience, instrumentation, and modern technology to obtain an aesthetic facial appearance with harmonious facial proportions. The facial profile will be discussed within the context of facial aesthetics. Latest concepts for capturing facial morphology in high speed and impressive detail are presented for quantitative analysis of even subtle changes, aging effects, or facial expressions. In addition, the perception of facial profiles is evaluated based on eye tracking technology.}, language = {en} } @article{Zachow, author = {Zachow, Stefan}, title = {Computational Planning in Facial Surgery}, series = {Facial Plastic Surgery}, volume = {31}, journal = {Facial Plastic Surgery}, number = {5}, doi = {10.1055/s-0035-1564717}, pages = {446 -- 462}, abstract = {This article reflects the research of the last two decades in computational planning for cranio-maxillofacial surgery. Model-guided and computer-assisted surgery planning has tremendously developed due to ever increasing computational capabilities. Simulators for education, planning, and training of surgery are often compared with flight simulators, where maneuvers are also trained to reduce a possible risk of failure. Meanwhile, digital patient models can be derived from medical image data with astonishing accuracy and thus can serve for model surgery to derive a surgical template model that represents the envisaged result. Computerized surgical planning approaches, however, are often still explorative, meaning that a surgeon tries to find a therapeutic concept based on his or her expertise using computational tools that are mimicking real procedures. Future perspectives of an improved computerized planning may be that surgical objectives will be generated algorithmically by employing mathematical modeling, simulation, and optimization techniques. Planning systems thus act as intelligent decision support systems. However, surgeons can still use the existing tools to vary the proposed approach, but they mainly focus on how to transfer objectives into reality. Such a development may result in a paradigm shift for future surgery planning.}, language = {en} } @misc{WilsonBuecherGreweetal., author = {Wilson, David and B{\"u}cher, Pia and Grewe, Carl Martin and Mocanu, Valentin and Anglin, Carolyn and Zachow, Stefan and Dunbar, Michael}, title = {Validation of Three Dimensional Models of the Distal Femur Created from Surgical Navigation Data}, series = {Orthopedic Research Society Annual Meeting}, journal = {Orthopedic Research Society Annual Meeting}, address = {Las Vegas, Nevada}, language = {en} } @misc{WilsonBuecherGreweetal., author = {Wilson, David and B{\"u}cher, Pia and Grewe, Carl Martin and Anglin, Carolyn and Zachow, Stefan and Michael, Dunbar}, title = {Validation of Three Dimensional Models of the Distal Femur Created from Surgical Navigation Point Cloud Data}, series = {15th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery (CAOS)}, journal = {15th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery (CAOS)}, language = {en} } @article{LemanisZachowFusseisetal., author = {Lemanis, Robert and Zachow, Stefan and Fusseis, Florian and Hoffmann, Ren{\´e}}, title = {A new approach using high-resolution computed tomography to test the buoyant properties of chambered cephalopod shells}, series = {Paleobiology}, volume = {41}, journal = {Paleobiology}, number = {2}, publisher = {Cambridge University Press}, address = {Cambridge}, doi = {10.1017/pab.2014.17}, pages = {313 -- 329}, abstract = {The chambered shell of modern cephalopods functions as a buoyancy apparatus, allowing the animal to enter the water column without expending a large amount of energy to overcome its own weight. Indeed, the chambered shell is largely considered a key adaptation that allowed the earliest cephalopods to leave the ocean floor and enter the water column. It has been argued by some, however, that the iconic chambered shell of Paleozoic and Mesozoic ammonoids did not provide a sufficiently buoyant force to compensate for the weight of the entire animal, thus restricting ammonoids to a largely benthic lifestyle reminiscent of some octopods. Here we develop a technique using high-resolution computed tomography to quantify the buoyant properties of chambered shells without reducing the shell to ideal spirals or eliminating inherent biological variability by using mathematical models that characterize past work in this area. This technique has been tested on Nautilus pompilius and is now extended to the extant deep-sea squid Spirula spirula and the Jurassic ammonite Cadoceras sp. hatchling. Cadoceras is found to have possessed near-neutral to positive buoyancy if hatched when the shell possessed between three and five chambers. However, we show that the animal could also overcome degrees of negative buoyancy through swimming, similar to the paralarvae of modern squids. These calculations challenge past inferences of benthic life habits based solely on calculations of negative buoyancy. The calculated buoyancy of Cadoceras supports the possibility of planktonic dispersal of ammonite hatchlings. This information is essential to understanding ammonoid ecology as well as biotic interactions and has implications for the interpretation of geochemical data gained from the isotopic analysis of the shell.}, language = {en} } @misc{LamasRodriguezEhlkeHoffmannetal., author = {Lamas-Rodr{\´i}guez, Juli{\´a}n and Ehlke, Moritz and Hoffmann, Ren{\´e} and Zachow, Stefan}, title = {GPU-accelerated denoising of large tomographic data sets with low SNR}, issn = {1438-0064}, url = {http://nbn-resolving.de/urn:nbn:de:0297-zib-56339}, abstract = {Enhancements in tomographic imaging techniques facilitate non-destructive methods for visualizing fossil structures. However, to penetrate dense materials such as sediments or pyrites, image acquisition is typically performed with high beam energy and very sensitive image intensifiers, leading to artifacts and noise in the acquired data. The analysis of delicate fossil structures requires the images to be captured in maximum resolution, resulting in large data sets of several giga bytes (GB) in size. Since the structural information of interest is often almost in the same spatial range as artifacts and noise, image processing and segmentation algorithms have to cope with a very low signal-to-noise ratio (SNR). Within this report we present a study on the performance of a collection of denoising algorithms applied to a very noisy fossil dataset. The study shows that a non-local means (NLM) filter, in case it is properly configured, is able to remove a considerable amount of noise while preserving most of the structural information of interest. Based on the results of this study, we developed a software tool within ZIBAmira that denoises large tomographic datasets using an adaptive, GPU-accelerated NLM filter. With the help of our implementation a user can interactively configure the filter's parameters and thus its effectiveness with respect to the data of interest, while the filtering response is instantly visualized for a preselected region of interest (ROI). Our implementation efficiently denoises even large fossil datasets in a reasonable amount of time.}, language = {en} } @inproceedings{KraemerHerrmannBoethetal., author = {Kr{\"a}mer, Martin and Herrmann, Karl-Heinz and Boeth, Heide and Tycowicz, Christoph von and K{\"o}nig, Christian and Zachow, Stefan and Ehrig, Rainald and Hege, Hans-Christian and Duda, Georg and Reichenbach, J{\"u}rgen}, title = {Measuring 3D knee dynamics using center out radial ultra-short echo time trajectories with a low cost experimental setup}, series = {ISMRM (International Society for Magnetic Resonance in Medicine), 23rd Annual Meeting 2015, Toronto, Canada}, booktitle = {ISMRM (International Society for Magnetic Resonance in Medicine), 23rd Annual Meeting 2015, Toronto, Canada}, language = {en} } @article{GreweSchreiberZachow, author = {Grewe, Carl Martin and Schreiber, Lisa and Zachow, Stefan}, title = {Fast and Accurate Digital Morphometry of Facial Expressions}, series = {Facial Plastic Surgery}, volume = {31}, journal = {Facial Plastic Surgery}, number = {05}, publisher = {Thieme Medical Publishers}, address = {New York}, doi = {10.1055/s-0035-1564720}, pages = {431 -- 438}, language = {en} } @misc{EhlkeHeylandMaerdianetal., author = {Ehlke, Moritz and Heyland, Mark and M{\"a}rdian, Sven and Duda, Georg and Zachow, Stefan}, title = {Assessing the Relative Positioning of an Osteosynthesis Plate to the Patient-Specific Femoral Shape from Plain 2D Radiographs}, issn = {1438-0064}, url = {http://nbn-resolving.de/urn:nbn:de:0297-zib-54268}, abstract = {We present a novel method to derive the surface distance of an osteosynthesis plate w.r.t. the patient­specific surface of the distal femur based on 2D X­ray images. Our goal is to study from clinical data, how the plate­to­bone distance affects bone healing. The patient­specific 3D shape of the femur is, however, seldom recorded for cases of femoral osteosynthesis since this typically requires Computed Tomography (CT), which comes at high cost and radiation dose. Our method instead utilizes two postoperative X­ray images to derive the femoral shape and thus can be applied on radiographs that are taken in clinical routine for follow­up. First, the implant geometry is used as a calibration object to relate the implant and the individual X­ray images spatially in a virtual X­ray setup. In a second step, the patient­specific femoral shape and pose are reconstructed in the virtual setup by fitting a deformable statistical shape and intensity model (SSIM) to the images. The relative positioning between femur and implant is then assessed in terms of displacement between the reconstructed 3D shape of the femur and the plate. A preliminary evaluation based on 4 cadaver datasets shows that the method derives the plate­to­bone distance with a mean absolute error of less than 1mm and a maximum error of 4.7 mm compared to ground truth from CT. We believe that the approach presented in this paper constitutes a meaningful tool to elucidate the effect of implant positioning on fracture healing.}, language = {en} } @misc{EhlkeHeylandMaerdianetal., author = {Ehlke, Moritz and Heyland, Mark and M{\"a}rdian, Sven and Duda, Georg and Zachow, Stefan}, title = {3D Assessment of Osteosynthesis based on 2D Radiographs}, issn = {1438-0064}, url = {http://nbn-resolving.de/urn:nbn:de:0297-zib-56217}, abstract = {We present a novel method to derive the surface distance of an osteosynthesis plate w.r.t. the patient-specific surface of the distal femur based on postoperative 2D radiographs. In a first step, the implant geometry is used as a calibration object to relate the implant and the individual X-ray images spatially in a virtual X-ray setup. Second, the patient-specific femoral shape and pose are reconstructed by fitting a deformable statistical shape and intensity model (SSIM) to the X-rays. The relative positioning between femur and implant is then assessed in terms of the displacement between the reconstructed 3D shape of the femur and the plate. We believe that the approach presented in this paper constitutes a meaningful tool to elucidate the effect of implant positioning on fracture healing and, ultimately, to derive load recommendations after surgery.}, language = {en} } @inproceedings{EhlkeHeylandMaerdianetal., author = {Ehlke, Moritz and Heyland, Mark and M{\"a}rdian, Sven and Duda, Georg and Zachow, Stefan}, title = {Assessing the relative positioning of an osteosynthesis plate to the patient-specific femoral shape from plain 2D radiographs}, series = {Proceedings of the 15th Annual Meeting of CAOS-International (CAOS)}, booktitle = {Proceedings of the 15th Annual Meeting of CAOS-International (CAOS)}, abstract = {We present a novel method to derive the surface distance of an osteosynthesis plate w.r.t. the patient­specific surface of the distal femur based on 2D X­ray images. Our goal is to study from clinical data, how the plate­to­bone distance affects bone healing. The patient­specific 3D shape of the femur is, however, seldom recorded for cases of femoral osteosynthesis since this typically requires Computed Tomography (CT), which comes at high cost and radiation dose. Our method instead utilizes two postoperative X­ray images to derive the femoral shape and thus can be applied on radiographs that are taken in clinical routine for follow­up. First, the implant geometry is used as a calibration object to relate the implant and the individual X­ray images spatially in a virtual X­ray setup. In a second step, the patient­specific femoral shape and pose are reconstructed in the virtual setup by fitting a deformable statistical shape and intensity model (SSIM) to the images. The relative positioning between femur and implant is then assessed in terms of displacement between the reconstructed 3D shape of the femur and the plate. A preliminary evaluation based on 4 cadaver datasets shows that the method derives the plate­to­bone distance with a mean absolute error of less than 1mm and a maximum error of 4.7 mm compared to ground truth from CT. We believe that the approach presented in this paper constitutes a meaningful tool to elucidate the effect of implant positioning on fracture healing.}, language = {en} } @inproceedings{EhlkeHeylandMaerdianetal., author = {Ehlke, Moritz and Heyland, Mark and M{\"a}rdian, Sven and Duda, Georg and Zachow, Stefan}, title = {3D Assessment of Osteosynthesis based on 2D Radiographs}, series = {Proceedings of the Jahrestagung der Deutschen Gesellschaft f{\"u}r Computer- und Roboterassistierte Chirurgie (CURAC)}, booktitle = {Proceedings of the Jahrestagung der Deutschen Gesellschaft f{\"u}r Computer- und Roboterassistierte Chirurgie (CURAC)}, pages = {317 -- 321}, abstract = {We present a novel method to derive the surface distance of an osteosynthesis plate w.r.t. the patient-specific surface of the distal femur based on postoperative 2D radiographs. In a first step, the implant geometry is used as a calibration object to relate the implant and the individual X-ray images spatially in a virtual X-ray setup. Second, the patient- specific femoral shape and pose are reconstructed by fitting a deformable statistical shape and intensity model (SSIM) to the X-rays. The relative positioning between femur and implant is then assessed in terms of the displacement between the reconstructed 3D shape of the femur and the plate. We believe that the approach presented in this paper constitutes a meaningful tool to elucidate the effect of implant positioning on fracture healing and, ultimately, to derive load recommendations after surgery.}, language = {en} } @inproceedings{EhlkeFrenzelRammetal., author = {Ehlke, Moritz and Frenzel, Thomas and Ramm, Heiko and Shandiz, Mohsen Akbari and Anglin, Carolyn and Zachow, Stefan}, title = {Towards Robust Measurement Of Pelvic Parameters From AP Radiographs Using Articulated 3D Models}, series = {Computer Assisted Radiology and Surgery (CARS)}, booktitle = {Computer Assisted Radiology and Surgery (CARS)}, abstract = {Patient-specific parameters such as the orientation of the acetabulum or pelvic tilt are useful for custom planning for total hip arthroplasty (THA) and for evaluating the outcome of surgical interventions. The gold standard in obtaining pelvic parameters is from three-dimensional (3D) computed tomography (CT) imaging. However, this adds time and cost, exposes the patient to a substantial radiation dose, and does not allow for imaging under load (e.g. while the patient is standing). If pelvic parameters could be reliably derived from the standard anteroposterior (AP) radiograph, preoperative planning would be more widespread, and research analyses could be applied to retrospective data, after a postoperative issue is discovered. The goal of this work is to enable robust measurement of two surgical parameters of interest: the tilt of the anterior pelvic plane (APP) and the orientation of the natural acetabulum. We present a computer-aided reconstruction method to determine the APP and natural acetabular orientation from a single, preoperative X-ray. It can easily be extended to obtain other important preoperative and postoperative parameters solely based on a single AP radiograph.}, language = {en} } @misc{EhlkeFrenzelRammetal., author = {Ehlke, Moritz and Frenzel, Thomas and Ramm, Heiko and Shandiz, Mohsen Akbari and Anglin, Carolyn and Zachow, Stefan}, title = {Towards Robust Measurement of Pelvic Parameters from AP Radiographs using Articulated 3D Models}, issn = {1438-0064}, url = {http://nbn-resolving.de/urn:nbn:de:0297-zib-53707}, abstract = {Patient-specific parameters such as the orientation of the acetabulum or pelvic tilt are useful for custom planning for total hip arthroplasty (THA) and for evaluating the outcome of surgical interventions. The gold standard in obtaining pelvic parameters is from three-dimensional (3D) computed tomography (CT) imaging. However, this adds time and cost, exposes the patient to a substantial radiation dose, and does not allow for imaging under load (e.g. while the patient is standing). If pelvic parameters could be reliably derived from the standard anteroposterior (AP) radiograph, preoperative planning would be more widespread, and research analyses could be applied to retrospective data, after a postoperative issue is discovered. The goal of this work is to enable robust measurement of two surgical parameters of interest: the tilt of the anterior pelvic plane (APP) and the orientation of the natural acetabulum. We present a computer-aided reconstruction method to determine the APP and natural acetabular orientation from a single, preoperative X-ray. It can easily be extended to obtain other important preoperative and postoperative parameters solely based on a single AP radiograph.}, language = {en} }