@article{MatsuyamaTitschackBaumetal.2015, author = {Matsuyama, Kei and Titschack, J{\"u}rgen and Baum, Daniel and Freiwald, Andr{\´e}}, title = {Two new species of erect Bryozoa (Gymnolaemata: Cheilostomata) and the application of non-destructive imaging methods for quantitative taxonomy}, series = {Zootaxa}, volume = {4020}, journal = {Zootaxa}, number = {1}, doi = {10.11646/zootaxa.4020.1.3}, pages = {81 -- 100}, year = {2015}, abstract = {Two new species of cheilostome Bryozoa are described from continental-slope habitats off Mauritania, including canyon and coldwater-coral (mound) habitats. Internal structures of both species were visualised and quantified using micro-computed tomographic (micro-CT) methods. Cellaria bafouri n. sp. is characterised by the arrangement of zooids in alternating longitudinal rows, a smooth cryptocyst, and the presence of an ooecial plate with denticles. Smittina imragueni n. sp. exhibits many similarities with Smittina cervicornis (Pallas, 1766), but differs especially in the shape and orientation of the suboral avicularium. Observations on Smittina imragueni and material labelled as Smittina cervicornis suggest that the latter represents a species group, members of which have not yet been discriminated, possibly because of high intracolony variation and marked astogenetic changes in surface morphology. Both new species are known only from the habitats where they were collected, probably reflecting the paucity of bryozoan sampling from this geographic area and depth range. Both species are able to tolerate low oxygen concentration, which is assumed to be compensated by the high nutrient supply off Mauritania. The application of micro-CT for the semiautomatic quantification of zooidal skeletal characters was successfully tested. We were able to automatically distinguish individual zooidal cavities and acquire corresponding morphological datasets. Comparing the obtained results with conventional SEM measurements allowed ascertaining the reliability of this new method. The employment of micro-CT allows the observation and quantification of previously un- seen characters that can be used in describing and differentiating species that were previously indistinguishable. Further- more, this method might help elucidate processes of colony growth and the function of individual zooids during this process.}, language = {en} } @article{TitschackBaumMatsuyamaetal.2018, author = {Titschack, J{\"u}rgen and Baum, Daniel and Matsuyama, Kei and Boos, Karin and F{\"a}rber, Claudia and Kahl, Wolf-Achim and Ehrig, Karsten and Meinel, Dietmar and Soriano, Carmen and Stock, Stuart R.}, title = {Ambient occlusion - a powerful algorithm to segment shell and skeletal intrapores in computed tomography data}, series = {Computers and Geosciences}, volume = {115}, journal = {Computers and Geosciences}, doi = {10.1016/j.cageo.2018.03.007}, pages = {75 -- 87}, year = {2018}, abstract = {During the last decades, X-ray (micro-)computed tomography has gained increasing attention for the description of porous skeletal and shell structures of various organism groups. However, their quantitative analysis is often hampered by the difficulty to discriminate cavities and pores within the object from the surrounding region. Herein, we test the ambient occlusion (AO) algorithm and newly implemented optimisations for the segmentation of cavities (implemented in the software Amira). The segmentation accuracy is evaluated as a function of (i) changes in the ray length input variable, and (ii) the usage of AO (scalar) field and other AO-derived (scalar) fields. The results clearly indicate that the AO field itself outperforms all other AO-derived fields in terms of segmentation accuracy and robustness against variations in the ray length input variable. The newly implemented optimisations improved the AO field-based segmentation only slightly, while the segmentations based on the AO-derived fields improved considerably. Additionally, we evaluated the potential of the AO field and AO-derived fields for the separation and classification of cavities as well as skeletal structures by comparing them with commonly used distance-map-based segmentations. For this, we tested the zooid separation within a bryozoan colony, the stereom classification of an ophiuroid tooth, the separation of bioerosion traces within a marble block and the calice (central cavity)-pore separation within a dendrophyllid coral. The obtained results clearly indicate that the ideal input field depends on the three-dimensional morphology of the object of interest. The segmentations based on the AO-derived fields often provided cavity separations and skeleton classifications that were superior to or impossible to obtain with commonly used distance- map-based segmentations. The combined usage of various AO-derived fields by supervised or unsupervised segmentation algorithms might provide a promising target for future research to further improve the results for this kind of high-end data segmentation and classification. Furthermore, the application of the developed segmentation algorithm is not restricted to X-ray (micro-)computed tomographic data but may potentially be useful for the segmentation of 3D volume data from other sources.}, language = {en} } @misc{TitschackBaumMatsuyamaetal., author = {Titschack, J{\"u}rgen and Baum, Daniel and Matsuyama, Kei and Boos, Karin and F{\"a}rber, Claudia and Kahl, Wolf-Achim and Ehrig, Karsten and Meinel, Dietmar and Soriano, Carmen and Stock, Stuart R.}, title = {Ambient occlusion - a powerful algorithm to segment shell and skeletal intrapores in computed tomography data}, issn = {1438-0064}, url = {http://nbn-resolving.de/urn:nbn:de:0297-zib-67982}, abstract = {During the last decades, X-ray (micro-)computed tomography has gained increasing attention for the description of porous skeletal and shell structures of various organism groups. However, their quantitative analysis is often hampered by the difficulty to discriminate cavities and pores within the object from the surrounding region. Herein, we test the ambient occlusion (AO) algorithm and newly implemented optimisations for the segmentation of cavities (implemented in the software Amira). The segmentation accuracy is evaluated as a function of (i) changes in the ray length input variable, and (ii) the usage of AO (scalar) field and other AO-derived (scalar) fields. The results clearly indicate that the AO field itself outperforms all other AO-derived fields in terms of segmentation accuracy and robustness against variations in the ray length input variable. The newly implemented optimisations improved the AO field-based segmentation only slightly, while the segmentations based on the AO-derived fields improved considerably. Additionally, we evaluated the potential of the AO field and AO-derived fields for the separation and classification of cavities as well as skeletal structures by comparing them with commonly used distance-map-based segmentations. For this, we tested the zooid separation within a bryozoan colony, the stereom classification of an ophiuroid tooth, the separation of bioerosion traces within a marble block and the calice (central cavity)-pore separation within a dendrophyllid coral. The obtained results clearly indicate that the ideal input field depends on the three-dimensional morphology of the object of interest. The segmentations based on the AO-derived fields often provided cavity separations and skeleton classifications that were superior to or impossible to obtain with commonly used distance- map-based segmentations. The combined usage of various AO-derived fields by supervised or unsupervised segmentation algorithms might provide a promising target for future research to further improve the results for this kind of high-end data segmentation and classification. Furthermore, the application of the developed segmentation algorithm is not restricted to X-ray (micro-)computed tomographic data but may potentially be useful for the segmentation of 3D volume data from other sources.}, language = {en} }