Fachbereich Ingenieur- und Naturwissenschaften
Refine
Document Type
Year of publication
- 2016 (31) (remove)
Institute
Has Fulltext
- yes (31)
Is part of the Bibliography
- yes (31)
Keywords
- next-generation sequencing (2)
- 3D measurement (1)
- 3D metrology (1)
- Android (1)
- BLE (1)
- Bibliotheks-App (1)
- Bibliotheksinformatik (1)
- COLONY software (1)
- Campus-App (1)
- Fabry-Perot (1)
In this work, a measurement concept based on triangulation was developed for borescopic 3D-surveying of surface defects. The integration of such measurement system into a borescope environment requires excellent space utilization. The triangulation angle, the projected pattern, the numerical apertures of the optical system, and the viewing angle were calculated using partial coherence imaging and geometric optical raytracing methods. Additionally, optical aberrations and defocus were considered by the integration of Zernike polynomial coefficients. The measurement system is able to measure objects with a size of 50 μm in all dimensions with an accuracy of ± 5 μm. To manage the issue of a low depth of field while using an optical high resolution system, a wavelength dependent aperture was integrated. Thereby, we are able to control depth of field and resolution of the optical system and can use the borescope in measurement mode with high resolution and low depth of field or in inspection mode with low resolution and higher depth of field. First measurements of a demonstrator system are in good agreement with our simulations.
In this study, we present the experimental investigations on interference patterns, such as those already reported in VIMOS-IFU, and up to now no appropriate explanation has been presented. These interference patterns are produced in multimode fibres coated with acrylate or polyimide, which is the preferred coating material for the fibres used in IFUs. Our experiments show that, under specific conditions, cladding modes interact with the coating and produce interference. Our results show that the conditions at which the fibre is held during data acquisition has an impact in the output spectrum. Altering the positioning conditions of the fibre leads to the changes into the interference pattern, therefore, fibres should be carefully manipulated in order to minimise this potential problem and improve the performance of these instruments. Finally we present a simple way of predicting and modelling this interference produced from the visible to the near infrared spectra. This model can be included in the data reduction pipeline in order to remove the interference patterns.
These results should be of interest for the optimisation of the data reduction pipelines of instruments using optical fibres. Considering these results will benefit innovations and developments of high performance fibre systems.
Fabry-Perot (FP) polymer film sensors offer high acoustic sensitivity, small element sizes, broadband frequency response and optical transmission to enable high resolution, backward mode photoacoustic (PA) imaging. Typical approaches to sensor fabrication involve the deposition of stacks of alternating dielectric materials to form interferometer mirrors, which are separated by a polymer spacer. If hygroscopic soft dielectric materials are used, a protective polymer layer is typically required. In this study, methods for the deposition of water-resistant, hard dielectric materials onto polymers were explored to improve the robustness and performance of the sensors. This involved the optimisation of the fabrication process, the optical and acoustic characterisation of the sensors, and a comparison of the frequency response with the output of an acoustic forward model. The mirrors, which were separated by a 20 μm Parylene spacer, consisted of eight double layers of Ta2O5 and SiO2 deposited onto polymer substrates using temperature-optimised electron vapour deposition. The free spectral range of the interferometer was 32 nm, its finesse FR = 91, and its visibility V = 0.72. The noise-equivalent pressure was 0.3 kPa (20 MHz bandwidth). The measured frequency response was found to be more resonant at 25 MHz compared to sensors with soft dielectric mirrors, which was also in good agreement with the output of a forward model of the sensor. The sensors were used in a PA scanner to acquire 3-D images in tissue phantoms.
3D through silicon via profile metrology based on spectroscopic reflectometry for SOI applications
(2016)
Through-silicon via (TSV) technology is a key feature for 3D circuit integration. TSVs are formed by etching a vertical via and filling them with a conductive material for creation of interconnections which go through the silicon or silicon-on-insulator (SOI) wafer. The Bosch etch process on Deep Reactive Ion Etching (DRIE) is commonly used for this purpose. The etch profile defined by the critical dimensions (CDs) at the top and at the bottom, by the depth and by the scallop size on the sidewall needs to be monitored and well controlled.
In this work a nondestructive 3D metrology of deeply-etched structures with an aspect ratio of more than 10 and patterns with lateral dimensions from 2 to 7 μm in SOI wafer is proposed. Spectroscopic reflectometry in the spectral range of 250-800 nm using a production metrology tool was applied. The depth determinations based on different algorithms are compared.
The Pearson correlation coefficient between measured and calculated reflection is suggested as the most appropriate method. A simple method for top CD evaluation is proposed by the measurement of reflection and using the polynomial approximation of reflection versus TSV filling coefficient which is determined as ratio of CD to pitch. The 3D RCWA simulations confirm this dependence.
In this work, we present for the first time a partially slotted silicon ring resonator (PSRR) covered with an electro-optical polymer (Poly[(methyl methacrylate)-co-(Disperse Red 1 acrylate)]). The PSRR takes advantage of both a highly efficient vertical slot waveguide based phase shifter and a low loss strip waveguide in a single ring. The device is realized on 200 mm silicon-on-insulator wafers using 248 nm DUV lithography and covered with the electro-optic polymer in a post process. This silicon-organic hybrid ring resonator has a small footprint, high optical quality factor, and high DC device tunability. A quality factor of up to 105 and a DC device tunability of about 700 pm/V is experimentally demonstrated in the wavelength range of 1540 nm to 1590 nm. Further, we compare our results with state-of-the-art silicon-organic hybrid devices by determining the poling efficiency. It is demonstrated that the active PSRR is a promising candidate for efficient optical switches and tunable filters.
Motivated by findings of new mineral related water sources for organisms under extremely dry conditions on Earth we studied in an interdisciplinary approach the water sorption behaviour of halite, soil component and terrestrial Nostoc commune biofilm under Mars relevant environmental conditions. Physicochemical methods served for the determination of water sorption equilibrium data and survival of heterotrophic bacteria in biofilm samples with different water contents was assured by recultivation. Deliquescence of halite provides liquid water at temperatures <273 K and may serve as water source on Mars during the morning stabilized by the CO2 atmosphere for a few hours. The protecting biofilm of N. commune is rather hygroscopic and tends to store water at lower humidity values. Survival tests showed that a large proportion of the Alphaproteobacteria dominated microbiota associated to N. commune is very desiccation tolerant and water uptake from saturated NaCl solutions (either by direct uptake of brine or adsorption of humidity) did not enhance recultivability in long-time desiccated samples. Still, a minor part can grow under highly saline conditions. However, the salinity level, although unfavourable for the host organism, might be for parts of the heterotrophic microbiota no serious hindrance for growing in salty Mars-like environments.
Nanocrystalline silicon suboxides (nc-SiOx) have attracted attention during the past years for the use in thin-film silicon solar cells. We investigated the relationships between the nanostructure as well as the chemical, electrical, and optical properties of phosphorous, doped, nc-SiO0.8:H fabricated by plasma-enhanced chemical vapor deposition. The nanostructure was varied through the sample series by changing the deposition pressure from 533 to 1067 Pa. The samples were then characterized by X-ray photoelectron spectroscopy, spectroscopic ellipsometry, Raman spectroscopy, aberration-corrected high-resolution transmission electron microscopy, selected-area electron diffraction, and a specialized plasmon imaging method. We found that the material changed with increasing pressure from predominantly amorphous silicon monoxide to silicon dioxide containing nanocrystalline silicon. The nanostructure changed from amorphous silicon filaments to nanocrystalline silicon filaments, which were found to cause anisotropic electron transport.
Mit diesem Beitrag soll der Einsatz von iBeacons als Basis eines Indoor-Ortungssystems in der Hochschulbibliothek der Technischen Hochschule Wildau vorgestellt werden. Für die Ortung innerhalb von Gebäuden sind bisher unterschiedliche Strategien zum Einsatz gekommen. Die von Apple Inc. entwickelte iBeacon-Technologie kommuniziert über Bluetooth Low Energy (BLE) und setzt somit eine Technologie ein, die einen großen Kreis von Nutzern erreicht. Als wesentlicher Teil der Campus-App Unidos Wildau operiert das Ortungssystem auf der Basis des Kartendienstes iCampus Wildau Maps. Gemachte Erfahrungen mit der iBeacon-Technologie werden ebenso im Fokus dieses Beitrags stehen wie Ergebnisse der Implementierung unseres Ortungssystems sowie Pläne für die Weiterentwicklung.
Long term studies, focusing on population- and socio-biology research, require the unequivocal identification of individuals. DNA studies with Short Tandem Repeats (STR loci) became a widespread tool in population genetics. We used the next-generation sequencing (NGS) approach with 454 shot-gun pyrosequencing to identify 13 new polymorphic STR loci for the Common Tern, Sterna hirundo. To enlarge the marker set we added two more loci originally developed for Black-legged Kittiwake (Rissa tridactyla) and Red-billed Gull (Chroicocephalus scopulinus) and arranged these 15 loci into three multiplex PCR panels for high throughput genotyping. Loci characterization demonstrated that our marker set is of high quality. A PIC value of about 0.67 and a power of exclusion value of 0.99 were reached. Deviation from Hardy-Weinberg expectations of some loci and low frequencies for null alleles are interpreted as a result of inbreeding and founder effect in the investigated tern colony. We used a test data set of this well-studied breeding colony of Common Tern at Banter Lake, Wilhelmshaven, Germany, to perform a parentage test. Parent-chick relationships, known from the social pedigree of that colony, were compared with genetically calculated ones. In order to test our markers and the used parentage program COLONY, we conducted six competing data sets with varying completeness of included parental genotypes. By including fully sampled parent pairs of known family assignment, results were correct for nest mates, single parents and parent pairs. Our marker set provides a powerful tool to investigate life-time reproductive success and other issues of population and socio-biology for Common Terns, e.g. in the aforementioned colony monitored for decades.
The redox behavior of proteins plays a crucial part in the design of bioelectronic systems. We have demonstrated several functional systems exploiting the electron exchange properties of the redox protein cytochrome c (cyt c) in combination with enzymes and photoactive proteins. The operation is based on an effective reaction at modified electrodes but also to a large extent on the capability of self-exchange between cyt c molecules in a surface-fixed state. In this context, different variants of human cyt c have been examined here with respect to an altered heterogeneous electron transfer (ET) rate in a monolayer on electrodes as well as an enhanced self-exchange rate while being incorporated in multilayer architectures. For this purpose, mutants of the wild-type (WT) protein have been prepared to change the chemical nature of the surface contact area near the heme edge. The structural integrity of the variants has been verified by NMR and UV–vis measurements. It is shown that the single-point mutations can significantly influence the heterogeneous ET rate at thiol-modified gold electrodes and that electroactive protein/silica nanoparticle multilayers can be constructed with all forms of human cyt c prepared. The kinetic behavior of electron exchange for the mutant proteins in comparison with that of the WT has been found altered in some multilayer arrangements. Higher self-exchange rates have been found for K79A. The results demonstrate that the position of the introduced change in the charge situation of cyt c has a profound influence on the exchange behavior. In addition, the behavior of the cyt c variants in assembled multilayers is found to be rather similar to the situation of cyt c self-exchange in solution verified by NMR.