Fachbereich Ingenieur- und Naturwissenschaften
Refine
Document Type
- Conference Proceeding (5) (remove)
Year of publication
- 2019 (5) (remove)
Institute
Language
- English (5)
Has Fulltext
- yes (5)
Is part of the Bibliography
- yes (5) (remove)
Keywords
- Barium nitrate (1)
- Fabry-Perot ultrasound sensor (1)
- Kalman filter (1)
- Nd:YAG laser (1)
- Raman laser (1)
- accelerometer (1)
- endoscope (1)
- gyroscope (1)
- high power single chip LED (1)
- in vivo imaging (1)
The emission of commercial solid-state lasers is shifted by Raman lasers to selected wavelengths suitable for trace gas detection. High power Raman lasers based on Ba(NO3)2, diamond and silicon detect CO2, O3 and H2O. Raman lasers base on the physical effect of stimulated Raman scattering. Two new Raman crystals (Spodumene and LuAlO3) are investigated and their SRS-spectra is shown.
Optical-resolution photoacoustic microscopy (PAM) has been shown to enable the acquisition of high resolution (μm) functional and anatomical images. For backward-mode operation, conventional piezoelectric ultrasound transducers need to be placed far away from the signal source due to their opacity and size. This can result in reduced acoustic sensitivity. Planar Fabry-Perot polymer film interferometer (FPI) sensors have the potential to overcome this limitation since they are transparent to the excitation wavelength, can be placed immediately adjacent to the signal source for high acoustic sensitivity, and offer a broadband frequency response (0 –50 MHz). In this study, we present a high frame rate, backward-mode OR-PAM system based on a planar FPI ultrasound sensor. A ns-pulsed laser provides excitation pulses (<200 nJ, maximum pulse repetition frequency = 200 kHz, 532 nm) to generate photoacoustic waves that are detected using a planar FPI sensor interrogated at 765-781 nm. For backwardmode operation and highest acoustic sensitivity, the excitation and interrogation beams are coaxially aligned and rasterscanned. The optical transfer function of the sensor, the spatial resolution and the detection sensitivity were determined to characterise the set-up. Images of a leaf phantom and first in vivo images of zebrafish larvae were acquired. This approach will enable fast 3D OR-PAM with high resolution and high sensitivity for functional and molecular imaging applications. FPI-based ultrasound detection also has the potential to enable dual-mode optical- and acousticresolution PAM and the integration of photoacoustic imaging with purely optical modalities such as multi-photon microscopy.
Photodynamic therapy (PDT) employs light activation of tissue-localized photosensitizer in an oxygen-dependent process which initiates oxidative stress, inflammation, and cell death. Laser systems, which are mostly used in PDT as light sources can be costly and oversized. light-emitting diodes (LEDs) equipment has a high potential to simplify technical part of phototriggered therapies and to reduce its costs. We develop the LED-based system that includes the control and irradiation units. The system provides the same power density at any irradiation point. Among the advantages of the device is a possibility to change the irradiation area and tune the irradiation dose. PDT experiments with cancer cells in vitro treated with two different photosensitizers demonstrated a possibility to use the developed LED-based system as a low-cost light source in PDT.
Development of tuneable Fabry-Pérot sensors for parallelised photoacoustic signal acquisition
(2019)
Fabry-Pérot (FP) sensors have enabled high resolution 3D photoacoustic (PA) imaging in backward mode. However, raster-scanning of the interrogation laser beam across the sensor can result in slow 3D image acquisition. To overcome this limitation, parallelized PA signal acquisition can be used for which FP sensors with uniform optical thickness are required. In this work, the optical thickness is tuned a) irreversibly through the use of a photopolymer host matrix and b) actively using embedded electro-optic (EO) chromophores. Polymer spacers (5 μm) were deposited using spin coating and sandwiched between two dielectric mirrors and transparent ITO electrodes. The employed polymer guest-host system consists of an EO chromophore (2-methyl-4-nitroaniline) and poly(vinyl cinnamate). EO tuneability was induced using contact poling and a tuneability of 68 pm was demonstrated. The optical thickness was homogenised by raster scanning a UV beam whilst varying the exposure time across a 4 mm2 detection aperture.
To improve the feasibility of endoscopic inspection processes we developed a system that provides online information about position, orientation and viewing direction of endoscopes, to support the analysis of endoscopic images and to ease the operational handling of the equipment. The setup is based on an industrial endoscope consisting of a camera, various MEMS and multimodal data fusion. The software contains algorithms for feature and geometric structure recognition as well as Kalman filters. To track the distal end of the endoscope and to generate 3D point cloud data in real time the optical and photometrical characteristics of the system are registered and the movement of the endoscope is reconstructed by using image processing techniques.