Refine
Document Type
- Article (7)
- Conference Paper (1)
Institute
Language
- English (8)
Has Fulltext
- yes (8)
Is part of the Bibliography
- yes (8)
Keywords
- photoswitch (2)
- silicon photonics (2)
- volumetric 3D printing (2)
- 3D chip stacking (1)
- Fourier transforms (1)
- Gaussian beam (1)
- ICP-DRIE (1)
- Nd:YAG laser (1)
- Raman laser (1)
- biogas process monitoring (1)
Xolography is a volumetric 3D printing technology utilizing two different wavelengths of light to produce objects with micrometer resolution and excellent surface quality within minutes. Dual-color photoinitiators (DCPIs) are crucial for spatial control of polymerization. However, their performance has mainly been assessed indirectly by evaluating printed objects. In this study, we present a methodology using in situ Raman spectroscopy to characterize the dual-color curing response of a representative spiropyran-based DCPI in a methacrylate-based resin composition. A dual-wavelength irradiation setup has been developed to monitor the degree of curing (DoC) as a function of the applied light doses, providing quantitative, real-time insights into bond conversion and polymerization kinetics, as well as enabling the Xolography process window to be derived. The DCPI exhibited a contrast of 89%, showing improved performance compared to first generation systems, while its efficiency was benchmarked against a benzophenone reference. Spatially resolved Raman mapping of volumetric test prints revealed DoC gradients ranging from 40% to 80% directly after printing. We demonstrate that subsequent posttreatments can eliminate these nonuniformities, increasing the DoC to > 90%. This approach provides a framework for evaluating novel dual-color photoinitiator systems, facilitating the rational design of resins, illumination protocols and optimized configurations for volumetric 3D printing.
The scaling limitations of electrical interconnects are driving the demand for efficient optical chip-to-chip links. We report the first monolithic integration of air-clad optical through-silicon waveguides in silicon, fabricated via Bosch and cryogenic deep reactive-ion etching. Rib, single-bridge, and double-bridge designs with 50 μm cores and up to 150 μm propagation lengths have been evaluated. Cryogenic-etched rib waveguides achieve the highest median transmission (66%, −1.80 dB), compared to Bosch-etched ribs (62%, −2.08 dB). Across all geometries, 3 dB alignment windows range from 9.3 μm to 49.2 μm, with Bosch-etched double-bridge waveguides providing the broadest tolerance. We show that geometric fidelity outweighs sidewall roughness for transmission and alignment in these large-core, multimode optical through-silicon waveguides. This technology provides a scalable, complementary metal-oxide semiconductor-compatible pathway toward 3D photonic interconnects.
Spatially confined photo-excitation with the lowest possible activation of the remaining volume is of central importance for high-resolution high-density optical data storage, fluorescence microscopy, 3D-lithography, and 3D-printing. Two-photon absorption (2PA) enables such applications yet leads to slow processing speed due to the underlying non-linear absorption process. Here, Split-Aperture Xolography (SAX), is introduced which uses stepwise excitation of dual-color responsive molecules to initiate a linear volumetric photo-reaction process that is up to several orders of magnitude more efficient than 2PA. The capabilities of SAX are investigated in a scenario study for focusing systems with high numerical aperture (NA) using a Python implementation of vectorial diffraction theory. The intersecting half-cones generated by the split illuminated entrance aperture of the objective reduce the axial focal spot size of the activation distribution by up to a factor of two compared to 2PA targeting the same electronic transition. A steep average decline of the activation probability with the fifth power away from focus is found for a wide range of directions. This is significantly better in comparison to 2PA and prevents that undesired out-of-focus excitation events sum-up with subsequent irradiations. This approach is expected to be advantageous for volumetric methods at the nanoscale.
We report on the design and performance of two solid-state Raman lasers, pumped by a frequency-doubled Nd:YAG laser at 532 nm (8 ns FWHM, 10 Hz, up to 10 mJ), that generate either the first or second Stokes radiation with wavelengths of 563 nm and 598 nm. Barium nitrate crystals with a 1 cm² face area and lengths of 3 cm and 5 cm were used as the Raman-active medium in stable semi-spherical resonators. The Raman lasers produced first Stokes and second Stokes pulses, achieving pulse energies up to 2.3 mJ and conversion efficiencies up to 35% (first Stokes, 5 cm crystal) and 21% (second Stokes, 5 cm crystal). The output beams exhibit nearly Gaussian profiles with beam quality factors of M² = 1.67 and M² = 1.83, respectively. The proposed design and characterization demonstrated a Raman laser with high efficiency and superior beam quality. After subsequent frequency doubling, the output appears well dedicated for future differential absorption LiDAR (DIAL) applications.
In the context of an ever-growing volume of data generated by established and emerging technologies, such as 5G, the Internet of Things, artificial intelligence, machine learning, blockchain, and virtual reality, faster communication speed is demanded by data centers and high-performance computing. Transceiver requirements surged from 100 to 400 Gb/s and beyond. In this scenario, photonics aims to enable Tb/s optical communication at energies below 1 pJ/bit. Targeting higher communication rates while maintaining a low power budget can significantly benefit from 3D photonic chip architectures. This paper presents the simulation-based design, fabrication, and characterization of a monolithically integrated optical through-silicon waveguide that facilitates the connection between different surfaces of a silicon chip. Deep reactive ion etching was employed in both the Bosch and Cryogenic variants to evaluate the effect of sidewall roughness on propagation losses. The mechanical stability of the waveguide was ensured by interrupting the annular trench with a bridging structure. The high-refractive-index contrast to air provides tight light confinement for a core size of up to 50 μm and multimode operation at 1550 nm. The morphology was characterized using scanning electron microscopy (SEM), and optical transmission characterization was performed using relative power loss measurements. A tunable laser source was buttcoupled to a waveguide to analyze light transmission efficiency. Preliminary measurements using single-mode fiber show that the transmitted values exceeded 99% for all structures.
Continuous in situ monitoring of ammonia in bioprocesses using a novel scattering fiber-optic sensor
(2026)
This study presents a laboratory proof-of-concept for a novel scattering-based fiber-optic sensor for continuous in situ monitoring of free NH3 in highly loaded aqueous bioprocess media. The sensing element consists of a thin phenyl-modified sol–gel coating with covalently immobilized bromocresol green on fused silica fiber rods. The experimental observations are consistent with covalent immobilization of the dye within the hybrid matrix, which appears to suppress classical pH-dependent indicator behavior and enables a largely pH-independent response within the biogas-relevant range of 6.8–8.5. Nanoscale structural inhomogeneities within the high-refractive-index sol–gel layer are expected to contribute to weak light scattering and to enhance the effective optical interaction length. Upon exposure to free NH3, the sensor shows reversible spectral changes, with the strongest response observed at 748 nm. The sensor exhibited an exponentially saturating calibration behavior between 20 and 200 mg/L free NH3 at 24 °C, response times of t90 less than 2 min, and good reversibility over more than 50 cycles. The deliberately minimalist optical setup consists of a white LED, the coated fiber element, and a compact spectrometer. It operated at low power without reagents, membranes, or consumables and achieved an AGREE greenness score of 0.88. Preliminary tests in real biogas digestate suggest promising matrix compatibility for continuous in situ monitoring in anaerobic digestion and related nitrogen-rich bioprocesses.
We present a camera-based photoacoustic tomograph that uses planar Fabry-Perot polymer sensors with uniform optical thickness. By using a photopolymer spacer, local refractive index adjustments effectively compensate for fabrication-induced inhomogeneities, resulting in highly uniform sensors suitable for parallel, time-resolved acoustic signal acquisition. The tomograph utilizes a green-wavelength interrogation laser and a high-speed, intensified sCMOS camera. This system enables high-resolution, three-dimensional imaging of tissue phantoms in backward mode, achieving both lateral and vertical resolutions of tens of microns. While the acoustic sensitivity is currently restricted by the specifications of the sensor, laser, and camera, this method allows for rapid, wide-area, and high-resolution photoacoustic imaging without the need for mechanical and optical scanning.
Reflectometric method for measuring residual oxides in through-silicon vias for 3D chip integration
(2025)
A significant aspect of fabricating 3D chip architectures is ensuring proper contact between the different layers of the chip, which often requires removing the underside of isolation layers before filling vias with conductive material. Currently, scanning electron microscopy is the established method for investigating such structures. In this paper, we propose a rapid, non-destructive optical analysis technique for the simultaneous measurement of through-silicon vias (TSV) depths, silicon wafer thickness, and residual oxide thickness. The proposed method utilizes Fourier peak shift analysis (FPSA) of reflectance measurements in the near-infrared (1200 nm—2200 nm) spectral regions. The application of FPSA to representative samples taken from a commercial TSV integration process for MEMS and CMOS fabrication demonstrated good agreement with reference scanning electron microscopy measurements, confirming the feasibility of the method for in-line and in-situ metrology. The results indicate that FPSA has great potential for real-time process monitoring and control during 3D chip manufacturing.

