Refine
Document Type
- Article (14)
- Conference Proceeding (5)
- Part of a Book (1)
- Preprint (1)
Institute
Language
- English (21)
Has Fulltext
- yes (21)
Keywords
- AFM (1)
- CMOS (1)
- CMOS compatibility (1)
- CMOS integration (1)
- Encapsulation (1)
- Integrated optical sensors (1)
- Interchangeable sensor chip (1)
- Mach-Zehnder (1)
- Memristive devices (1)
- Optical ring resonators (1)
Silicon photonic micro-ring resonators (MRR) developed on the silicon-on-insulator (SOI) platform, owing to their high sensitivity and small footprint, show great potential for many chemical and biological sensing applications such as label-free detection in environmental monitoring, biomedical engineering, and food analysis. In this tutorial, we provide the theoretical background and give design guidelines for SOI-based MRR as well as examples of surface functionalization procedures for label-free detection of molecules.
After introducing the advantages and perspectives of MRR, fundamentals of MRR are described in detail, followed by an introduction to the fabrication methods, which are based on a complementary metal-oxide semiconductor (CMOS) technology. Optimization of MRR for chemical and biological sensing is provided, with special emphasis on the optimization of waveguide geometry. At this point, the difference between chemical bulk sensing and label-free surface sensing is explained, and definitions like waveguide sensitivity, ring sensitivity, overall sensitivity as well as the limit of detection (LoD) of MRR are introduced. Further, we show and explain chemical bulk sensing of sodium chloride (NaCl) in water and provide a recipe for label-free surface sensing.
The possibility of exploiting the enormous potential of graphene for microelectronics and photonics must go through the optimization of the graphene–metal contact. Achieving low contact resistance is essential for the consideration of graphene as a candidate material for electronic and photonic devices. This work has been carried out in an 8′′ wafer pilot-line for the integration of graphene into a CMOS environment. The main focus is to study the impact of the patterning of graphene and passivation on metal–graphene contact resistance. The latter is measured by means of transmission line measurement (TLM) with several contact designs. The presented approaches enable reproducible formation of contact resistivity as low as 660 Ω μm with a sheet resistance of 1.8 kΩ/□ by proper graphene patterning, passivation of the channel and a post-processing treatment such as annealing.
Label-free direct-optical biosensors such as surface-plasmon resonance (SPR) spectroscopy has become a gold standard in biochemical analytics in centralized laboratories. Biosensors based on photonic integrated circuits (PIC) are based on the same physical sensing mechanism: evanescent field sensing. PIC-based biosensors can play an important role in healthcare, especially for point-of-care diagnostics, if challenges for a transfer from research laboratory to industrial applications can be overcome. Research is at this threshold, which presents a great opportunity for innovative on-site analyses in the health and environmental sectors. A deeper understanding of the innovative PIC technology is possible by comparing it with the well-established SPR spectroscopy. In this work, we shortly introduce both technologies and reveal similarities and differences. Further, we review some latest advances and compare both technologies in terms of surface functionalization and sensor performance.
Comprehensive diagnostics is a prerequisite for the application of graphene in semiconductor technologies. Here, the authors present long-term investigations of graphene on 200-mm Ge(100)/Si(100) wafers under clean room environmental conditions. Diagnostic of graphene was performed by a fast and nondestructive metrology method based on the combination of spectroscopic ellipsometry and reflectometry (SE/R), realized within a wafer optical metrology tool. A robust procedure for unambiguous thickness monitoring of a multilayer film stack, including graphene, interface layer GeOx underneath graphene, and surface roughness is developed and applied for process control. The authors found a relationship between the quality of graphene and the growth of GeOx beneath graphene. Enhanced oxidation of Ge beneath graphene was registered as a long-term process. SE/R measurements were validated and complemented using atomic force microscopy, scanning electron microscopy, Raman spectroscopy, and secondary ion mass spectrometry. This comparative study shows a high potential for optical metrology of graphene deposited on Ge/Si structures, due to its great sensitivity, repeatability, and flexibility, realized in a nondestructive way.
From Lab-on-chip to Lab-in-App: Challenges towards silicon photonic biosensors product developments
(2022)
This work presents and evaluates different approaches of integrated optical sensors based on photonic integrated circuit (PIC) technologies for refractive index sensing. Bottlenecks in the fabrication flow towards an applicable system are discussed that hinder a cost-effective mass-production for disposable sensor chips. As sensor device, a waveguide coupled micro-ring based approach is chosen which is manufactured in an 8” wafer level process. We will show that the co-integration with a reproducible, scalable and low-cost microfluidic interface is the main challenge which needs to be overcome for future application of silicon technology based PIC sensor chips.
Recent developments in optical biosensors based on integrated photonic devices are reviewed with a special emphasis on silicon-on-insulator ring resonators. The review is mainly devoted to the following aspects: (1) Principles of sensing mechanism, (2) sensor design, (3) biofunctionalization procedures for specific molecule detection and (4) system integration and measurement set-ups. The inherent challenges of implementing photonics-based biosensors to meet specific requirements of applications in medicine, food analysis, and environmental monitoring are discussed.
The resistive switching properties of HfO₂ based 1T-1R memristive devices are electrically modified by adding ultra-thin layers of Al₂O₃ into the memristive device. Three different types of memristive stacks are fabricated in the 130 nm CMOS technology of IHP. The switching properties of the memristive devices are discussed with respect to forming voltages, low resistance state and high resistance state characteristics and their variabilities. The experimental I–V characteristics of set and reset operations are evaluated by using the quantum point contact model. The properties of the conduction filament in the on and off states of the memristive devices are discussed with respect to the model parameters obtained from the QPC fit.
The two main features of the memristive devices which makes them the promising candidates for neuromorphic applications are low power consumption and CMOS compatibility. The monolithic integration of memristive devices with CMOS circuitry paves the way for in-memory computing. This chapter focuses on the factors governing the CMOS integration process. Firstly, the influence of CMOS baseline technology selection on the memristor module is briefly discussed. Secondly, the selection of metal level interconnects and their effect on the memristive device performance is explained. Further, the widely used deposition technique for the CMOS compatible memristive switching layers is presented. Finally, the implementation of the optimized process for the fabrication of the memristive module and its influence on the device performance is presented in terms of electrical characterization results.
In this work, we analyze a horizontal slot waveguide configuration, which evaluates the potential for an integration of barium titanate (BTO) based modulators into a photonic integrated circuit (PIC) technology based on siliconon- insulator (SOI) wafer. The waveguide configuration consists of a doped crystal silicon layer, a Ba0:7Sr0:3TiO3 (BST) template layer, a barium titanate (BTO) layer and a doped poly-silicon layer on top. In contrast to current approaches, we analyze the performance of this waveguide-structure by using a vertical electrode configuration that is formed by the doped silicon layer. In this way, the electric field strength is dramatically increased compared to current horizontal electrode configuration.
We report on the direct observation and simultaneous use of the linear and quadratic electro-optical effect and propose a method by which higher-order susceptibilities of electro-optical materials can be determined. The evaluation is based on the separation of the second- and third-order susceptibilities and the experimental technique uses a slot waveguide ring resonator fabricated in integrated photonic circuit technology, which is embedded by a guest-host polymer system consisting of the azobenzene dye Disperse Red 1 in a poly(methyl methacrylate) matrix as an active electro-optical material. The contribution of both effects on the electro-optical response under the influence of static and time-varying electrical fields is investigated. We show that the quadratic electro-optical effect has a significant influence on the overall electro-optical response even with acentric molecular orientated molecules. Our findings have important implications for developing electro-optical devices based on polymer-filled slot waveguides and give rise to advanced photonic circuits.