TY - THES A1 - Marehn, David Thomas T1 - Reliability of Data Acquisition and Processing Approaches for Chromatography Detection Systems in Pharmacy N2 - Nowadays pharmaceutical analysis and industry could not be imagined without using chromatographic methods like the High Performance Liquid Chromatography (HPLC) and Gas Chromatography (GC). Therefore, the field of chromatography is already firmly anchored in the three important, regional pharmacopeias: EP, USP and JP. Deficits of specifications within these pharmacopoeias relating to the detector parameters sampling rate and signal filtration are the major motivation of this thesis. Furthermore investigations on the data acquisition and processing within the detectors and software products dealing with collected data were done. Several concepts like double entry method, smoothing optimization and signal filtration based on persistence have been developed and are used as tools to examine the data integrity of commercial Chromatography Data System (CDS), improve the signal-to-noise ratio of small peaks to lower the LOD and LOQ by efficient denoising, and determine the suitable filter parameters and sampling rates an user can apply on his system to accelerate the method development and validation. All developments have been tested on simulated and real chromatograms and have shown that they are suitable for their specific purposes. In the end optimizations in the concepts still exist but some new aspects in the long-term investigated field of chromatography have been discovered. KW - sampling rate KW - chromatography KW - signal filtration Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:526-opus4-15438 ER - TY - JOUR A1 - Marehn, David Thomas A1 - Wilhelm, Detlef A1 - Pospisil, Heike A1 - Pizzoferrato, Roberto T1 - Double entry method for the verification of data a chromatography data system receives JF - Journal of Sensors and Sensor Systems N2 - The importance of software validation increases since the need for high usability and suitability of software applications grows. In order to reduce costs and manage risk factors, more and more recommendations and rules have been established. In the field of pharmacy the vendors of so-called chromatography data systems (CDSs) had to implement the guidelines of the Code of Federal Regulations Title 21 (CFR 21) during the last few years in order to fulfill the increasing requirements. The CFR 21 part 11 deals with electronic records and signatures. This part is binding for each company in the regulated environment that wishes to create, edit and sign electronic information instead of printing them on paper. Subsection CFR 21 part 11.10(h) explains how to perform an input check for manual user entries as well as for data that will be collected from an external device. In this article we present an approach performing the double entry method on data provided by the hardware instrument in order to investigate possible influences on the raw data by the handling CDS. A software tool has been written which allows us to communicate with a high-performance liquid chromatography (HPLC) detector and acquire data from it. The communication is completely independent of a CDS which is started separately and connected to the same system. Using this configuration we made a parallel data acquisition of two instances at the same time possible. Two CDSs have been tested and for at least one of them it has been shown that a comparison of the acquired data can be done as with the double entry method for the data verification. For the second CDS we checked whether it would be applicable after a few modifications. The given approach could be either used for a live data verification of produced raw data or as a single test during a software operational qualification to verify the data acquisition functionality of the software. Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:526-opus4-12349 SN - 2194-878X VL - 8 SP - 207 EP - 214 ER -