Refine
Year of publication
Document Type
- Conference Proceeding (37)
- Article (peer reviewed) (4)
- Contribution to a Periodical (3)
- Part of a Book (2)
- Report (1)
Is part of the Bibliography
- no (47)
Keywords
- Microelectronics (6)
- fluorescence (6)
- Fluorescence lifetime imaging (5)
- Diode lasers (4)
- FD-FLIM (4)
- Fluoreszenz (4)
- Phase shift (4)
- Fluorescence (3)
- Image processing algorithms (3)
- polymer (3)
Today, the automatic separation of polymers from each other in an industrial scale is an unsolved problem. In laboratory environments, two methods are known whereby plastic is sorted either by color or by fluorescence decay time measurements that require fast synchronization and thus expensive equipment. A simple and pragmatic process is proposed to separate plastics from each other: all fluorescent photons are counted in relation to the absorbed photons. A theoretical model and an experimental setup are built in order to determine an apparatus specific quantum efficiency.
The fluorescence decay time allows to identify and distinguish polymers from each other. Three differently treated biaxially-oriented polyethylene terephthalate films are examined with two excitation wavelengths of 445 and 488nm. The fluorescence decay time is dependent of the treatment method of the films and is a means for identification.
Nowadays, fluorescence lifetime measurements and the method of fluorescence lifetime imaging are already state of the art in biomedical research. Also first investigations show that polymers could be identified due to their endogenous fluorescent lifetime. Thus an approach of identifying polymers with fluorescence lifetime imaging is done in this contribution. Therefore, four different polymers are examined and evaluated with statistical methods in order to determine their specific fluorescence lifetimes.
Plastic waste is one of the biggest growing factors contributing to environmental pollution. So far there has been no established method to detect and identify plastics in environmental matrices. Thus, a method based on their characteristic fluorescence behavior is used to investigate whether plastics can be detected and identified in tap water under laboratory conditions. The experiments show that the identification of plastics as a function of water depth is possible. As the identification becomes more difficult with higher water depths, investigations with a highly sensitive imaging method were carried out to obtain an areal integration of the fluorescent light and thus better results.
Die wohl größte aktuelle Umweltverschmutzung mit Kunststoffen findet in Ozeanen, Seen und Flüssen statt. Bis jetzt gibt es kein etabliertes Verfahren, mit dem Kunststoffe in Umwelt- bzw. Wassermatrizen detektiert werden können. Deshalb wird mit einem Verfahren, welches auf dem Prinzip der Fluoreszenz basiert, untersucht, ob unter Laborbedingungen Kunststoffe in Wasser detektiert und identifiziert werden können. Anhand eines mathematischen Modells, einer Simulation und mit Hilfe von optischen Experimenten wird gezeigt, dass der Nachweis und auch eine Identifikation von Kunststoffen in Abhängigkeit der Wassertiefe, mit diesem Verfahren möglich ist.