Correlations between standardised and real impact sound sources in lightweight wooden structures
(2021)
This study aimed to understand the correlation between standard impact sound sources and real impact sources in lightweight floor structures. Six real impact sources (adult walking, child running, child jumping on the floor, and three objects falling) were used to be compared with standard impact sources (i.e. tapping machine and impact ball). Measurements were conducted on a lightweight timber joist floor. Impact sound pressure levels (SPLs) produced by the standard impact sources were measured on the four floor structures with or without carpet tiles. For the real impact sources, two walkers wearing socks and slippers walked at different speeds (normal and fast) along three paths, while two children ran along the three paths and jumped at four positions. Also, the SPLs generated by dropped objects were measured at five positions. Seven standardised single-number quantities (SNQs) were calculated for the tapping machine and the impact ball, while three noise ratings (LAeq, LAFmax, and LN) were also computed from the sound recordings of the real impact sources. Both the tapping machine and the impact ball showed similar frequency characteristics with the real impact sources across all the floor structures. All the SNQs for the tapping machine and the impact ball were highly correlated with the energy-based noise ratings of the adult walking and little differences were found across walking speeds and footwear. Similar tendencies were observed from other real impact sources, indicating the high correlations between the standardised SNQs of the tapping machine and the impact ball and the noise ratings.
This paper concerns the development and validation of Finite Element Methods (FEM) to simulate the dynamic response of a dowelled-joist timber floor. This is a solid floor comprised of timber joists connected using timber dowels with individual assemblies connected using inclined metal screws. The focus is on the structural dynamics in the low-frequency range up to 200 Hz which is the relevant range for impact sound insulation and vibration serviceability. Dowel connections between the joists that formed each assembly were modelled using either rigid or spring connectors in the FEM models. The validation against experimental modal analysis showed that both approaches were valid in terms of the eigenfrequencies, Modal Assurance Criterion (MAC) and the spatial-average velocity with point excitation. Whilst the FEM model with spring connectors had a higher number of correlated modes in the MAC analysis, this required removal of many spurious modes before predicting the response. The validated models were used to demonstrate the potential in predicting assessment parameters for vibration serviceability that are contained in EN 1995-1-1 (Eurocode 5). This predictive approach to the evaluation of vibration serviceability has the advantage in that it can be used for non-standard timber floors with non-standard boundary conditions or floor plans.
With the increasing mechanization of buildings, it is necessary to be able to predict both the structure-borne sound power input from building machinery and the subsequent propagation of structure-borne sound in the building. This paper considers lightweight constructions and describes the results of an experimental study in the laboratory on a T-junction that was constructed from a timber joist floor and two double leaf timber-frame walls. The focus in this paper is on the vibrational behaviour of one of the timber-frame walls. To assess the vibration pattern and the propagation of structure-borne sound, the surface velocity levels were measured on a grid on both leaves of the wall with point force excitation on one side. This grid allowed calculation of structural intensity vectors. The influence of elements such as the timber studs and tongue and grooved joints between the boards were apparent in different frequency regions. Experimental modal analysis was carried out using measurements on both leaves of the wall, giving information about the coupling in different frequency regions. The results give insight into how such a timber-frame wall could be modelled using statistical energy analysis.
It is common for timber ceiling constructions to include a suspended ceilings made of plasterboard. In order to minimize the radiation from impact excitation, especially in the low frequency range below 100 Hz, a detailed analysis of the vibration behaviour was necessary.
An experimental modal analysis was carried out and the radiated sound power from the suspended ceiling was measured using a sweep sine excitation by a shaker connected to the top layer of the timber floor construction.
Since the experimental modal analysis was conducted using a high frequency resolution and with a non-stationary sound field, it was necessary to check the validity of the intensity measurements by comparing it with 1/3-octave band measurements. The results show very good agreement.
By this means the radiation efficiency can be measured simultaneously with an experimental modal analysis of a structure.
Measured transmission functions from structure-borne sound sources in a timber-frame construction
(2015)
The aim of prEN 15657-2 is to provide engineering methods to estimate the structure-borne sound power input from machinery in situations where the source mobility matches or is lower than the receiver mobility. This situation often affects lightweight constructions such as timber-frame buildings. To estimate the sound pressure level in a room that is adjacent or distant from the room containing the source, the installed structure-borne sound power has to be propagated across at least one junction in the timber-frame construction. However, at present there are no generic, validated calculation models due to the complexity and the large variety of timber-frame constructions. A simplified approach to investigate and compare the structure-borne sound transmission is to treat the framed construction as a black box and only consider one parameter, a transmission function which is the ratio of the sound pressure level in the receiving room to the injected structure-borne sound power level. To get information about the variation of this transmission function in different timber-frame constructions, measurements were made in both the laboratory and the field. Experimental results are presented showing the variation due to different building configurations and the effect of the excitation position on the transmission function.
This paper concerns the modelling of sound transmission across a timber-frame wall under mechanical excitation by a point force using Statistical Energy Analysis (SEA). The aim is to develop and experimentally validate a model that would be relevant to machinery such as a heating device or a ventilation system that are often connected to such walls. The prediction is compared against measurements on a wall that forms part of a lightweight test-rig in the Laboratory for Sound Measurement (LaSM) at the University of Applied Sciences Rosenheim. A basic timber frame was built with a single layer of tongue and grooved chipboard on each side of the wall. With this configuration the structure represented a lightweight construction with horizontal junctions in addition to the vertical junctions that are more typical with lightweight constructions formed from plasterboard. A series of SEA models were developed with an increasing degree of complexity regarding the partitioning of the structure into subsystems. Additional experimental work was carried out to determine coupling loss factors across the chipboard joints which were then incorporated in the model. The SEA predictions are compared with measured velocities on both leaves and sound pressure levels in the cavities.