<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>1734</id>
    <completedYear>2012</completedYear>
    <publishedYear/>
    <thesisYearAccepted/>
    <language>deu</language>
    <pageFirst>153</pageFirst>
    <pageLast>165</pageLast>
    <pageNumber>4</pageNumber>
    <edition/>
    <issue>4</issue>
    <volume>34</volume>
    <type>contributiontoperiodical</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="deu">Untersuchung des Gesamtenergiedurchlassgrades an gebäudeintegrierbaren, teiltransparenten Photovoltaik- Modulen bei elektrischer Leistungsentnahme</title>
    <abstract language="deu">Der Gesamtenergiedurchlassgrad (g-Wert) verschiedener teiltransparenter,&#13;
gebäudeintegrierbarer Photovoltaik-Module wurde&#13;
mit und ohne Entnahme elektrischer Leistung kalorimetrisch gemessen.&#13;
Durch die Leistungsentnahme sinkt die Oberflächentemperatur&#13;
des Moduls um bis zu 4 K. Gleichzeitig reduziert sich der&#13;
g-Wert aufgrund der geringeren sekundären Wärmeabgabe. Die&#13;
Größe der Abnahme hängt von der entnommenen Leistung ab&#13;
und stimmt sehr gut mit einem einfachen, auf dem Energiesatz&#13;
basierenden Rechenmodell überein.</abstract>
    <abstract language="eng">Investigation of the total solar energy transmittance on buildingintegrated,&#13;
semitransparent photovoltaic modules with and without&#13;
extraction of electrical power. The total solar energy transmittance&#13;
(g-value) of different building-integrated PV-elements&#13;
has been measured with and without extracting electrical power&#13;
from the module. When extracting energy, a reduction in the gvalue&#13;
has been measured. Moreover, a reduction in temperature&#13;
up to 4 K on the inner surface is observed. The experimental results&#13;
are in very good agreement with a physical model based on&#13;
energy conservation.</abstract>
    <parentTitle language="deu">Bauphysik</parentTitle>
    <identifier type="url">https://doi.org/10.1002/bapi.201200019</identifier>
    <enrichment key="RS_Correlation">Ja</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <author>Claudia Schäfle</author>
    <author>Christine Lux</author>
    <author>Franz Feldmeier</author>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>g-Wert</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Photovoltaik</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Building-integrated PV-modules</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>total solar energy transmittance</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>building physics</value>
    </subject>
    <collection role="institutes" number="">Fakultät für Angewandte Natur- und Geisteswissenschaften</collection>
    <thesisPublisher>Technische Hochschule Rosenheim</thesisPublisher>
  </doc>
</export-example>
